Covidien Endo GIA Ultra Universal Standard Stapler Handle recallZ-0820-2016 · Medtronic · initiated Dec 2, 2015

Class II Terminated All recalls posted in February 2016

Is my device affected?

  1. Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
  2. If yours is listed, follow the instructions from Medtronic or your healthcare provider. The company's action is summarized under what the company is doing.
  3. Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.

Where to find your model and lot numbers · What recall classes and statuses mean

Why it was recalled

Staplers fail to fire or partially fire and reports of the instrument articulating lever disengaging during use

FDA root cause category: Process control

What the company is doing

Medtronic sent an Urgent Medical Device Recall letters dated December 2 2015 and an Updated Urgent Medical Device Recall letter dated January 13, 2016, to affected customers, via Federal Express. The letter identified the affected product, problem and actions to be taken. Customers were instructed to discontinue use of the product and return all inventory to Medtronic (Covidien), 195 McDermott Road, North Haven, CT 06473. For questions or concerns, please do not hesitate to contact your Medtronic representative or Customer Service at (800) 882-5878.

Recall details

Recall number
Z-0820-2016
Recall class
Class II
Status
Terminated
Initiated by the company
Dec 2, 2015
Posted by the FDA
Feb 18, 2016
Recalling firm
Medtronic
Quantity
1,102,166 units
Product code
GDW
FDA submissions
K111825
Distribution
Worldwide Distribution - US Nationwide and the countries of Canada, Albania, ALGERIA, Argentina, Australia, Austria, Azerbaijan, Bahrain, Belgium, Bolivia, Bosnia and Herzegovina, Brazil, Bulgaria, Chile, Colombia, Costa Rica, Croatia, Cyprus, Czech Republic, Denmark, Ecuador, Egypt, El Salvador, Estonia, Finland, France, Gabon, Georgia, Germany, Greece, Greece, Guatemala, Honduras, Hungary, Iceland, Iran, Ireland, Israel, Italy, Japan, Jordan, Kazakhstan, Kenya, Kuwait, Latvia, Lebanon, Libya, Lithuania, Luxembourg, Macedonia, Mauritius, Mexico, Monaco, Montenegro, Morocco, Namibia, Netherlands, Nicaragua, Nigeria, Norway, Panama, Paraguay, Peru, Poland, Portugal, Romania, Russia, Russian Federation, Saudi Arabia, Serbia, Slovakia, Slovenia, South Africa, Spain, Sweden, Switzerland, Tunisia, Turkey, UAE, Ukraine, United Kingdom, Uruguay, Venezuela, and Zimbabwe.

Product description

Covidien Endo GIA Ultra Universal Standard Stapler Handle Ref: EGIAUSTND Product Usage: The Endo GIA Ultra Universal Short, Endo GIA Ultra Universal and Endo GIA Ultra Universal XL staplers have applications in abdominal, gynecologic, pediatric and thoracic surgery for resection, transection and creation of anastomosis. It may be used for transection and resection of liver substance, hepatic vasculature and biliary structures. The Endo GIA Ultra Universal Short, Endo GIA Ultra Universal and Endo GIA Ultra Universal XL staplers when used with the Endo GIA curved tip single use reloads can be used to blunt dissect or separate target tissue from other tissue.

Code information (models, lots, serial numbers)

Show the full code information (1k characters)

RANGES OF LOT NUMBERS (all lot numbers within each range are affected) Lot # starting with P3C through P5B0521X P5D0410X through P5D0411X P5D0823X through P5D0829X  P5E0080X through P5E0082X  P5E0317X through P5E0320X  P5E0322X through P5E0324X  P5F0001X through P5F0002X  INDIVIDUAL LOT NUMBERS (in addition to ranges) P5C0239X, P5C0241X, P5C0508X, P5C0510X, P5C0512X, P5C0597X P5C0599X, P5C0601X, P5C0603X, P5C0684X, P5C0803X, P5C0805X, P5C0807X. P5E0527X, P5E0529X   P5D0067X, P5D0069X , P5D0073X, P5D0170X, P5D0413X, P5D0415X ,P5D0417X, P5D0419X, P5D0447X, P5D0623X, P5D0624X ,P5D0626X, P5D0628X   P5D0630X, P5E0525X, P5F0004X, P5F0006X, P5F0008X, P5F0010X, P5F0014X, P5F0017X, P5F0019X, P5F0021X, P5F0213X, P5F0217X

Other devices under the same FDA submission

77 devices cleared under K111825 — the recall does not name any of them by identifier. One submission often covers many models, so they may or may not be affected.

Other products in the same recall event

The FDA groups related products into one recall event (event 72749).