Merge CardioRecalls & reported problems across all models
Merge Healthcare Solutions Inc. · 6 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
4 open recalls name at least one Merge Cardio model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 34
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls
- 5
We found 6 models of Merge Cardio by Merge Healthcare Solutions Inc. in the FDA's device registry (GUDID). Together they are named in 34 adverse event reports in the FDA's MAUDE database, received between Aug 12, 2018 and Mar 20, 2025 — classified as 1 death, 33 malfunctions.
The most frequently reported specific device problem is “Application Program Problem: Parameter Calculation Error” (12 reports).
5 FDA recall records name at least one of these models by its device identifier, 4 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Merge Cardio recalls
FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.
- Feb 19, 2025Open, Classified
When following a specific less typical workflow in which the user remeasures using the ultrasound device or manually edits primitive or derived measurement values directly in Clinical Reporting, derived measurements may be inconsistent with the associated primitive measurements in the final patient report.
Z-1402-2025 · Root cause: Software design · names 3 of these models · Recall details · FDA record ↗
- Feb 19, 2025Open, Classified
When following a specific less typical workflow in which the user remeasures using the ultrasound device or manually edits primitive or derived measurement values directly in Clinical Reporting, derived measurements may be inconsistent with the associated primitive measurements in the final patient report.
Z-1401-2025 · Root cause: Software design · Recall details · FDA record ↗
- Feb 19, 2025Open, Classified
When following a specific less typical workflow in which the user remeasures using the ultrasound device or manually edits primitive or derived measurement values directly in Clinical Reporting, derived measurements may be inconsistent with the associated primitive measurements in the final patient report.
Z-1400-2025 · Root cause: Software design · Recall details · FDA record ↗
- Feb 19, 2025Open, Classified
When following a specific less typical workflow in which the user remeasures using the ultrasound device or manually edits primitive or derived measurement values directly in Clinical Reporting, derived measurements may be inconsistent with the associated primitive measurements in the final patient report.
Z-1399-2025 · Root cause: Software design · Recall details · FDA record ↗
- May 8, 2020Terminated
An error in the calculation of the Michigan Reference Ranges can generate an inaccurate Z-Score calculation. The error may reduce the sensitivity of the Z-Score in detecting an abnormality resulting in a false negative.
Z-2403-2020 · Root cause: Software Design Change · names 2 of these models · Recall details · FDA record ↗
Most reported Merge Cardio problems
Device problems
- Application Program Problem: Parameter Calculation Error12
- Data Problem11
- Application Program Problem6
