Medical device recalls: August 2007
The FDA posted 91 medical device recall records in August 2007, from 61 recall events by 48 companies. 91 have not been classified yet.
Each product in a recall gets its own record, so one recall event can cover several records. What recall classes mean.
Companies with the most recall events
- Northwest Medical Physics Equipment Inc · 7 events, 7 records
- Sendx Medical Inc · 3 events, 3 records
- Abbott Diagnostic International, Ltd. · 2 events, 5 records
- Abbott Laboratories · 2 events, 5 records
- Boston Scientific Corporation · 2 events, 3 records
- Cardinal Health 303 Inc DBA Alaris Products · 2 events, 2 records
- Ross Products Division Abbott Laboratories · 2 events, 2 records
- Encore Medical, Lp · 1 event, 6 records
FDA root cause
- Other · 71
- Software design · 7
- Process control · 4
- Nonconforming Material/Component · 2
- Equipment maintenance · 2
- Device Design · 2
- Labeling mix-ups · 1
- Employee error · 1
Not yet classified (91)
The FDA has posted these records but has not published a class for them yet.
- Z-1213-2007 · Smiths Medical MD, Inc. · posted Aug 30, 2007 · Terminated
Smith Medical has become aware that an increase in pH may occur with some medications when instilled in the Affected Cassettes. Also, a small number of catheter occlusions have been reported from one customer when these Affected Cassettes have been used…
- Z-1214-2007 · Smiths Medical MD, Inc. · posted Aug 30, 2007 · Terminated
Smith Medical has become aware that an increase in pH may occur with some medications when instilled in the Affected Cassettes. Also, a small number of catheter occlusions have been reported from one customer when these cassettes have been used for…
- Z-1215-2007 · Smiths Medical MD, Inc. · posted Aug 30, 2007 · Terminated
Smith Medical has become aware that an increase in pH may occur with some medications when instilled in the Affected Cassettes. Also, a small number of catheter occlusions have been reported from one customer when these cassettes have been used for…
- Z-1195-2007 · Varian Medical Systems Inc · posted Aug 29, 2007 · Terminated
Patient positioning errors may occur because of mechanical variations during product installation.
- Z-1198-2007 · Abbott Laboratories · posted Aug 29, 2007 · Terminated
The product failed electrostatic discharge testing, which could result in product failure.
- Z-1199-2007 · Abbott Laboratories · posted Aug 29, 2007 · Terminated
The product failed electrostatic discharge testing, which could result in product failure.
- Z-1200-2007 · Abbott Laboratories · posted Aug 29, 2007 · Terminated
The product failed electrostatic discharge testing, which could result in product failure.
- Z-1201-2007 · Sendx Medical Inc · posted Aug 29, 2007 · Terminated
The ABL8O FLEX software version 1.10 contains errors in the derived parameter calculation for cBase(B,ox) and cBase(Ecf,ox). These incorrect calculations result in a mild to moderate lowering of the base excess value, the severity depending on the…
- Z-1202-2007 · Abbott Diagnostic International, Ltd. · posted Aug 29, 2007 · Terminated
Customers are receiving error codes (1062, 1063, 1113, & 1118) when running patient samples on the AxSYM Digoxin III assay.
- Z-1204-2007 · DeRoyal Lafollette · posted Aug 29, 2007 · Terminated
Packaging failure. Lack of sterility assurance
- Z-1205-2007 · DeRoyal Lafollette · posted Aug 29, 2007 · Terminated
Packaging failure. Lack of sterility assurance
- Z-1206-2007 · Spectrum Designs Inc · posted Aug 29, 2007 · Terminated
The product is being recalled because it was discovered the at least one unit in the lot contained a mismatched pair (two rights and no left). Since the lot was produced with equal numbers of pairs, it is assumed that one other unit was packaged with two…
- Multi-Link Vision RX Coronary Stent System, 3.0 x 15mm, Part number 1007848-15, lot number 7052951 ↗Z-1211-2007 · Abbott Vascular-Cardiac Therapies dba Guidant Corporation · posted Aug 29, 2007 · Terminated
The affected single lot did not meet an internal specification. One unit failed the test criteria for stent dislodgment testing.
- Z-1216-2007 · Summit Industries Inc. · posted Aug 29, 2007 · Terminated
The D800 Swivel Collimator may come loose from the tubestand and fall onto the x-ray table.
- Z-1217-2007 · Summit Industries Inc. · posted Aug 29, 2007 · Terminated
The E600 Swivel Collimator may come loose from the tubestand and fall onto the x-ray table.
- Z-1218-2007 · Summit Industries Inc. · posted Aug 29, 2007 · Terminated
The F100 Swivel Collimator may come loose from the tubestand and fall onto the x-ray table.
- Z-1196-2007 · Sendx Medical Inc · posted Aug 25, 2007 · Terminated
There have been reported experiences where waste fluids have sprayed out from the waste drain at the front of the ABL80 analyzer when excessive pressure builds within the waste line.
- Z-1197-2007 · Alcon Research, Ltd · posted Aug 25, 2007 · Terminated
Mislabeled: boxes actually contained Tri-Fact needles
- Z-1190-2007 · Volcano Corporation · posted Aug 23, 2007 · Terminated
During emissions testing, it was discovered that the product exceeds emissions limits for electromagnetic compatibility.
- Z-1193-2007 · Steris Corp · posted Aug 23, 2007 · Terminated
The cables inside the pump conduit box may be exposed (not covered with wire nut and/or electrical tape) that could cause a potential electrical shock hazard.
- Z-1194-2007 · Zimmer Inc. · posted Aug 23, 2007 · Terminated
The package actually contains a knee patellar implant.
