RELIEVA SPINPLUS NAVRecalls & reported problems across all models
Acclarent, Inc. · 2 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 29
- Deaths reported
- 1
- Injuries reported
- 5
- Recalls
- 0
We found 2 models of RELIEVA SPINPLUS NAV by Acclarent, Inc. in the FDA's device registry (GUDID). Together they are named in 29 adverse event reports in the FDA's MAUDE database, received between Aug 30, 2018 and Sep 25, 2026 — classified as 1 death, 5 injuries, 23 malfunctions.
The most frequently reported specific device problem is “Incorrect Interpretation of Signal” (18 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Most reported RELIEVA SPINPLUS NAV problems
Device problems
- Incorrect Interpretation of Signal18
- Adverse Event Without Identified Device or Use Problem3
- Patient Device Interaction Problem3
- Insufficient Device Problem Information2
- Deformation Due to Compressive Stress1
- Material Rupture1
- Material Separation1
- Tear, Rip or Hole in Device Packaging1
Patient problems
- No Clinical Signs, Symptoms or Conditions22
- Cerebrospinal Fluid Leakage2
- Perforation of Vessels2
- Stroke/CVA2
- Asthma1
- Cardiac Arrest1
- No Code Available1
- No Consequences Or Impact To Patient1
RELIEVA SPINPLUS NAV models
2 models, most reported first. Each model has its own page with its reports, recalls and device details.
- RELIEVA SPINPLUS NAV RSP0616MFSNINSTRUMENT, ENT MANUAL SURGICAL1 death27 reports
- RELIEVA SPINPLUS NAV RSP0616MFSNZEar, Nose, and Throat Stereotaxic Instrument2 reports
Recent RELIEVA SPINPLUS NAV adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionSep 25, 2026Incorrect Interpretation of Signal
It was reported that initially the SPINPLUS NAV 6x16mm 3 Guide (b)(6) "was tracking accurately until midway through the case it stopped being accurate." Inaccuracy was reportedly determined by "trying to get into frontal and showed the balloon in the brain. Inaccuracy was observed posterior. It was "off by 5 mm or more and then stopped tracking altogether". Staff opened a new SPINPLUS which was accurate from then on. There was no patient injury or delay in surgery.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50893073 ↗DeathFeb 12, 2026Adverse Event Without Identified Device or Use Problem
MalfunctionJan 19, 2026Deformation Due to Compressive Stress
IT WAS REPORTED THAT DURING AN IN-OFFICE BALLOON SINUPLASTY PROCEDURE, THE TIP OF THE NAVIGATED WIRE OF THE SPINPLUS NAV 6X16MM 3 GUIDE (RSP0616MFSNZ) BECAME TOO KINKED FOR THE SURGEON TO COMPLETE THE PROCEDURE WITH THE DEVICE. "IT WAS PERMANENTLY KINKED IN THREE DIFFERENT LOCATIONS." IT WAS REPORTED THAT THERE WAS A 30 MINUTE DELAY DURING THE PROCEDURE. NO PATIENT ADVERSE EVENT OCCURRED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24112340 ↗InjuryFeb 12, 2025Patient Device Interaction Problem; Patient Device Interaction Problem
IT WAS REPORTED THAT DURING A TRUDI¿ NAVIGATION CASE IN THE OPERATING ROOM (OR), A CEREBROSPINAL FLUID OR CSF LEAK WAS NOTICED IN THE PATIENT. THE CALLER REPORTED THAT THERE WERE NO ISSUES OR ERRORS OBSERVED ON THE TRUDI¿ NAVIGATION SYSTEM. THE CALLER REPORTED THAT DURING THE PROCEDURE, THE PHYSICIAN HAD NOTICED A SMALL CEREBROSPINAL FLUID LEAK IN THE PATIENT. THE CALLER REPORTED THAT THE MEDICAL INTERVENTION PROVIDED TO THE PATIENT WAS A MUCOSAL PATCH OR GRAFT. THE CALLER REPORTED THAT THE PATIENT WAS THEN SENT TO THE HOSPITAL FOR FURTHER MONITORING. THE CALLER WAS UNABLE TO CONFIRM IF THE PATIENT IS IN STABLE CONDITION AT THIS TIME. IT WAS ALSO REPORTED THAT THE FOLLOWING ACCLARENT PRODUCTS WERE USED DURING THIS CASE: RELIEVA SPINPLUS® NAV BALLOON - RSP0616MFSN, TRUDI¿ PROBE (70 DEGREE) - TDP0705, TRUDI¿ NAV SUCTION DEVICE (0 DEGREE) - TDNS000Z, TRUDI¿ NAV SUCTION DEVICE (70 DEGREE) - TDNS070Z, TRUDI¿ NAV SUCTION DEVICE (90 DEGREE) - TDNS090Z.