- Computer Software Problem6
- Loss of Data2
- Patient Data Problem2
- Adverse Event Without Identified Device or Use Problem1
- No Apparent Adverse Event1
Patient problems
- No Clinical Signs, Symptoms or Conditions22
- No Known Impact Or Consequence To Patient13
- Insufficient Information1
- Unspecified Heart Problem1
Merge Cardio models
6 models, most reported first. Each model has its own page with its reports, recalls and device details.
- Merge Cardio 10.3System, Image Processing, Radiological2 recalls13 reports
- Merge Cardio 11.0System, Image Processing, Radiological2 recalls8 reports
- Merge Cardio 12.1System, Image Processing, Radiological1 recall1 death8 reports
- Merge Cardio 12.0.1System, Image Processing, Radiological1 recall4 reports
- Merge Cardio 12.2System, Image Processing, Radiological1 recall1 report
- Merge Cardio 12.4System, Image Processing, Radiological1 recall0 reports
Recent Merge Cardio adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
DeathMar 20, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
MERGE CARDIO IS A SYSTEM INTENDED TO BE USED TO ACQUIRE, STORE, PRINT, TRANSFER, AND ARCHIVE CLINICAL INFORMATION FROM MERGE HEALTHCARE AND OTHER VENDORS SYSTEMS INCLUDING IMAGES, HEMODYNAMIC STUDIES AND REPORTS, MEASUREMENTS (VIA IMPORT FROM DICOM STRUCTURED REPORTING, TEXT FILES OR OPTICAL CHARACTER RECOGNITION OF MEASUREMENTS CAPTURED ON IMAGES) AND CARDIOLOGY SIGNAL (WAVEFORM) DATA. MERGE CARDIO IS INTENDED TO ALLOW USERS TO REVIEW DIAGNOSTIC AND NON-DIAGNOSTIC QUALITY IMAGES, ANNOTATE STUDIES, PERFORM DIGITAL SUBTRACTION ON IMAGES, TO PERFORM QUANTITATIVE MEASUREMENTS ON IMAGES (INCLUDING BUT NOT LIMITED TO QUANTITATIVE CORONARY ANALYSIS, LEFT VENTRICULAR ANALYSIS, TIME, AREA, LENGTH, VELOCITY, ANGLE, VOLUME, AND VELOCITY-TIME INTEGRALS), TO GENERATE PHYSICIAN GENERATED CLINICAL REPORTS (VIA STRUCTURE REPORTING AND TEMPLATE BASED TOOLS), AND TO STORE THIS INFORMATION IN A DATABASE. ON 02/19/2025, A CUSTOMER CONTACTED MERGE HEALTHCARE FOR ASSISTANCE WITH MERGE CARDIO'S STUDY LIST FILTERS. MERGE TECHNICAL SUPPORT REMOTELY CONNECTED TO THE CUSTOMER'S SYSTEM TO ASSIST WITH FILTER QUESTIONS. THE CUSTOMER WAS ATTEMPTING TO LOCATE A ECHOCARDIOGRAM PATIENT STUDY PERFORMED ON (B)(6) 20
Patient problems: Insufficient Information; Unspecified Heart Problem
MAUDE report 21656629 ↗MalfunctionOct 28, 2023No Apparent Adverse Event; No Apparent Adverse Event
MERGE CARDIO IS A SYSTEM INTENDED TO BE USED TO ACQUIRE, STORE, PRINT, TRANSFER, AND ARCHIVE CLINICAL INFORMATION FROM MERGE HEALTHCARE AND OTHER VENDORS SYSTEMS INCLUDING IMAGES, HEMODYNAMIC STUDIES AND REPORTS, MEASUREMENTS (VIA IMPORT FROM DICOM STRUCTURED REPORTING, TEXT FILES OR OPTICAL CHARACTER RECOGNITION OF MEASUREMENTS CAPTURED ON IMAGES) AND CARDIOLOGY SIGNAL (WAVEFORM) DATA. MERGE CARDIO IS INTENDED TO ALLOW USERS TO REVIEW DIAGNOSTIC AND NON-DIAGNOSTIC QUALITY IMAGES, ANNOTATE STUDIES, PERFORM DIGITAL SUBTRACTION ON IMAGES, TO PERFORM QUANTITATIVE MEASUREMENTS ON IMAGES (INCLUDING BUT NOT LIMITED TO QUANTITATIVE CORONARY ANALYSIS, LEFT VENTRICULAR ANALYSIS, TIME, AREA, LENGTH, VELOCITY, ANGLE, VOLUME, AND