Guardian 4 SensorRecalls & reported problems across all models
Medtronic Minimed, Inc. · 2 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
1 open recall names at least one Guardian 4 Sensor model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 0
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls
- 1
We found 2 models of Guardian 4 Sensor by Medtronic Minimed, Inc. in the FDA's device registry (GUDID). None of them is named in an adverse event report in our data.
1 FDA recall record name at least one of these models by its device identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Guardian 4 Sensor recalls
FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.
- Nov 15, 2023Open, Classified
Some sensors may have a glucose oxidase (GOX) layer thickness outside of specification (5.5 to 9.2 m). A non-conforming GOX layer thickness could impact sensor function (sensor glucose value) or loss of sensor function due to the sensor layer being too thin. The potential impact resulting from this issue ranges from user inconvenience to over/under delivery of insulin, possibly resulting in hyperglycemia or hypoglycemia, if the sensor glucose values are affected. The issue was identified by the manufacturing team during the execution of Filmetrics Measurement for a Guardian Sensor lot.
Z-1005-2024 · Root cause: Process change control · names 2 of these models · Recall details · FDA record ↗
Guardian 4 Sensor models
2 models, most reported first. Each model has its own page with its reports, recalls and device details.
- Guardian™ 4 Sensor MMT-7040ASensor, Glucose, Invasive, Component of automated insulin delivery system1 recall0 reports
- Guardian™ 4 Sensor MMT-7040MASensor, Glucose, Invasive, Component of automated insulin delivery system1 recall0 reports
Other Medtronic Minimed, Inc. products
- MiniMed 670G23 models · 141,169 reports · 4 recalls
- MiniMed 630G23 models · 65,972 reports · 6 recalls
- Paradigm REAL-Time Revel180 models · 49,838 reports · 2 recalls
- MiniMed 530G71 models · 48,745 reports · 1 recall
- MiniMed670G2 models · 28,871 reports · 3 recalls
- MiniMed630G2 models · 6,656 reports · 5 recalls
- MiniMed Reservoir6 models · 4,545 reports
- PARADIGM REAL-time95 models · 2,862 reports · 1 recall
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.