Novum IQRecalls & reported problems across all models
Baxter Healthcare Corporation · 3 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
7 open recalls name at least one Novum IQ model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 1,540
- Deaths reported
- 4
- Injuries reported
- 135
- Recalls
- 7
We found 3 models of Novum IQ by Baxter Healthcare Corporation in the FDA's device registry (GUDID). Together they are named in 1,540 adverse event reports in the FDA's MAUDE database, received between Oct 5, 2023 and Sep 25, 2026 — classified as 4 deaths, 135 injuries, 1,401 malfunctions.
The most frequently reported specific device problem is “Filling Problem” (397 reports).
7 FDA recall records name at least one of these models by its device identifier, 7 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Novum IQ recalls
FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.
- Aug 11, 2026Open, Classified
A software issue that may occur during a Volume/Time (VOT) multi-syringe infusion when a syringe reaches empty and is replaced while a Volume To Be Infused (VTBI) remains.
Z-3066-2026 · Root cause: Software design · Recall details · FDA record ↗
- Aug 11, 2026Open, Classified
A software issue that may occur during a Volume/Time (VOT) multi-syringe infusion when a syringe reaches empty and is replaced while a Volume To Be Infused (VTBI) remains.
Z-3065-2026 · Root cause: Software design · Recall details · FDA record ↗
- Aug 4, 2025Open, Classified
Baxter Healthcare Corporation is issuing an Urgent Medical Device Correction for the Novum IQ Large Volume Pump (LVP) and Novum IQ Syringe Pump (SP) due to software anomalies that may result in a blank Run screen (LVP and SP) and/or false motor movement system error (SP only).
Z-2333-2025 · Root cause: Software design (manufacturing process) · Recall details · FDA record ↗
- Aug 4, 2025Open, Classified
Baxter Healthcare Corporation is issuing an Urgent Medical Device Correction for the Novum IQ Large Volume Pump (LVP) and Novum IQ Syringe Pump (SP) due to software anomalies that may result in a blank Run screen (LVP and SP) and/or false motor movement system error (SP only).
Z-2332-2025 · Root cause: Software design (manufacturing process) · Recall details · FDA record ↗
- Jul 14, 2025Open, Classified
Baxter is issuing an Urgent Medical Device Correction for the Novum IQ large volume pump (LVP) due to the potential for underinfusion when transitioning from a flow rate to a higher flow rate that is more than double. (e.g., rate change or bolus). The level of underinfusion is variable based on the current infusion rate, the duration the pump has been running at this flow rate, and the magnitude of the rate change. The longer the duration the pump has been running at the current infusion rate and the larger the magnitude of the rate change, the larger the underinfusion that would be experienced. Additionally, Baxter has identified an increase in customer reports of over and underinfusion potentially due to set misloading. Failure to properly load the tubing into the pump channel may result in the pump infusing at a rate higher or lower than programmed. Consistent with the instructions for use, customers should ensure that: 1) The door is fully open before loading the set. 2) The tubing is taut and loaded without slack in the pumping channel.
Z-2173-2025 · Root cause: Device Design · Recall details · FDA record ↗
- May 12, 2025Open, Classified
Baxter has identified a design issue which may cause the pump to detect the presence of a syringe flange when no syringe is loaded. When this issue occurs, the pumps 'user interface becomes stuck on the "Remove Syringe" screen when an infusion is complete, and the syringe is unloaded. A System Error 21502 (Flange Sensor Failure) may occur. Please note this issue only affects a subset of Novum IQ syringe pumps manufactured or repaired after July 4, 2023.
Z-1964-2025 · Root cause: Device Design · Recall details · FDA record ↗
- Mar 3, 2025Open, Classified
Baxter Healthcare Corporation is issuing an Urgent Medical Device Recall for the Novum IQ syringe pumps listed below due to an incorrectly installed gasket. A gasket failure could lead to potential fluid ingress due to cleaning, or as a result of an IV fluid spill.
Z-1423-2025 · Root cause: Process control · Recall details · FDA record ↗
Most reported Novum IQ problems
Device problems
- Filling Problem397
- Insufficient Flow or Under Infusion222
- Protective Measures Problem220
- False Alarm157
- Failure to Infuse136
- Failure to Sense78
- Excess Flow or Over-Infusion70
- No Display/Image69
Patient problems
- No Clinical Signs, Symptoms or Conditions1,399
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available60
- Low Blood Pressure/ Hypotension39
- High Blood Pressure/ Hypertension12
- Insufficient Information8
- Hemorrhage/Blood Loss/Bleeding7
- Irritability6
- Tachycardia6
Novum IQ models
3 models, most reported first. Each model has its own page with its reports, recalls and device details.
- Novum IQ 40700BAXUSPump, infusion2 recalls4 deaths1,192 reports
- Novum IQ 40800BAXUSPump, infusion4 recalls348 reports
- Novum IQ 40800BAXUSLPump, infusion, enteral1 recall0 reports
Recent Novum IQ adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionSep 25, 2026Connection Problem
It was reported that an unspecified quantity of Novum IQ Syringe Pumps had connection concerns when used with 35 mL non-Baxter ENFit syringes. Similar concerns were reported with another type of non-Baxter ENFit syringe. This occurred during an unspecified process step. There was no report of patient injury or medical intervention associated with this event. No additional information is available.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50897292 ↗MalfunctionSep 24, 2026Insufficient Flow or Under Infusion
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50891198 ↗MalfunctionSep 24, 2026Insufficient Flow or Under Infusion
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50890976 ↗InjurySep 22, 2026Filling Problem
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 50854186 ↗MalfunctionSep 22, 2026No Display/Image
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50849376 ↗MalfunctionSep 21, 2026Filling Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50849271 ↗MalfunctionSep 18, 2026Filling Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50824227 ↗MalfunctionSep 18, 2026Filling Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50821442 ↗MalfunctionSep 16, 2026Filling Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50792350 ↗MalfunctionSep 16, 2026No Display/Image
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50787220 ↗MalfunctionSep 8, 2026False Alarm; Excess Flow or Over-Infusion
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50678768 ↗MalfunctionSep 7, 2026Filling Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50658554 ↗MalfunctionSep 1, 2026Filling Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50546052 ↗MalfunctionAug 28, 2026Backflow
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50505987 ↗MalfunctionAug 26, 2026Excess Flow or Over-Infusion
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50459555 ↗
Other Baxter Healthcare Corporation products
- EXACTAMIX28 models · 6,739 reports · 13 recalls
- MiniCap3 models · 3,423 reports · 7 recalls
- CLEARLINK/CONTINU-FLO/DUO-VENT3 models · 873 reports · 3 recalls
- CLEARLINK19 models · 710 reports · 4 recalls
- CLEARLINK/CONTINU-FLO8 models · 416 reports · 4 recalls
- CLEARLINK/DUO-VENT5 models · 282 reports · 1 recall
- REPEATER6 models · 189 reports
- DUO-VENT5 models · 31 reports · 2 recalls
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page