VELOCITY-TIME INTEGRALS), TO GENERATE PHYSICIAN GENERATED CLINICAL REPORTS (VIA STRUCTURE REPORTING AND TEMPLATE BASED TOOLS), AND TO STORE THIS INFORMATION IN A DATABASE. ON 10/20/2023, MERGE HEALTHCARE WAS NOTIFIED VIA EMAIL THAT A MEDICAL DEVICE REPORT (B)(4) CONCERNING OUR PRODUCT WAS SUBMITTED TO THE FDA VIA THE MEDWATCH PROGRAM. MERGE HEALTHCARE HAS BEEN IN CONTACT WITH THE CUSTOMER. A SERVICE CASE, (B)(4), WAS OPENED ON (B)(6) 2023. THE CUSTOMER ALLEGED THAT EX
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18026719 ↗MalfunctionJun 23, 2023Computer Software Problem; Computer Software Problem
MERGE CARDIO IS A SYSTEM INTENDED TO BE USED TO ACQUIRE, STORE, PRINT, TRANSFER, AND ARCHIVE CLINICAL INFORMATION FROM MERGE HEALTHCARE AND OTHER VENDORS SYSTEMS INCLUDING IMAGES, HEMODYNAMIC STUDIES AND REPORTS, MEASUREMENTS (VIA IMPORT FROM DICOM STRUCTURED REPORTING, TEXT FILES OR OPTICAL CHARACTER RECOGNITION OF MEASUREMENTS CAPTURED ON IMAGES) AND CARDIOLOGY SIGNAL (WAVEFORM) DATA. MERGE CARDIO IS INTENDED TO ALLOW USERS TO REVIEW DIAGNOSTIC AND NON-DIAGNOSTIC QUALITY IMAGES, ANNOTATE STUDIES, PERFORM DIGITAL SUBTRACTION ON IMAGES, TO PERFORM QUANTITATIVE MEASUREMENTS ON IMAGES (INCLUDING BUT NOT LIMITED TO QUANTITATIVE CORONARY ANALYSIS, LEFT VENTRICULAR ANALYSIS, TIME, AREA, LENGTH, VELOCITY, ANGLE, VOLUME, AND VELOCITY-TIME INTEGRALS), TO GENERATE PHYSICIAN GENERATED CLINICAL REPORTS (VIA STRUCTURE REPORTING AND TEMPLATE BASED TOOLS), AND TO STORE THIS INFORMATION IN A DATABASE. ON (B)(6) 2023, A CUSTOMER CONTACTED MERGE HEALTHCARE ALLEGING THAT SOME MITRAL VALVE MEASUREMENTS, IMPORTED INTO MERGE CARDIO FROM A 3RD PARTY TOOL, WERE SHOWING A DIFFERENT UNIT OF MEASUREMENT THAN THE MEASUREMENT UNITS IN MERGE CARDIO. WORK IS ONGOING BETWEEN THE CUSTOMER AND MERGE HEALTHCARE. A
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17195030 ↗MalfunctionNov 29, 2022Computer Software Problem; Use of Device Problem; Application Program Problem; Computer Software Problem; Use of Device Problem; Application Program Problem
MERGE CARDIO IS A SYSTEM INTENDED TO BE USED TO ACQUIRE, STORE, PRINT, TRANSFER, AND ARCHIVE CLINICAL INFORMATION FROM MERGE HEALTHCARE AND OTHER VENDORS SYSTEMS INCLUDING IMAGES, HEMODYNAMIC STUDIES AND REPORTS, MEASUREMENTS (VIA IMPORT FROM DICOM STRUCTURED REPORTING, TEXT FILES OR OPTICAL CHARACTER RECOGNITION OF MEASUREMENTS CAPTURED ON IMAGES) AND CARDIOLOGY SIGNAL (WAVEFORM) DATA. MERGE CARDIO IS INTENDED TO ALLOW USERS TO REVIEW DIAGNOSTIC AND NON-DIAGNOSTIC QUALITY IMAGES, ANNOTATE STUDIES, PERFORM DIGITAL SUBTRACTION ON IMAGES, TO PERFORM QUANTITATIVE MEASUREMENTS ON IMAGES (INCLUDING BUT NOT LIMITED TO QUANTITATIVE CORONARY ANALYSIS, LEFT VENTRICULAR ANALYSIS, TIME, AREA, LENGTH, VELOCITY, ANGLE, VOLUME, AND VELOCITY-TIME INTEGRALS), TO GENERATE PHYSICIAN GENERATED CLINICAL REPORTS (VIA STRUCTURE REPORTING AND TEMPLATE BASED TOOLS), AND TO STORE THIS INFORMATION IN A DATABASE. ON 11/01//2022, A PACS APPLICATION ADMINISTRATOR CONTACTED MERGE HEALTHCARE ALLEGING THAT SOMETIMES A DIFFERENT PATIENT'S INFO APPEARS UNEXPECTEDLY WHEN UTILIZING THREE DIFFERENT SYSTEMS (EPIC, MERGE CARDIO AND TOMTEC) AT THE SAME TIME. ACCORDING TO THE PACS ADMINISTRATOR, THIS CAN HAPPEN WHEN A USE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15881783 ↗MalfunctionJul 28, 2022Computer Software Problem; Application Program Problem; Computer Software Problem; Application Program Problem