Patient problems: Cerebrospinal Fluid Leakage
MAUDE report 21367347 ↗MalfunctionFeb 7, 2025Incorrect Interpretation of Signal; Incorrect Interpretation of Signal
THE HEALTHCARE PROFESSIONAL REPORTED THAT MIDWAY THROUGH A PRIMARY HYBRID FUNCTIONAL ENDOSCOPIC SINUS SURGERY (FESS) WITH BALLOON DILATION IN THE OPERATING ROOM, A TRUDI SYSTEM LOST ACCURACY. IT WAS STATED THAT THE TRUDI SUCTION DEVICE (TDNS000Z, LOT UNKNOWN), THE TRUDI SHAVER BLADE ¿ STRAIGHT, DOUBLE SERRATED, 4.0MM X 110MM (TSB4STR, UNKNOWN LOT) AND A RELEVA SPINPLUS NAVIGATION BALLOON SINUPLASTY SYSTEM, 6X16MM (RSP0616MFSN, UNKNOWN LOT) WERE INACCURATELY DISPLAYED ON THE TRUDI SYSTEM. THE CALLER STATED THAT THE ISSUE OCCURRED THREE TIMES DURING THE CASE. THE PATIENT WAS REREGISTERED THE FIRST TWO TIMES THE ISSUE OCCURRED, AND THE ISSUE WOULD BE RESOLVED. THE THIRD TIME THAT THE ISSUE OCCURRED, THE PROCEDURE WAS CONTINUED WITHOUT RESOLUTION. THERE WAS NO ALLEGATION THAT A DEATH OR SERIOUS INJURY OCCURRED DUE TO THE USE OF THE PRODUCT. THERE WAS NO REPORT OF THE PATIENT REQUIRING MEDICAL INTERVENTION. NON ACCLARENT DEVICES WERE USED. ADDITIONAL EVENT INFORMATION RECEIVED ON 04-FEB-2025 INDICATED THAT THE CUSTOMER CONFIRMED ACCURACY USING THE REGISTRATION PROBE AFTER REGISTRATION PROCESS WAS COMPLETED. THE CUSTOMER CONFIRM ACCURACY MULTIPLE TIMES IN THE KNOWN LANDMARKS IN ENDOSCOPI
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21334872 ↗MalfunctionMay 6, 2024Incorrect Interpretation of Signal; Incorrect Interpretation of Signal
THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING A PRIMARY HYBRID BILATERAL FUNCTIONAL ENDOSCOPIC SINUS SURGERY (FESS) AND BALLOON SINUPLASTY (BSP) PROCEDURE ON (B)(6) 2024, UPON STARTING THE TRUDI SYSTEM, THE CONSOLE WAS DISPLAYED AS RED AND AN INSTRUMENT HUB CALIBRATION ERROR (UNKNOWN CODE) WAS DISPLAYED ON THE TRUDI SYSTEM. THE TRUDI SYSTEM WAS REBOOTED AND THE ISSUE WAS RESOLVED. THE PROCEDURE RESUMED. IT WAS ALSO REPORTED THAT THE ACCURACY WAS OFF BY APPROXIMATELY 4MM. THE 0° TRUDI NAV SUCTION DEVICE (TDNS000Z / LOT# UNKNOWN), 4.0MM ¿ STRAIGHT (0°) TRUDI NAVIGATION SHAVER BLADE (TSB4STR / LOT# UNKNOWN), AND 6MM X 16MM RELIEVA SPINPLUS NAVIGATION BALLOON SINUPLASTY SYSTEM (RSP0616MFSN / LOT# UNKNOWN) HAD ACCURACY ISSUES. NO TROUBLESHOOTING WAS PERFORMED. THE PROCEDURE WAS CONTINUED WITHOUT RESOLUTION. THERE WAS NO NEGATIVE PATIENT IMPACT REPORTED. THERE WAS NO MEDICAL INTERVENTION REQUIRED NOR REPORTED AS A RESULT OF THE REPORTED ISSUE WITH ACCURACY.ON 03-MAY-2024, ADDITIONAL INFORMATION WAS RECEIVED. PER THE ADDITIONAL INFORMATION, ACCURACY WAS CONFIRMED BEFORE USING THE REGISTRATION PROBE AFTER THE REGISTRATION PROCESS WAS COMPLETED. ACCURACY WAS CONFIRMED VIA KNOWN LAND
