CLEARLINK/BURETROLRecalls & reported problems across all models
Baxter Healthcare Corporation · 4 models in the FDA device registry
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 34
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls
- 0
We found 4 models of CLEARLINK/BURETROL by Baxter Healthcare Corporation in the FDA's device registry (GUDID). Together they are named in 34 adverse event reports in the FDA's MAUDE database, received between Mar 15, 2018 and Sep 25, 2026 — classified as 34 malfunctions.
The most frequently reported specific device problem is “Fluid/Blood Leak” (9 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Most reported CLEARLINK/BURETROL problems
Device problems
- Fluid/Blood Leak9
- Air/Gas in Device5
- Device Operates Differently Than Expected5
- Improper Flow or Infusion5
- Detachment of Device or Device Component4
- Material Puncture/Hole4
- Disconnection3
- Reflux within Device3
Patient problems
- No Clinical Signs, Symptoms or Conditions19
- No Consequences Or Impact To Patient8
- No Patient Involvement5
- No Known Impact Or Consequence To Patient2
CLEARLINK/BURETROL models
4 models, most reported first. Each model has its own page with its reports, recalls and device details.
- CLEARLINK/BURETROL 2C8864Set, administration, intravascular18 reports
- CLEARLINK/BURETROL 2H8864Set, administration, intravascular10 reports
- CLEARLINK/BURETROL 2H8865Set, administration, intravascular4 reports
- CLEARLINK/BURETROL 2R8864Set, administration, intravascular2 reports
Recent CLEARLINK/BURETROL adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionSep 25, 2026Backflow
It was reported that a Clearlink Buretrol Solution Set experienced medication backing up into the tubing and Buretrol during patient infusion. There was no report of patient injury or medical intervention associated with this event. No additional information is available.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50900099 ↗MalfunctionMay 26, 2026Fluid/Blood Leak
IT WAS REPORTED THAT AN UNSPECIFIED QUANTITY OF BURETROL SOLUTION SETS LEAKED AT THE ROLLER CLAMP SECTION. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25290458 ↗MalfunctionMar 6, 2026Fluid/Blood Leak; Material Puncture/Hole
IT WAS REPORTED THAT THERE WAS A HOLE IN THE TUBING OF A CLEARLINK BURETROL ADD-ON SET WHICH RESULTED IN A FLUID LEAK. WHILE PREPARING TO PRIME THE SET WITH BLOOD PRIOR TO PATIENT USE, IT APPEARED AS THOUGH THERE WAS A HOLE IN TUBING WHERE THE SLIDE CLAMP WAS WHICH RESULTED IN A LEAK. THERE WAS NO PATIENT INVOLVEMENT. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24536817 ↗MalfunctionDec 31, 2025Filling Problem; Air/Gas in Device; Filling Problem; Air/Gas in Device
IT WAS REPORTED THAT THERE WERE TWO (2) EVENTS INVOLVED WITH BURETROL ADD-ON SETS THAT HAD AIR IN THE TUBING BELOW THE BURETROL (WHICH HAD FLUID IN IT) AND BELOW THE PUMP ALTERNATING WITH FLUID. THE EVENT WAS FURTHER DESCRIBED AS "COULD HAVE BEEN AN OVER-INFUSION THAT WAS MINIMIZED BY HAVING A BURETROL, THEREBY LIMITING FLUID". THIS WAS OBSERVED DURING PATIENT INFUSION. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23936950 ↗MalfunctionDec 31, 2025Air/Gas in Device; Air/Gas in Device
IT WAS REPORTED THAT A CLEARLINK SYSTEM BURETROL SET HAD LARGE SPACES OF AIR IN THE TUBING. THE DEVICE CONTAINED DEXTROSE 5% SOLUTION. THIS WAS OBSERVED DURING AN UNSPECIFIED PROCESS STEP. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23936096 ↗MalfunctionAug 15, 2025Fluid/Blood Leak; Material Split, Cut or Torn; Fluid/Blood Leak; Material Split, Cut or Torn
IT WAS REPORTED THAT A CLEARLINK SYSTEM NON-DEHP BURETROL SOLUTION SET LEAKED AT THE AREA NEAR THE LOWEST INJECTION PORT AND DRIPPED ON THE FLOOR. THE ISSUE OCCURRED DURING PATIENT INFUSION WITH VINCRISTINE AND METHOTREXATE. THE METHOTREXATE LINE (CLAMPED AND NOT INFUSING) WAS CONNECTED TO THE VINCRISTINE PRIMARY LINE AT THE LOWEST PORT. WHEN THE VINCRISTINE HAD INFUSED 10ML, THE AREA NEAR THE LOWEST INJECTION PORT ON THE METHOTREXATE LINE LEAKED; THERE WAS A VISIBLE "KINK" AT THE LEAK LOCATION. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22816808 ↗MalfunctionAug 13, 2024No Flow; No Flow