MERGE CARDIO IS A SYSTEM INTENDED TO BE USED TO ACQUIRE, STORE, PRINT, TRANSFER, AND ARCHIVE CLINICAL INFORMATION FROM MERGE HEALTHCARE AND OTHER VENDORS SYSTEMS INCLUDING IMAGES, HEMODYNAMIC STUDIES AND REPORTS, MEASUREMENTS (VIA IMPORT FROM DICOM STRUCTURED REPORTING, TEXT FILES OR OPTICAL CHARACTER RECOGNITION OF MEASUREMENTS CAPTURED ON IMAGES) AND CARDIOLOGY SIGNAL (WAVEFORM) DATA. MERGE CARDIO IS INTENDED TO ALLOW USERS TO REVIEW DIAGNOSTIC AND NON-DIAGNOSTIC QUALITY IMAGES, ANNOTATE STUDIES, PERFORM DIGITAL SUBTRACTION ON IMAGES, TO PERFORM QUANTITATIVE MEASUREMENTS ON IMAGES (INCLUDING BUT NOT LIMITED TO QUANTITATIVE CORONARY ANALYSIS, LEFT VENTRICULAR ANALYSIS, TIME, AREA, LENGTH, VELOCITY, ANGLE, VOLUME, AND VELOCITY-TIME INTEGRALS), TO GENERATE PHYSICIAN GENERATED CLINICAL REPORTS (VIA STRUCTURE REPORTING AND TEMPLATE BASED TOOLS), AND TO STORE THIS INFORMATION IN A DATABASE. ON 06/30/2022 A TECHNOLOGIST CONTACTED MERGE HELATHCARE ALLEGING THAT THE SIMPSON'S BIPLANE MEASUREMENT IS INCORRECT ON MERGE CARDIO VERSION 12.1.1. WORK IS ONGOING BETWEEN THE CUSTOMER AND MERGE HEALTHCARE. A SUPPLEMENTAL REPORT WILL BE FILED WHEN FURTHER INFORMATION BECOMES AVAILABLE. THIS HAS THE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15123249 ↗MalfunctionJul 20, 2022Computer Software Problem; Application Program Problem; Computer Software Problem; Application Program Problem
MERGE CARDIO IS A SYSTEM INTENDED TO BE USED TO ACQUIRE, STORE, PRINT, TRANSFER, AND ARCHIVE CLINICAL INFORMATION FROM MERGE HEALTHCARE AND OTHER VENDORS SYSTEMS INCLUDING IMAGES, HEMODYNAMIC STUDIES AND REPORTS, MEASUREMENTS (VIA IMPORT FROM DICOM STRUCTURED REPORTING, TEXT FILES OR OPTICAL CHARACTER RECOGNITION OF MEASUREMENTS CAPTURED ON IMAGES) AND CARDIOLOGY SIGNAL (WAVEFORM) DATA. MERGE CARDIO IS INTENDED TO ALLOW USERS TO REVIEW DIAGNOSTIC AND NON-DIAGNOSTIC QUALITY IMAGES, ANNOTATE STUDIES, PERFORM DIGITAL SUBTRACTION ON IMAGES, TO PERFORM QUANTITATIVE MEASUREMENTS ON IMAGES (INCLUDING BUT NOT LIMITED TO QUANTITATIVE CORONARY ANALYSIS, LEFT VENTRICULAR ANALYSIS, TIME, AREA, LENGTH, VELOCITY, ANGLE, VOLUME, AND VELOCITY-TIME INTEGRALS), TO GENERATE PHYSICIAN GENERATED CLINICAL REPORTS (VIA STRUCTURE REPORTING AND TEMPLATE BASED TOOLS), AND TO STORE THIS INFORMATION IN A DATABASE. ON (B)(6) 2022, AN INTERNAL MERGE CARDIO TRAINER RECEIVED FEEDBACK FROM A USER WHO NOTICED DIFFERENCES BETWEEN THE MEASUREMENT TOOL NOMENCLATURE AND THE PATIENT REPORT. THE ISSUE IS BEING INVESTIGATED AND WORK IS ONGOING BETWEEN THE CUSTOMER AND MERGE HEALTHCARE. A SUPPLEMENTAL REPORT WILL BE FILED
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15065231 ↗MalfunctionJun 8, 2022Computer Software Problem; Application Program Problem; Computer Software Problem; Application Program Problem
