2 open recalls name at least one Microstream Advance model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.

Adverse event reports
38
Deaths reported
0
Injuries reported
9
Recalls
2

We found 13 models of Microstream Advance by Oridion Medical 1987 Ltd. in the FDA's device registry (GUDID). Together they are named in 38 adverse event reports in the FDA's MAUDE database, received between Apr 11, 2022 and May 7, 2026 — classified as 9 injuries, 29 malfunctions.

The most frequently reported specific device problem is “Failure to Analyze Signal” (11 reports).

2 FDA recall records name at least one of these models by its device identifier, 2 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works

Reports received per month, all models

Nov 2023: 0 reportsDec 2023: 4 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 6 reportsJun 2025: 1 reportsJul 2025: 10 reportsAug 2025: 1 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 3 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports20242025202610
Last 36 months. The most recent month may be incomplete.

Microstream Advance recalls

FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.

  1. Feb 17, 2025Class IIOpen, Classified

    Neonatal-Infant and Adult-Pediatric CO2 Sampling Line/Airway Adapter/CO2 Oral-Nasal Filter Line/Intubated Filter (CO2) Line device users may experience difficulty/inability to disconnect adapter from endotracheal tube for procedures (e.g. suctioning), may cause treatment delay and/or unintended extubation, which could lead to respiratory failure, hypoxia, aspiration, and/or low oxygen saturation.

    Z-1385-2025 · Root cause: Labeling design · names 3 of these models · Recall details · FDA record ↗

  2. Feb 17, 2025Class IIOpen, Classified

    Neonatal-Infant and Adult-Pediatric CO2 Sampling Line/Airway Adapter/CO2 Oral-Nasal Filter Line/Intubated Filter (CO2) Line device users may experience difficulty/inability to disconnect adapter from endotracheal tube for procedures (e.g. suctioning), may cause treatment delay and/or unintended extubation, which could lead to respiratory failure, hypoxia, aspiration, and/or low oxygen saturation.

    Z-1384-2025 · Root cause: Labeling design · names 8 of these models · Recall details · FDA record ↗

Most reported Microstream Advance problems

Device problems

  • Failure to Analyze Signal11
  • Difficult or Delayed Separation8
  • Mechanical Problem6
  • Unable to Obtain Readings5
  • Filtration Problem4
  • Low Readings3
  • Appropriate Device Problem Term/Code Not Available2
  • Device Damaged Prior to Use2

Patient problems

  • No Clinical Signs, Symptoms or Conditions25
  • Unintended Extubation8
  • Insufficient Information2
  • Unspecified Tissue Injury2
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Cardiac Arrest1
  • Foreign Body In Patient1

Microstream Advance models

13 models, most reported first. Each model has its own page with its reports, recalls and device details.

Recent Microstream Advance adverse event reports

The 15 most recent reports across all models, in the reporter's own words as published by the FDA.

Other Oridion Medical 1987 Ltd. products

All Oridion Medical 1987 Ltd. devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page