Sheridan Preformed Cuffed Nasal Tracheal Tube, 7.5 mm recallZ-0128-2007 · Teleflex Medical · initiated Sep 27, 2006
Terminated All recalls posted in November 2006
Is my device affected?
- Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
- If yours is listed, follow the instructions from Teleflex Medical or your healthcare provider. The company's action is summarized under what the company is doing.
- Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.
Where to find your model and lot numbers · What recall classes and statuses mean
Why it was recalled
Biological indicator failed. Investigation eliminated all equipment and product related factors.
FDA root cause category: Other
What the company is doing
Teleflex Medical sent Urgent Medical Device Recall letters dated 9/27/06 via UPS overnight to the direct accounts, informing them that the product did not pass validated sterility test requirements, and requesting that they cease use of the affected units and return them to Teleflex Medical for replacement. If the accounts further distributed the product, they were requested to conduct a sub-recall of the affected units from their customers. The accounts were instructed to complete and return by fax the enclosed Acknowledgement & Stock Status Form, indicating the number of units being returned for replacement. Any questions were directed to Linda Todd at 1-800-334-9751, ext. 4951.
Recall details
- Recall number
- Z-0128-2007
- Recall class
- Not yet classified by the FDA
- Status
- Terminated
- Initiated by the company
- Sep 27, 2006
- Posted by the FDA
- Nov 2, 2006
- Recalling firm
- Teleflex Medical
- Quantity
- 990 units
- Product code
- BTR
- FDA submissions
- K822082
- Distribution
- Nationwide and Argentina, Canada, Chile, Japan, Malaysia, the Netherlands and New Zealand
Product description
Sheridan Preformed Cuffed Nasal Tracheal Tube, 7.5 mm; a Rx, sterile, single use tracheal tube; Hudson Respiratory Care Inc., Temecula, CA 92589-9020, Manufactured in Mexico; catalog number (REF) 5-22315
Code information (models, lots, serial numbers)
catalog number (REF) 5-22315, lot number 1189026
Other devices under the same FDA submission
60 devices cleared under K822082 — the recall does not name any of them by identifier. One submission often covers many models, so they may or may not be affected.
- HUDSON RCI IPN044731Teleflex Incorporated · Tube, tracheal (w/wo connector)42 reports
- HUDSON RCI IPN048896Teleflex Incorporated · Tube, tracheal (w/wo connector)2 deaths32 reports
- HUDSON RCI IPN044767Teleflex Incorporated · Tube, tracheal (w/wo connector)31 reports
- HUDSON RCI IPN048895Teleflex Incorporated · Tube, tracheal (w/wo connector)1 death27 reports
- HUDSON RCI IPN046756Teleflex Incorporated · Tube, tracheal (w/wo connector)25 reports
- HUDSON RCI IPN048873Teleflex Incorporated · Tube, tracheal (w/wo connector)25 reports
- HUDSON RCI IPN044732Teleflex Incorporated · Tube, tracheal (w/wo connector)21 reports
- HUDSON RCI IPN044730Teleflex Incorporated · Tube, tracheal (w/wo connector)20 reports
- HUDSON RCI IPN048874Teleflex Incorporated · Tube, tracheal (w/wo connector)20 reports
- HUDSON RCI IPN046759Teleflex Incorporated · Tube, tracheal (w/wo connector)19 reports
- HUDSON RCI IPN044768Teleflex Incorporated · Tube, tracheal (w/wo connector)17 reports
- HUDSON RCI IPN048897Teleflex Incorporated · Tube, tracheal (w/wo connector)15 reports
Other products in the same recall event
The FDA groups related products into one recall event (event 36426).
- Z-0125-2007 · TerminatedSheridan Sher-I-Bronch Endobronchial Tube, Left-Sided, 37 Fr, 26 mm tracheal cuff, 19 mm bronchial cuff; a Rx, sterile, single use endobronchial tube with modified tip for left bro…
- Z-0126-2007 · TerminatedSheridan Preformed Uncuffed Oral Tracheal Tube, 3.0 mm; a Rx, sterile, single use tracheal tube; Hudson Respiratory Care Inc., Temecula, CA 92589-9020, Manufactured in Mexico; cata…
- Z-0127-2007 · TerminatedSheridan Preformed Cuffed Oral Tracheal Tube, 5.0 mm; a Rx, sterile, single use tracheal tube; Hudson Respiratory Care Inc., Temecula, CA 92589-9020, Manufactured in Mexico; catalo…
Sources and updates
- Recall record: FDA Medical Device Recalls, file dated Oct 16, 2026 · View the FDA recall notice ↗
- Devices: FDA GUDID, file dated Oct 13, 2026. Devices are linked when their identifier (with a valid check digit) appears in the recall's code information.
- Page last rebuilt: Oct 18, 2026. Text above is shown as published by the FDA.
How recalls are matched to devices · Editorial policy · Report an error on this page