MERGE CARDIO IS A SYSTEM INTENDED TO BE USED TO ACQUIRE, STORE, PRINT, TRANSFER, AND ARCHIVE CLINICAL INFORMATION FROM MERGE HEALTHCARE AND OTHER VENDORS SYSTEMS INCLUDING IMAGES, HEMODYNAMIC STUDIES AND REPORTS, MEASUREMENTS (VIA IMPORT FROM DICOM STRUCTURED REPORTING, TEXT FILES OR OPTICAL CHARACTER RECOGNITION OF MEASUREMENTS CAPTURED ON IMAGES) AND CARDIOLOGY SIGNAL (WAVEFORM) DATA. MERGE CARDIO IS INTENDED TO ALLOW USERS TO REVIEW DIAGNOSTIC AND NON-DIAGNOSTIC QUALITY IMAGES, ANNOTATE STUDIES, PERFORM DIGITAL SUBTRACTION ON IMAGES, TO PERFORM QUANTITATIVE MEASUREMENTS ON IMAGES (INCLUDING BUT NOT LIMITED TO QUANTITATIVE CORONARY ANALYSIS, LEFT VENTRICULAR ANALYSIS, TIME, AREA, LENGTH, VELOCITY, ANGLE, VOLUME, AND VELOCITY-TIME INTEGRALS), TO GENERATE PHYSICIAN GENERATED CLINICAL REPORTS (VIA STRUCTURE REPORTING AND TEMPLATE BASED TOOLS), AND TO STORE THIS INFORMATION IN A DATABASE. ON 05/12/2022, AN INTERNAL CLINICAL CONTENT REPORTING ENGINEER FOUND AN INCORRECTLY MAPPED MEASUREMENT DURING A TRAINING SESSION FOR MERGE CARDIO VERSION 12.1.1. THE CUSTOMER REQUESTED LEFT ATRIA AND VENTRICLE VOLUME MEASUREMENTS TO BE CONFIGURED ON MERGE CARDIO REPORTS. THE CUSTOMER ALLEGED THAT TH
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14640351 ↗MalfunctionJun 6, 2022Application Program Problem; Application Program Problem
MERGE CARDIO IS A SYSTEM INTENDED TO BE USED TO ACQUIRE, STORE, PRINT, TRANSFER, AND ARCHIVE CLINICAL INFORMATION FROM MERGE HEALTHCARE AND OTHER VENDORS SYSTEMS INCLUDING IMAGES, HEMODYNAMIC STUDIES AND REPORTS, MEASUREMENTS (VIA IMPORT FROM DICOM STRUCTURED REPORTING, TEXT FILES OR OPTICAL CHARACTER RECOGNITION OF MEASUREMENTS CAPTURED ON IMAGES) AND CARDIOLOGY SIGNAL (WAVEFORM) DATA. MERGE CARDIO IS INTENDED TO ALLOW USERS TO REVIEW DIAGNOSTIC AND NON-DIAGNOSTIC QUALITY IMAGES, ANNOTATE STUDIES, PERFORM DIGITAL SUBTRACTION ON IMAGES, TO PERFORM QUANTITATIVE MEASUREMENTS ON IMAGES (INCLUDING BUT NOT LIMITED TO QUANTITATIVE CORONARY ANALYSIS, LEFT VENTRICULAR ANALYSIS, TIME, AREA, LENGTH, VELOCITY, ANGLE, VOLUME, AND VELOCITY-TIME INTEGRALS), TO GENERATE PHYSICIAN GENERATED CLINICAL REPORTS (VIA STRUCTURE REPORTING AND TEMPLATE BASED TOOLS), AND TO STORE THIS INFORMATION IN A DATABASE. ON 05/09/2022, AN INTERNAL CLINICAL CONTENT REPORTING ENGINEER FOUND AN INCORRECTLY MAPPED MEASUREMENT DURING A TRAINING SESSION FOR MERGE CARDIO VERSION 12.1.1. THE CUSTOMER REQUESTED LEFT ATRIA AND VENTRICLE VOLUME MEASUREMENTS TO BE CONFIGURED ON MERGE CARDIO REPORTS. THE CUSTOMER ALLEGED THAT TH
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14606048 ↗MalfunctionMar 23, 2022Application Program Problem; Application Program Problem