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19256245 ↗MalfunctionApr 25, 2024Incorrect Interpretation of Signal; Incorrect Interpretation of Signal
THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING A PRIMARY HYBRID FUNCTIONAL ENDOSCOPIC SINUS SURGERY (FESS) PROCEDURE, THE SPIN PLUS NAV BALLOON (RSP0616MFSN, LOT UNKNOWN) WAS BEING DISPLAYED INAPPROPRIATELY ON THE TRUDI SYSTEM VERSION 2.3.2.3 (400089). THE CALLER NOTED THAT THE ACCURACY AND LOCATION OF THE BALLOON WAS NOT DISPLAYED PROPERLY. TO TROUBLESHOOT, THE CABLE WAS RESEATED WITHOUT RESOLUTION. THE DONGLE WAS EXCHANGED WITHOUT RESOLUTION. THE BALLOON WAS EXCHANGED, AND THE ISSUE RESOLVED. THE CASE CONTINUED. THERE WAS NO ALLEGATION THAT A DEATH OR SERIOUS INJURY OCCURRED DUE TO THE USE OF THE PRODUCT. THERE WAS NO REPORT OF THE PATIENT REQUIRING MEDICAL INTERVENTION AS A RESULT OF THE ALLEGED PRODUCT ISSUE. ADDITIONAL EVENT INFORMATION WAS RECEIVED ON 03-APR-2024 INDICATING THAT THERE WAS NO MOVEMENT WITH THE PATIENT TRACKER OR THE PATIENT TRACKER CABLE UNDER TENSION IN RELATION TO THIS EVENT. NO MORE THAN ONE CT SCAN WAS ATTEMPTED TO BE USED WITH ONE DEVICE. THE CT IMAGE USED AS THE PRIMARY IMAGE. THERE WAS NO FERROMAGNETIC MATERIAL PLACED WITHIN THE TRUDI ZONE. THE EMITTER PAD NOR WAS PATIENT MOVED. WHEN THE ACCURACY ISSUE WAS OBSERVED, THE COLOR ON THE BAR WAS ¿GREEN¿ ON
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19180136 ↗InjuryMar 22, 2024Insufficient Device Problem Information; Patient Device Interaction Problem; Insufficient Device Problem Information; Patient Device Interaction Problem
IT WAS REPORTED THAT ON (B)(6) 2022, DURING A BALLOON SINUPLASTY (BSP) PROCEDURE, THE PATIENT SUSTAINED AN INJURY TO HER CAROTID ARTERY THAT RESULTED IN HER SUFFERING A CATASTROPHIC STROKE. THE REPORTED DEVICES USED DURING THE PROCEDURE WERE: A RELIEVA TRACT BALLOON (RT1640A / 211202A-PC), TWO 6MM X 16MM RELIEVA SPINPLUS NAVIGATION BALLOON SINUPLASTY SYSTEM (RSP0616MFSN), ONE FROM LOT 220419A-PC AND ONE FROM LOT 220504A-PC, A DISPOSABLE TRUDI PROBE 0-DEGREE, 5IN (TDP0005 / 210201B-PC), AN ACCLARENT BALLOON INFLATION DEVICE (BID30 / 96375250), AND A TRUDI NAV CABLE (TDNC001 / 211206C-PC) AND THE TRUDI NAVIGATION SYSTEM. IT IS REPORTED THAT THE PATIENT BELIEVED THAT THE ACCLARENT NAVIGATION BALLOON DILATION SYSTEM AND ITS COMPONENT PARTS, INCLUDING ANY AI (ARTIFICIAL INTELLIGENCE SOFTWARE) MAY HAVE MALFUNCTIONED AND FAILED TO PERFORM AS INTENDED DURING THE PROCEDURE, AND THAT AS A RESULT, THE PATIENT¿S CAROTID ARTERY WAS INJURED.