IT WAS REPORTED THAT THERE WAS NO FLUID FLOW THROUGH AN UNSPECIFIED QUANTITY (AT LEAST FIVE) CLEARLINK BURETROL SOLUTION SETS. IT WAS OBSERVED THAT THE IV (INTRAVENOUS) SOLUTION STOPS FLOWING WITHIN A FEW MINUTES AFTER FLUSHING. THE STOPPER WAS NOT COMPRESSING OR CAUSING THE FLOW TO STOP. THE IV SOLUTION STARTS TO BACK UP, REQUIRING A SECOND FLUSH TO CONTINUE FUNCTIONING. IT WAS UNKNOWN IF A PATIENT WAS CONNECTED FOR THERAPY AT THE TIME OF THIS EVENT. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19972890 ↗MalfunctionJun 4, 2024Detachment of Device or Device Component; Air/Gas in Device; Detachment of Device or Device Component; Air/Gas in Device
IT WAS REPORTED THAT AN UNSPECIFIED QUANTITY OF CLEARLINK SYSTEM BURETROL SOLUTION SETS HAD THE FILTER VALVE SEPARATE FROM THE DRIP CHAMBER; AIR LEAKED INTO THE CHAMBER. THIS WAS OBSERVED DURING PRIMING. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19460694 ↗MalfunctionJun 4, 2024Detachment of Device or Device Component; Air/Gas in Device; Detachment of Device or Device Component; Air/Gas in Device
IT WAS REPORTED THAT AN UNSPECIFIED QUANTITY OF CLEARLINK SYSTEM BURETROL SOLUTION SETS HAD THE FILTER VALVE SEPARATE FROM THE DRIP CHAMBER; AIR LEAKED INTO THE CHAMBER. THIS WAS OBSERVED DURING PATIENT INFUSION. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19460575 ↗MalfunctionJun 4, 2024Disconnection; Fluid/Blood Leak; Disconnection; Fluid/Blood Leak
IT WAS REPORTED THAT AN UNSPECIFIED QUANTITY OF CLEARLINK BURETROL SOLUTION SETS LEAKED. THE SPIKE WOULD DISCONNECT FROM THE IV (INTRAVENOUS) BAG FROM A SMALL TUG OR MOVEMENT CAUSING MEDICATED SOLUTION (MAGNESIUM SOLUTION) TO ¿RUN OUT RAPIDLY TO THE FLOOR OR ON THE NURSES.¿ THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19460521 ↗MalfunctionJun 3, 2024Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT THE TUBING OF THREE (3) CLEARLINK SYSTEM BURETROL SOLUTION SETS COMPLETELY SEPARATED DURING PRIMING. THERE WAS NO PATIENT INVOLVEMENT. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19452721 ↗MalfunctionNov 28, 2023Fluid/Blood Leak; Material Puncture/Hole; Fluid/Blood Leak; Material Puncture/Hole
IT WAS REPORTED THAT THERE WAS A HOLE BENEATH THE CHAMBER OF AN UNSPECIFIED QUANTITY OF CLEARLINK SYSTEM BURETROL SOLUTION SETS WHICH RESULTED IN A LEAK. THE ISSUE WAS IDENTIFIED BEFORE PATIENT USE. THERE WAS NO PATIENT INVOLVEMENT. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18222533 ↗MalfunctionNov 17, 2023Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED THAT APPROXIMATELY FOUR (4) TO FIVE (5) CLEARLINK SYSTEM BURETROL SOLUTION SETS WERE LEAKING FROM AN UNSPECIFIED LOCATION. THIS WAS DISCOVERED DURING SETUP/PREPARATION PRIOR TO PATIENT USE. THERE WAS NO PATIENT INVOLVEMENT. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18164856 ↗MalfunctionNov 1, 2023Fluid/Blood Leak; Material Puncture/Hole; Fluid/Blood Leak; Material Puncture/Hole
IT WAS REPORTED THAT THERE WAS A HOLE BENEATH THE CHAMBER OF AN UNSPECIFIED QUANTITY [AT LEAST FIVE (5)] OF CLEARLINK SYSTEM BURETROL SOLUTION SETS WHICH RESULTED IN A LEAK. THE ISSUE WAS IDENTIFIED DURING USE. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18048289 ↗MalfunctionOct 12, 2023Material Puncture/Hole; Air/Gas in Device; Material Puncture/Hole; Air/Gas in Device
IT WAS REPORTED THAT A CLEARLINK SYSTEM BURETROL SOLUTION SET HAD A HOLE RIGHT BELOW THE CHAMBER OF THE TUBING WHICH RESULTED IN LARGE AMOUNTS OF AIR IN THE INTRAVENOUS LINE. IT WAS NOT SPECIFIED WHEN IN THE PROCESS STEP THIS OCCURRED. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17925866 ↗
Other Baxter Healthcare Corporation products
- EXACTAMIX28 models · 6,739 reports · 13 recalls
- MiniCap3 models · 3,423 reports · 7 recalls
- Novum IQ3 models · 1,540 reports · 7 recalls
- CLEARLINK/CONTINU-FLO/DUO-VENT3 models · 873 reports · 3 recalls
- CLEARLINK19 models · 710 reports · 4 recalls
- CLEARLINK/CONTINU-FLO8 models · 416 reports · 4 recalls
- CLEARLINK/DUO-VENT5 models · 282 reports · 1 recall
- REPEATER6 models · 189 reports
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page