MERGE CARDIO IS A SYSTEM INTENDED TO BE USED TO ACQUIRE, STORE, PRINT, TRANSFER, AND ARCHIVE CLINICAL INFORMATION FROM MERGE HEALTHCARE AND OTHER VENDORS SYSTEMS INCLUDING IMAGES, HEMODYNAMIC STUDIES AND REPORTS, MEASUREMENTS (VIA IMPORT FROM DICOM STRUCTURED REPORTING, TEXT FILES OR OPTICAL CHARACTER RECOGNITION OF MEASUREMENTS CAPTURED ON IMAGES) AND CARDIOLOGY SIGNAL (WAVEFORM) DATA. MERGE CARDIO IS INTENDED TO ALLOW USERS TO REVIEW DIAGNOSTIC AND NON-DIAGNOSTIC QUALITY IMAGES, ANNOTATE STUDIES, PERFORM DIGITAL SUBTRACTION ON IMAGES, TO PERFORM QUANTITATIVE MEASUREMENTS ON IMAGES (INCLUDING BUT NOT LIMITED TO QUANTITATIVE CORONARY ANALYSIS, LEFT VENTRICULAR ANALYSIS, TIME, AREA, LENGTH, VELOCITY, ANGLE, VOLUME, AND VELOCITY TIME INTEGRALS), TO GENERATE PHYSICIAN GENERATED CLINICAL REPORTS (VIA STRUCTURE REPORTING AND TEMPLATE BASED TOOLS), AND TO STORE THIS INFORMATION IN A DATABASE. ON 02/24/2022, AN INTERNAL CLINICAL REPORTING SPECIALIST FOUND AN INCORRECTLY MAPPED MEASUREMENT DURING AN UPGRADE TO MERGE CARDIO VERSION 12.1.1. THE CUSTOMER REQUESTED HEPATIC VEIN MEASUREMENTS TO BE CONFIGURED ON MERGE CARDIO REPORTS. IT WAS FOUND THAT THE HEPATIC VEIN DIASTOLIC PEAK VELOCITY DIS
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13864771 ↗MalfunctionDec 29, 2021Application Program Problem: Parameter Calculation Error; Application Program Problem: Parameter Calculation Error
MERGE CARDIO IS A SYSTEM INTENDED TO BE USED TO ACQUIRE, STORE, PRINT, TRANSFER, AND ARCHIVE CLINICAL INFORMATION FROM MERGE HEALTHCARE AND OTHER VENDORS SYSTEMS INCLUDING IMAGES, HEMODYNAMIC STUDIES AND REPORTS, MEASUREMENTS (VIA IMPORT FROM DICOM STRUCTURED REPORTING, TEXT FILES OR OPTICAL CHARACTER RECOGNITION OF MEASUREMENTS CAPTURED ON IMAGES) AND CARDIOLOGY SIGNAL (WAVEFORM) DATA. MERGE CARDIO IS INTENDED TO ALLOW USERS TO REVIEW DIAGNOSTIC AND NON-DIAGNOSTIC QUALITY IMAGES, ANNOTATE STUDIES, PERFORM DIGITAL SUBTRACTION ON IMAGES, TO PERFORM QUANTITATIVE MEASUREMENTS ON IMAGES (INCLUDING BUT NOT LIMITED TO QUANTITATIVE CORONARY ANALYSIS, LEFT VENTRICULAR ANALYSIS, TIME, AREA, LENGTH, VELOCITY, ANGLE, VOLUME, AND VELOCITY-TIME INTEGRALS), TO GENERATE PHYSICIAN GENERATED CLINICAL REPORTS (VIA STRUCTURE REPORTING AND TEMPLATE BASED TOOLS), AND TO STORE THIS INFORMATION IN A DATABASE. ON 12/7//2021, A CUSTOMER CONTACTED MERGE HEALTHCARE TO REPORT THAT THE RIGHT VENTRICULAR SYSTOLIC (RV S) MEASUREMENT WAS MAPPED INCORRECTLY. MERGE HEALTHCARE TECHNICAL SUPPORT WAS ABLE TO WORK WITH THE CUSTOMER TO REMAP THE MEASUREMENT AND CONFIRMED THAT IT WAS DISPLAYING CORRECTLY. NO FURTHER ACTI
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13114872 ↗MalfunctionOct 21, 2021Application Program Problem: Parameter Calculation Error; Application Program Problem: Parameter Calculation Error
MERGE CARDIO IS A SYSTEM INTENDED TO BE USED TO ACQUIRE, STORE, PRINT, TRANSFER, AND ARCHIVE CLINICAL INFORMATION FROM MERGE HEALTHCARE AND OTHER VENDORS SYSTEMS INCLUDING IMAGES, HEMODYNAMIC STUDIES AND REPORTS, MEASUREMENTS (VIA IMPORT FROM DICOM STRUCTURED REPORTING, TEXT FILES OR OPTICAL CHARACTER RECOGNITION OF MEASUREMENTS CAPTURED ON IMAGES) AND CARDIOLOGY SIGNAL (WAVEFORM) DATA. MERGE CARDIO IS INTENDED TO ALLOW USERS TO REVIEW DIAGNOSTIC AND NON-DIAGNOSTIC QUALITY IMAGES, ANNOTATE STUDIES, PERFORM DIGITAL SUBTRACTION ON IMAGES, TO PERFORM QUANTITATIVE MEASUREMENTS ON IMAGES (INCLUDING BUT NOT LIMITED TO QUANTITATIVE CORONARY ANALYSIS, LEFT VENTRICULAR ANALYSIS, TIME, AREA, LENGTH, VELOCITY, ANGLE, VOLUME, AND VELOCITY-TIME INTEGRALS), TO GENERATE PHYSICIAN GENERATED CLINICAL REPORTS (VIA STRUCTURE REPORTING AND TEMPLATE BASED TOOLS), AND TO STORE THIS INFORMATION IN A DATABASE. ON (B)(6) 2021, A CUSTOMER CONTACTED MERGE HEALTHCARE TO REPORT THAT THE BULLET END DIASTOLIC AREA MEASUREMENT WAS MAPPED INCORRECTLY. MERGE HEALTHCARE TECHNICAL SUPPORT WAS ABLE TO WORK WITH THE CUSTOMER TO REMAP THE MEASUREMENT AND CONFIRMED THAT IT WAS DISPLAYING CORRECTLY. NO FURTHER ACTION IS N