Patient problems: Perforation of Vessels; Stroke/CVA
MAUDE report 18963025 ↗InjuryMar 22, 2024Insufficient Device Problem Information; Patient Device Interaction Problem; Insufficient Device Problem Information; Patient Device Interaction Problem
IT WAS REPORTED THAT ON (B)(6) 2022, DURING A BALLOON SINUPLASTY (BSP) PROCEDURE, THE PATIENT SUSTAINED AN INJURY TO HER CAROTID ARTERY THAT RESULTED IN HER SUFFERING A CATASTROPHIC STROKE. THE REPORTED DEVICES USED DURING THE PROCEDURE WERE: A RELIEVA TRACT BALLOON (RT1640A / 211202A-PC), TWO 6MM X 16MM RELIEVA SPINPLUS NAVIGATION BALLOON SINUPLASTY SYSTEM (RSP0616MFSN), ONE FROM LOT 220419A-PC AND ONE FROM LOT 220504A-PC, A DISPOSABLE TRUDI PROBE 0-DEGREE, 5IN (TDP0005 / 210201B-PC), AN ACCLARENT BALLOON INFLATION DEVICE (BID30 / 96375250), AND A TRUDI NAV CABLE (TDNC001 / 211206C-PC) AND THE TRUDI NAVIGATION SYSTEM. IT IS REPORTED THAT THE PATIENT BELIEVED THAT THE ACCLARENT NAVIGATION BALLOON DILATION SYSTEM AND ITS COMPONENT PARTS, INCLUDING ANY AI (ARTIFICIAL INTELLIGENCE SOFTWARE) MAY HAVE MALFUNCTIONED AND FAILED TO PERFORM AS INTENDED DURING THE PROCEDURE, AND THAT AS A RESULT, THE PATIENT¿S CAROTID ARTERY WAS INJURED.
