Baxter Healthcare Corporation · 3 models in the FDA device registry

Data updated Oct 16, 2026 from official FDA records · Editorial policy

7 open recalls name at least one Novum IQ model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.

Adverse event reports
1,540
Deaths reported
4
Injuries reported
135
Recalls
7

We found 3 models of Novum IQ by Baxter Healthcare Corporation in the FDA's device registry (GUDID). Together they are named in 1,540 adverse event reports in the FDA's MAUDE database, received between Oct 5, 2023 and Sep 25, 2026 — classified as 4 deaths, 135 injuries, 1,401 malfunctions.

The most frequently reported specific device problem is “Filling Problem” (397 reports).

7 FDA recall records name at least one of these models by its device identifier, 7 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works

Reports received per month, all models

Nov 2023: 3 reportsDec 2023: 2 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 2 reportsMay 2024: 2 reportsJun 2024: 16 reportsJul 2024: 2 reportsAug 2024: 2 reportsSep 2024: 6 reportsOct 2024: 22 reportsNov 2024: 16 reportsDec 2024: 10 reportsJan 2025: 19 reportsFeb 2025: 10 reportsMar 2025: 352 reportsApr 2025: 262 reportsMay 2025: 141 reportsJun 2025: 62 reportsJul 2025: 77 reportsAug 2025: 55 reportsSep 2025: 29 reportsOct 2025: 30 reportsNov 2025: 96 reportsDec 2025: 33 reportsJan 2026: 64 reportsFeb 2026: 40 reportsMar 2026: 50 reportsApr 2026: 33 reportsMay 2026: 39 reportsJun 2026: 31 reportsJul 2026: 11 reportsAug 2026: 8 reportsSep 2026: 13 reportsOct 2026: 0 reports202420252026352
Last 36 months. The most recent month may be incomplete.

Novum IQ recalls

FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.

  1. Aug 11, 2026Open, Classified

    A software issue that may occur during a Volume/Time (VOT) multi-syringe infusion when a syringe reaches empty and is replaced while a Volume To Be Infused (VTBI) remains.

    Z-3066-2026 · Root cause: Software design · Recall details · FDA record ↗

  2. Aug 11, 2026Open, Classified

    A software issue that may occur during a Volume/Time (VOT) multi-syringe infusion when a syringe reaches empty and is replaced while a Volume To Be Infused (VTBI) remains.

    Z-3065-2026 · Root cause: Software design · Recall details · FDA record ↗

  3. Aug 4, 2025Open, Classified

    Baxter Healthcare Corporation is issuing an Urgent Medical Device Correction for the Novum IQ Large Volume Pump (LVP) and Novum IQ Syringe Pump (SP) due to software anomalies that may result in a blank Run screen (LVP and SP) and/or false motor movement system error (SP only).

    Z-2333-2025 · Root cause: Software design (manufacturing process) · Recall details · FDA record ↗

  4. Aug 4, 2025Open, Classified

    Baxter Healthcare Corporation is issuing an Urgent Medical Device Correction for the Novum IQ Large Volume Pump (LVP) and Novum IQ Syringe Pump (SP) due to software anomalies that may result in a blank Run screen (LVP and SP) and/or false motor movement system error (SP only).

    Z-2332-2025 · Root cause: Software design (manufacturing process) · Recall details · FDA record ↗

  5. Jul 14, 2025Open, Classified

    Baxter is issuing an Urgent Medical Device Correction for the Novum IQ large volume pump (LVP) due to the potential for underinfusion when transitioning from a flow rate to a higher flow rate that is more than double. (e.g., rate change or bolus). The level of underinfusion is variable based on the current infusion rate, the duration the pump has been running at this flow rate, and the magnitude of the rate change. The longer the duration the pump has been running at the current infusion rate and the larger the magnitude of the rate change, the larger the underinfusion that would be experienced. Additionally, Baxter has identified an increase in customer reports of over and underinfusion potentially due to set misloading. Failure to properly load the tubing into the pump channel may result in the pump infusing at a rate higher or lower than programmed. Consistent with the instructions for use, customers should ensure that: 1) The door is fully open before loading the set. 2) The tubing is taut and loaded without slack in the pumping channel.

    Z-2173-2025 · Root cause: Device Design · Recall details · FDA record ↗

  6. May 12, 2025Open, Classified

    Baxter has identified a design issue which may cause the pump to detect the presence of a syringe flange when no syringe is loaded. When this issue occurs, the pumps 'user interface becomes stuck on the "Remove Syringe" screen when an infusion is complete, and the syringe is unloaded. A System Error 21502 (Flange Sensor Failure) may occur. Please note this issue only affects a subset of Novum IQ syringe pumps manufactured or repaired after July 4, 2023.

    Z-1964-2025 · Root cause: Device Design · Recall details · FDA record ↗

  7. Mar 3, 2025Open, Classified

    Baxter Healthcare Corporation is issuing an Urgent Medical Device Recall for the Novum IQ syringe pumps listed below due to an incorrectly installed gasket. A gasket failure could lead to potential fluid ingress due to cleaning, or as a result of an IV fluid spill.

    Z-1423-2025 · Root cause: Process control · Recall details · FDA record ↗

Most reported Novum IQ problems

Device problems

  • Filling Problem397
  • Insufficient Flow or Under Infusion222
  • Protective Measures Problem220
  • False Alarm157
  • Failure to Infuse136
  • Failure to Sense78
  • Excess Flow or Over-Infusion70
  • No Display/Image69

Patient problems

  • No Clinical Signs, Symptoms or Conditions1,399
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available60
  • Low Blood Pressure/ Hypotension39
  • High Blood Pressure/ Hypertension12
  • Insufficient Information8
  • Hemorrhage/Blood Loss/Bleeding7
  • Irritability6
  • Tachycardia6

Novum IQ models

3 models, most reported first. Each model has its own page with its reports, recalls and device details.

Recent Novum IQ adverse event reports

The 15 most recent reports across all models, in the reporter's own words as published by the FDA.