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12675598 ↗MalfunctionMay 5, 2021Application Program Problem: Parameter Calculation Error; Application Program Problem: Parameter Calculation Error
MERGE CARDIO IS A SYSTEM INTENDED TO BE USED TO ACQUIRE, STORE, PRINT, TRANSFER, AND ARCHIVE CLINICAL INFORMATION FROM MERGE HEALTHCARE AND OTHER VENDORS SYSTEMS INCLUDING IMAGES, HEMODYNAMIC STUDIES AND REPORTS, MEASUREMENTS (VIA IMPORT FROM DICOM STRUCTURED REPORTING, TEXT FILES OR OPTICAL CHARACTER RECOGNITION OF MEASUREMENTS CAPTURED ON IMAGES) AND CARDIOLOGY SIGNAL (WAVEFORM) DATA. MERGE CARDIO IS INTENDED TO ALLOW USERS TO REVIEW DIAGNOSTIC AND NON-DIAGNOSTIC QUALITY IMAGES, ANNOTATE STUDIES, PERFORM DIGITAL SUBTRACTION ON IMAGES, TO PERFORM QUANTITATIVE MEASUREMENTS ON IMAGES (INCLUDING BUT NOT LIMITED TO QUANTITATIVE CORONARY ANALYSIS, LEFT VENTRICULAR ANALYSIS, TIME, AREA, LENGTH, VELOCITY, ANGLE, VOLUME, AND VELOCITY-TIME INTEGRALS), TO GENERATE PHYSICIAN GENERATED CLINICAL REPORTS (VIA STRUCTURE REPORTING AND TEMPLATE BASED TOOLS), AND TO STORE THIS INFORMATION IN A DATABASE. ON (B)(6) 2021, A CUSTOMER CONTACTED MERGE HEALTHCARE TO REPORT THAT WHEN USING THE MEASUREMENT TOOL TO MEASURE RIGHT VENTRICLE TAPE, IN M-MODE THAT THE DECIMAL PLACE IS SHIFTED CAUSING THE MEASUREMENT TO LOOK INCORRECT IN THE REPORT AND WORKSTATION. WORK BETWEEN MERGE HEALTHCARE AND THE CUSTOMER IS
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11780292 ↗MalfunctionApr 6, 2021Application Program Problem: Parameter Calculation Error; Application Program Problem: Parameter Calculation Error
MERGE CARDIO IS A SYSTEM INTENDED TO BE USED TO ACQUIRE, STORE, PRINT, TRANSFER, AND ARCHIVE CLINICAL INFORMATION FROM MERGE HEALTHCARE AND OTHER VENDORS SYSTEMS INCLUDING IMAGES, HEMODYNAMIC STUDIES AND REPORTS, MEASUREMENTS (VIA IMPORT FROM DICOM STRUCTURED REPORTING, TEXT FILES OR OPTICAL CHARACTER RECOGNITION OF MEASUREMENTS CAPTURED ON IMAGES) AND CARDIOLOGY SIGNAL (WAVEFORM) DATA. MERGE CARDIO IS INTENDED TO ALLOW USERS TO REVIEW DIAGNOSTIC AND NON-DIAGNOSTIC QUALITY IMAGES, ANNOTATE STUDIES, PERFORM DIGITAL SUBTRACTION ON IMAGES, TO PERFORM QUANTITATIVE MEASUREMENTS ON IMAGES (INCLUDING BUT NOT LIMITED TO QUANTITATIVE CORONARY ANALYSIS, LEFT VENTRICULAR ANALYSIS, TIME, AREA, LENGTH, VELOCITY, ANGLE, VOLUME, AND VELOCITY-TIME INTEGRALS), TO GENERATE PHYSICIAN GENERATED CLINICAL REPORTS (VIA STRUCTURE REPORTING AND TEMPLATE BASED TOOLS), AND TO STORE THIS INFORMATION IN A DATABASE. ON (B)(6) 2021, A CUSTOMER CONTACTED MERGE HEALTHCARE TO REPORT THAT PREND VMAX WAS MAPPED TO PR PEAK VELOCITY AND SHOULD BE MAPPED TO PR PEAK IN END DIASTOLE AND THAT PREND PG WAS MAPPED TO PR PEAK GRADIENT AND SHOULD BE MAPPED TO PR GRADIENT IN END DIASTOLE. WORK BETWEEN MERGE HEALTHCARE AND THE C