Patient problems: Perforation of Vessels; Stroke/CVA
MAUDE report 18962997 ↗MalfunctionDec 14, 2023Material Separation; Material Separation
THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING A HYBRID FUNCTIONAL ENDOSCOPIC SINUS SURGERY (FESS) PROCEDURE, RIGHT AFTER DILATING THE RIGHT SPHENOID SINUS, WHEN THE 6MM X 16MM RELIEVA SPINPLUS NAVIGATION BALLOON SINUPLASTY SYSTEM (RSP0616MFSN / 231002A-PC) WAS REMOVED, IT BROKE IN HALF ACROSS THE DIAMETER AND SEPARATED FROM THE FLEXIBLE CATHETER. IT WAS REPORTED THAT TO TROUBLESHOOT, THE RELIEVA SPINPLUS NAV WAS REPLACED, THE ISSUE WAS RESOLVED AND THE PROCEDURE WAS RESUMED. THERE WAS NO REPORT OF ANY NEGATIVE PATIENT IMPACT. ON 08-DEC-2023, ADDITIONAL INFORMATION WAS RECEIVED. PER THE INFORMATION, THE SPINPLUS NAV WAS USED TO TREAT LEFT SPHENOID SINUS FIRST; THE RIGHT SPHENOID SINUS WAS DILATED SECOND. IT WAS NOT KNOWN IF THE SPINPLUS NAV BROKE AFTER IT WAS REMOVED FROM THE PATIENT¿S ANATOMY; PER THE ACCLARENT CLINICAL REPRESENTATIVE, ¿IT WAS BROUGHT TO MY ATTENTION OUTSIDE OF THE PATIENT¿S ANATOMY.¿ IT WAS UNKNOWN IF THE BALLOON CATHETER COMPONENT BROKE INTO TWO OR MORE PIECES. IT WAS NOT KNOWN IF THERE WERE ANY FRAGMENTS OF THE BALLOON CATHETER INSIDE THE PATIENT¿S RIGHT SPHENOID, ¿THE DR. DID A VISUAL EXAM UNDER DIRECT ENDOSCOPE VISUALIZATION. AND PROCEEDED WITH THE CASE.¿ I
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18332266 ↗MalfunctionNov 3, 2023Incorrect Interpretation of Signal; Incorrect Interpretation of Signal
THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING AN IN-OFFICE PRIMARY BALLOON SINUPLASTY (BSP) PROCEDURE USING A 6MM X 16MM RELIEVA SPINPLUS NAVIGATION BALLOON SINUPLASTY SYSTEM (RSP0616MFSN / 230911A-PC) A DAY AFTER THE COMPLETION OF A SOFTWARE UPDATE ON THE TRUDI NAVIGATION SYSTEM (FG200000 / SERIAL #: (B)(6)) , THE ACCURACY SEEMED TO BE OFF ACCORDING TO THE PHYSICIAN. IT WAS REPORTED THAT THE ACCURACY WAS OFF ¿BY MULTIPLE MILLIMETERS.¿ REBOOTING DID NOT RESOLVE THE ISSUE. THE COMPLAINT BALLOON WAS REPLACED AND THE ACCURACY ¿SEEMED TO BE IMPROVED BUT NOT COMPLETELY RESOLVED.¿ THERE WAS NO REPORT OF ANY NEGATIVE PATIENT IMPACT. ON 24-OCT-2023, ADDITIONAL INFORMATION WAS RECEIVED. PER THE INFORMATION, COMPUTED TOMOGRAPHY (CT) IMAGE WAS USED AS THE PRIMARY IMAGE. THE NUMBER OF SLICES CONTAINED ON THE CT SCAN IS NOT KNOWN. NOT MORE THAN ONE C SCAN WAS ATTEMPTED TO BE USED WITH THE DEVICE. THE PATIENT TRACKER DID NOT MOVE AND THE PATIENT TRACKER CABLE WAS NOT UNDER TENSION IN RELATION TO THE REPORTED ACCURACY BEING OFF ISSUE. THERE WAS NO FERROMAGNETIC MATERIAL PLACED WITHIN THE TRUDI ZONE. THE EMITTER PAD DID NOT MOVE. THE PATIENT DID NOT MOVE. WHEN THE ACCURACY ISSUE WAS OBSERVED, T
