AllureRecalls & reported problems across all models
St. Jude Medical, Inc. · 2 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 474
- Deaths reported
- 8
- Injuries reported
- 199
- Recalls
- 0
We found 2 models of Allure by St. Jude Medical, Inc. in the FDA's device registry (GUDID). Together they are named in 474 adverse event reports in the FDA's MAUDE database, received between Jun 11, 2018 and Sep 30, 2026 — classified as 8 deaths, 199 injuries, 267 malfunctions.
The most frequently reported specific device problem is “Defective Device” (81 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Most reported Allure problems
Device problems
- Adverse Event Without Identified Device or Use Problem130
- Defective Device81
- Premature Discharge of Battery54
- Over-Sensing38
- Pacemaker Found in Back-Up Mode23
- Failure to Interrogate22
- Pacing Problem18
- Failure to Capture16
Patient problems
- No Clinical Signs, Symptoms or Conditions165
- Unspecified Infection96
- Insufficient Information95
- No Known Impact Or Consequence To Patient57
- Pocket Erosion34
- Discomfort15
- Arrhythmia10
- No Consequences Or Impact To Patient9
Allure models
2 models, most reported first. Each model has its own page with its reports, recalls and device details.
- Allure™ PM3222Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D)8 deaths463 reports
- Allure™ PM3120Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D)11 reports
Recent Allure adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionSep 30, 2026Loose or Intermittent Connection
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50954833 ↗InjurySep 30, 2026Adverse Event Without Identified Device or Use Problem
It was reported that the patient experienced heart failure and complete heart block. It was noted that the implanted pacemaker eroded through the skin. During the device exchange procedure, it was observed that the left ventricular (LV) lead was fractured. The LV lead was capped and the pacemaker was explanted and replaced on (b)(6) 2026. The patient was in stable condition.
Patient problems: Pocket Erosion
MAUDE report 50942445 ↗MalfunctionSep 29, 2026Capturing Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50928360 ↗InjurySep 10, 2026Premature Discharge of Battery
During an in-clinic follow-up, the longevity of the device was shorter than anticipated. Premature battery depletion is suspected, although not confirmed. The device was explanted and replaced to resolve the event. The patient is stable.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50715276 ↗MalfunctionSep 8, 2026Incorrect, Inadequate or Imprecise Result or Readings
It was reported that a remote alert was received, however no electrograms were received. No intervention has been performed. The patient is stable with no consequences.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50659990 ↗MalfunctionSep 3, 2026Connection Problem
During implant, the atrial lead was unable to be securely connected to the device. The device was explanted and replaced to resolve the event and the patient was stable.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50587186 ↗InjurySep 1, 2026Adverse Event Without Identified Device or Use Problem
It was reported that the patient presented to the clinic due to a pocket infection. The physician explanted the pacemaker and replaced it with a leadless pacemaker on (b)(6) 2026. The patient was in stable condition.
Patient problems: Unspecified Infection
MAUDE report 50536502 ↗MalfunctionAug 24, 2026Pacing Problem
During an in-clinic follow-up, automatic mode switch (AMS) was observed on the right atrial (RA) lead and device. No intervention has been performed to resolve the event. The patient is currently stable and will continue to be monitored.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50408180 ↗InjuryAug 20, 2026Adverse Event Without Identified Device or Use Problem
It was reported that the patient presented to the hospital with device erosion through the skin at the pacemaker pocket site. The pacemaker, right atrial lead, right ventricular lead, and left ventricular lead were subsequently explanted and replaced. The patient remained in stable condition throughout the procedure.
Patient problems: Pocket Erosion
MAUDE report 50339213 ↗InjuryAug 17, 2026Insufficient Device Problem Information
It was reported that the patient presented for a pacemaker exchange procedure. It was noted that a replacement pacemaker was implanted and explanted on the same procedure day due to unknown reason. A new pacemaker was implanted. The patient's status was not provided.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50268689 ↗MalfunctionAug 13, 2026Data Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50241583 ↗MalfunctionAug 7, 2026Data Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50168808 ↗InjuryAug 6, 2026Adverse Event Without Identified Device or Use Problem
It was reported that the patient presented to the hospital with a localized pocket infection at the device implantation site. Due to the infection, the physician elected to explant the pacemaker and the right ventricular (RV) lead on (b)(6) 2026. A replacement procedure was subsequently performed on (b)(6) 2026. The patient was in stable condition.
Patient problems: Unspecified Infection
MAUDE report 50153016 ↗MalfunctionJul 1, 2026No Apparent Adverse Event
THIS REPORT IS TO ADVISE OF AN EVENT OBSERVED DURING ANALYSIS.
Patient problems: Insufficient Information
MAUDE report 25674343 ↗MalfunctionApr 30, 2026No Apparent Adverse Event
THIS REPORT IS TO ADVISE OF AN EVENT OBSERVED DURING ANALYSIS.
Patient problems: Insufficient Information
MAUDE report 25047524 ↗
Other St. Jude Medical, Inc. products
- Tendril15 models · 49,498 reports
- Octrode10 models · 36,740 reports
- Proclaim12 models · 35,038 reports · 17 recalls
- Durata28 models · 19,805 reports
- Assurity MRI2 models · 17,838 reports · 1 recall
- Gallant8 models · 12,885 reports · 5 recalls
- Quartet10 models · 11,001 reports
- MitraClip19 models · 9,056 reports · 2 recalls
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page