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11624283 ↗MalfunctionFeb 2, 2021Application Program Problem: Parameter Calculation Error; Application Program Problem: Parameter Calculation Error
MERGE CARDIO IS A SYSTEM INTENDED TO BE USED TO ACQUIRE, STORE, PRINT, TRANSFER, AND ARCHIVE CLINICAL INFORMATION FROM MERGE HEALTHCARE AND OTHER VENDORS SYSTEMS INCLUDING IMAGES, HEMODYNAMIC STUDIES AND REPORTS, MEASUREMENTS (VIA IMPORT FROM DICOM STRUCTURED REPORTING, TEXT FILES OR OPTICAL CHARACTER RECOGNITION OF MEASUREMENTS CAPTURED ON IMAGES) AND CARDIOLOGY SIGNAL (WAVEFORM) DATA. MERGE CARDIO IS INTENDED TO ALLOW USERS TO REVIEW DIAGNOSTIC AND NON-DIAGNOSTIC QUALITY IMAGES, ANNOTATE STUDIES, PERFORM DIGITAL SUBTRACTION ON IMAGES, TO PERFORM QUANTITATIVE MEASUREMENTS ON IMAGES (INCLUDING BUT NOT LIMITED TO QUANTITATIVE CORONARY ANALYSIS, LEFT VENTRICULAR ANALYSIS, TIME, AREA, LENGTH, VELOCITY, ANGLE, VOLUME, AND VELOCITY-TIME INTEGRALS), TO GENERATE PHYSICIAN GENERATED CLINICAL REPORTS (VIA STRUCTURE REPORTING AND TEMPLATE BASED TOOLS), AND TO STORE THIS INFORMATION IN A DATABASE. ON 1/15/2021, A CUSTOMER CONTACTED MERGE HEALTHCARE TO REPORT THAT THE LEFT ATRIAL INTERNAL DIAMETER MEASUREMENT WAS DISPLAYING INCORRECTLY ON THE CARDIO CLINICAL REPORT. THIS MAPPING STRING WAS UPDATED AND THE ISSUE WAS CONFIRMED TO BE RESOLVED. NO FURTHER ACTION IS NECESSARY AT THIS TIME. THIS HAS
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11269980 ↗MalfunctionDec 31, 2020Application Program Problem: Parameter Calculation Error; Application Program Problem: Parameter Calculation Error
MERGE CARDIO IS A SYSTEM INTENDED TO BE USED TO ACQUIRE, STORE, PRINT, TRANSFER, AND ARCHIVE CLINICAL INFORMATION FROM MERGE HEALTHCARE AND OTHER VENDORS SYSTEMS INCLUDING IMAGES, HEMODYNAMIC STUDIES AND REPORTS, MEASUREMENTS (VIA IMPORT FROM DICOM STRUCTURED REPORTING, TEXT FILES OR OPTICAL CHARACTER RECOGNITION OF MEASUREMENTS CAPTURED ON IMAGES) AND CARDIOLOGY SIGNAL (WAVEFORM) DATA. MERGE CARDIO IS INTENDED TO ALLOW USERS TO REVIEW DIAGNOSTIC AND NON-DIAGNOSTIC QUALITY IMAGES, ANNOTATE STUDIES, PERFORM DIGITAL SUBTRACTION ON IMAGES, TO PERFORM QUANTITATIVE MEASUREMENTS ON IMAGES (INCLUDING BUT NOT LIMITED TO QUANTITATIVE CORONARY ANALYSIS, LEFT VENTRICULAR ANALYSIS, TIME, AREA, LENGTH, VELOCITY, ANGLE, VOLUME, AND VELOCITY-TIME INTEGRALS), TO GENERATE PHYSICIAN GENERATED CLINICAL REPORTS (VIA STRUCTURE REPORTING AND TEMPLATE BASED TOOLS), AND TO STORE THIS INFORMATION IN A DATABASE. ON (B)(6) 2020, AN INTERNAL INVESTIGATION REVEALED THAT DUE TO TWO MEASUREMENTS BEING MAPPED TO THE SAME CODE, ONE MEASUREMENT COULD OVERWRITE THE OTHER IN THE CLINICAL CARDIO REPORT. THE "MR FLOW RATE" MEASUREMENT AND THE "MAX VELOCITY (MR)" MEASUREMENT WERE BOTH MAPPED TO CPCODE (10607). INTERNAL
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11101546 ↗
Other Merge Healthcare Solutions Inc. products
All Merge Healthcare Solutions Inc. devices →Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page