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18070079 ↗MalfunctionApr 5, 2023Incorrect Interpretation of Signal; Incorrect Interpretation of Signal
THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING A REVISION HYBRID FUNCTIONAL ENDOSCOPIC SINUS SURGERY (FESS) PROCEDURE ON (B)(6) 2023, THERE WAS ACCURACY ISSUES WITH THE PATIENT TRACKER. WHEN THE PATIENT TRACKER WAS TAKEN OFF THE TEGADERM, IT LOOKED LIKE THERE WAS A TEAR ON THE RUBBER PIECE ON THE TRACKER. THE VISUAL LINE OF THE PATIENT AND THE VISUALS APPEARED OFF. IT WAS REPORTED THAT TO TROUBLESHOOT, THE 6MM X 16MM RELIEVA SPINPLUS NAVIGATION BALLOON SINUPLASTY SYSTEM (B)(4) WITHOUT RESOLUTION. THE PATIENT WAS RE-REGISTERED SEVERAL TIMES; THE PATIENT TRACKER WAS TAKEN OFF THE TEGADERM AND SAW THE SMALL TEAR IN THE TRACKER ITSELF. THERE WAS NO REPORT OF ANY NEGATIVE PATIENT IMPACT. THE COMPLAINT DEVICE IS REPORTED AS NOT AVAILABLE TO BE RETURNED FOR EVALUATION AND ANALYSIS. ON (B)(6) 2023, ADDITIONAL INFORMATION WAS RECEIVED. THE INFORMATION INDICATED THAT WHEN THE ACCURACY ISSUE WAS OBSERVED, THE COLOR OF THE BAR BELOW THE BALLOON ICON ON THE TRUDI SYSTEM MONITOR WAS GREEN. THERE WAS NO ERROR MESSAGE ON THE TRUDI NAV MONITOR FOR THE DEVICE. THE DEVICE WAS PLUGGED IN THE FIRST TIME AFTER REGISTRATION. THE INFORMATION INDICATED THAT THE PATIENT TRACKER DID NOT MOVE; THE PATIENT T
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16686722 ↗MalfunctionMar 10, 2023Incorrect Interpretation of Signal; Incorrect Interpretation of Signal
THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING A PRIMARY HYBRID FUNCTIONAL ENDOSCOPIC SINUS SURGERY (FESS) PROCEDURE, ¿UPON USING THE BALLOON CATHETER [A 6MM X 16MM RELIEVA SPINPLUS NAVIGATION BALLOON SINUPLASTY SYSTEM (RSP0616MFSN / 221130B-PC)] IT WAS OBSERVED THAT IT WAS UNABLE TO NAVIGATE CORRECTLY.¿ THE BALLOON CATHETER WAS REPLACED, THE ISSUE WAS RESOLVED AND THE PROCEDURE CONTINUED. THERE WAS REPORT OF ANY NEGATIVE PATIENT IMPACT. ON 23-FEB-2023, ADDITIONAL INFORMATION WAS RECEIVED. THE INFORMATION PROVIDED CLARIFICATION TO THE EVENT DESCRIPTION, ¿UNABLE TO NAVIGATE CORRECTLY¿ AS FOLLOWS, ¿NO ERROR MESSAGE, THE PHYSICIAN COULD TELL THE ACCURACY WAS OFF. NO OTHER INSTRUMENTS HAD BAD ACCURACY.¿ THERE WAS NO DIFFICULTY EXPERIENCED DURING THE ADVANCEMENT OF THE DEVICE INSIDE THE PATIENT¿S ANATOMY. THERE WAS NO DAMAGE OBSERVED TO THE DEVICE. WHEN THE ACCURACY ISSUE WAS OBSERVED, THE ICON ON THE TRUDI SYSTEM WAS GREEN. THE DEVICE WAS PLUGGED IN AFTER REGISTRATION. THE PATIENT TRACKER WAS NOT MOVED AND THE PATIENT TRACKER CABLE WAS NOT UNDER TENSION IN RELATION TO THE REPORTED ACCURACY ISSUE. COMPUTER TOMOGRAPHY (CT) IMAGE WAS THE PRIMARY IMAGE USED; THE CT SLICES WERE 0.5MM. IT
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16524735 ↗MalfunctionFeb 27, 2023Incorrect Interpretation of Signal; Incorrect Interpretation of Signal
THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING A PRIMARY HYBRID FUNCTIONAL ENDOSCOPIC SINUS SURGERY PROCEDURE ON (B)(6) 2023, THE TRUDI NAVIGATION SYSTEM (S/N: (B)(4)) WAS SHOWING INACCURACIES AFTER SEVERAL ROUNDS OF REGISTRATION. A DISPOSABLE PATIENT TRACKER WAS INITIALLY USED, AND AFTER INACCURACIES WERE OBSERVED, A DECISION WAS MADE TO SWITCH TO THE REUSABLE PATIENT TRACKER. A SPINPLUS NAVIGATION BALLOON SINUPLASTY SYSTEM (RSP0616MFSN / LOT# UNKNOWN) AND A 0° TRUDI NAV SUCTION DEVICE (TDNS000Z / 2111120) WERE USED. ONCE REGISTERED, THE INACCURACIES CONTINUED. REGISTRATION WAS DONE FOR A THIRD TIME WITH CONTINUED INACCURACY. THE PHYSICIAN WAS UNABLE TO DO ALL THEY WANTED TO DO WITH NAVIGATION DURING THE PROCEDURE; THEREFORE, THE NAVIGATION PORTION OF THE PROCEDURE WAS ABORTED. AFTER THE PROCEDURE, THE ACCLARENT REPRESENTATIVE REPORTEDLY SPENT 2.5 HOURS TROUBLESHOOTING WITH A MODEL HEAD. A NEW PATIENT PROBE, A REUSABLE PATIENT TRACKER, A NEW SPINPLUS NAVIGATION BALLOON SINUPLASTY SYSTEM (RSP0616MFSN) WERE USED DURING THE TROUBLESHOOTING; IT WAS REPORTED THAT THE 0° TRUDI NAV SUCTION DEVICE (TDNS000Z / 2111120) USED DURING THE PROCEDURE WAS RE-STERILIZED AND WAS USED DURING THE T
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16449033 ↗MalfunctionNov 21, 2022Incorrect Interpretation of Signal; Incorrect Interpretation of Signal
THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING A FUNCTIONAL ENDOSCOPIC SINUS SURGERY (FESS) PROCEDURE WITH BALLOON SINUPLASTY, THE FOLLOWING DEVICES WERE USED: A 6MM X 16MM RELIEVA SPINPLUS NAVIGATION BALLOON SINUPLASTY SYSTEM (RSP0616MFSN / LOT# UNKNOWN), A 0° TRUDI NAV SUCTION DEVICE (TDNS000Z / LOT#: UNKNOWN), AND AN UNKNOWN CURVE SUCTION DEVICE (CATALOG / LOT# UNKNOWN) WERE USED AND THERE WERE ACCURACY ISSUES WITH ALL OF THE DEVICES USED WITH THE TRUDI SYSTEM DURING THE ENTIRE PROCEDURE. THE HEALTHCARE PROFESSIONAL REPORTED THAT THE ACCURACY ISSUE WAS OFF FROM THE START OF THE PROCEDURE. THE DEVICES WERE RE-REGISTERED TWO OR THREE TIMES WITHOUT RESOLUTION. THE DEVICES WERE DISPLAYED ON THE TRUDI SYSTEM AS 3 ¿ 4MM OFF. THE PROCEDURE WAS ABLE TO BE COMPLETED WITHOUT ANY NEGATIVE IMPACT TO THE PATIENT. THE DEVICES ARE REPORTEDLY NOT AVAILABLE TO BE RETURNED. ON 21-NOV-2022, ADDITIONAL INFORMATION WAS RECEIVED. THE INFORMATION INDICATED THAT WHEN THE ACCURACY ISSUE WAS OBSERVED, THE ICON ON THE TRUDI SYSTEM WAS GREEN. THERE WAS NO ERROR MESSAGE ON THE TRUDI NAV MONITOR FOR THE DEVICE. THE DEVICES WERE PLUGGED IN INITIALLY AFTER FIRST REGISTRATION BUT WERE ALREADY PLUGGED IN FOR N
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15840773 ↗
Other Acclarent, Inc. products
All Acclarent, Inc. devices →Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page