- Z-1174-2007 · Dade Behring, Inc. · posted Aug 22, 2007 · Terminated
Sample ID and Patient results could be associated with the wrong patient
- Z-1178-2007 · Carmel Pharma, Inc. · posted Aug 22, 2007 · Terminated
Risk of Leakage: When the PhaSeal Protector and Injector are used with drug vials with thick rubber stoppers which have a concave upper surface and a flat bottom surface there is a potential for leakage. These rubber stoppers are made of a harder rubber…
- Z-1179-2007 · Carmel Pharma, Inc. · posted Aug 22, 2007 · Terminated
Risk of Leakage: When the PhaSeal Protector and Injector are used with drug vials with thick rubber stoppers which have a concave upper surface and a flat bottom surface there is a potential for leakage. These rubber stoppers are made of a harder rubber…
- Z-1180-2007 · Carmel Pharma, Inc. · posted Aug 22, 2007 · Terminated
Risk of Leakage: When the PhaSeal Protector and Injector are used with drug vials with thick rubber stoppers which have a concave upper surface and a flat bottom surface there is a potential for leakage. These rubber stoppers are made of a harder rubber…
- Z-1181-2007 · Carmel Pharma, Inc. · posted Aug 22, 2007 · Terminated
Risk of Leakage: When the PhaSeal Protector and Injector are used with drug vials with thick rubber stoppers which have a concave upper surface and a flat bottom surface there is a potential for leakage. These rubber stoppers are made of a harder rubber…
- Z-1185-2007 · Abbott Diagnostic International, Ltd. · posted Aug 22, 2007 · Terminated
Controls Out of Range/Specification .
- Z-1186-2007 · Abbott Diagnostic International, Ltd. · posted Aug 22, 2007 · Terminated
Controls Out of Range/Specification .
- Z-1187-2007 · Abbott Diagnostic International, Ltd. · posted Aug 22, 2007 · Terminated
Controls Out of Range/Specification.
- Z-1188-2007 · Abbott Diagnostic International, Ltd. · posted Aug 22, 2007 · Terminated
Controls Out of Range/Specification.
- Z-1189-2007 · bioMerieux, Inc. · posted Aug 22, 2007 · Terminated
Microbial Contamination: Bacillus sp. contamination was detected in inoculated bottles.
- Z-1191-2007 · Boston Scientific Corp · posted Aug 22, 2007 · Terminated
Product is mislabeled as hexapolar (6 electrodes), but is actually quadripolar (4 electrodes).
- Z-1170-2007 · Abbott Laboratories · posted Aug 18, 2007 · Terminated
Abnormal results may not be "flagged" appropriately because of a software anomaly. (Flags for the Hemoglobin (HGB), MCH and MCHC parameters when the upper assay paramter limit has been exceeded)
- Z-1171-2007 · Abbott Laboratories · posted Aug 18, 2007 · Terminated
Abnormal results may not be "flagged" appropriately because of a software anomaly. (Flags for the Hemoglobin (HGB), MCH and MCHC parameters when the upper assay paramter limit has been exceeded)
- Z-1173-2007 · Sendx Medical Inc · posted Aug 18, 2007 · Terminated
Error in the Ca12 calibration value for pCO2 recorded in the cal pack barcode for lot 17323. This error will result in falsely elevated pCO2 results at the high end of the measuring range.
- Z-1183-2007 · Arizant Healthcare, Inc · posted Aug 18, 2007 · Terminated
Incomplete seal on the product pouch; with the seal incomplete, the sterility of the product inside the pouch cannot be guaranteed.
- Z-1184-2007 · Arizant Healthcare, Inc · posted Aug 18, 2007 · Terminated
Incomplete seal on the product pouch; with the seal incomplete, the sterility of the product inside the pouch cannot be guaranteed.
- Z-1172-2007 · The Sisus Corporation · posted Aug 17, 2007 · Terminated
Poor welding may cause the device(s) to fail, which may result in the user, falling in the bathroom and/or a lack of assistance with bathing or toileting.
- Z-1175-2007 · Louisville Apl Diagnostics Inc · posted Aug 17, 2007 · Terminated
Mislabeing : Errors (control values) identified in the QC Fact Sheet for a specific lot of APhL HRP IgG and IgM test kits.
- Z-1176-2007 · Louisville Apl Diagnostics Inc · posted Aug 17, 2007 · Terminated
Mislabeling: Errors (control values) identified in the QC Fact Sheet for a specific lot of APhL HRP IgG and IgM test kits.
- Z-1177-2007 · Louisville Apl Diagnostics Inc · posted Aug 17, 2007 · Terminated
Mislabeling: Errors (control values) identified in the QC Fact Sheet for a specific lot of APhL HRP IgG and IgM test kits.
- Z-1165-2007 · Lifescan Inc · posted Aug 16, 2007 · Terminated
Lancet tip may not fully retract and cause needle stick and exposure to used lancets.
- Z-1166-2007 · ICU Medical, Inc. · posted Aug 16, 2007 · Terminated
The product contains a female luer which has been reported to crack in use allowing fluid to leak from the device.
- Z-1167-2007 · Ortho-Clinical Diagnostics · posted Aug 16, 2007 · Terminated
Software design. The firm received a customer complaint regarding a qualitative positive THC (Cannabinoids) result obtained from a THC quality control fluid that was known to be negative when using VITROS Chemistry Products THC Reagent. A second customer…
- Z-1169-2007 · Hamilton Co · posted Aug 16, 2007 · Terminated
Some product containers may be leaking.
- Z-1150-2007 · Zinnanti Surgical Design LLC · posted Aug 14, 2007 · Terminated
Bubble Leak Test Failure of sterility barrier, therefore sterility of the device may be compromised
- Z-1163-2007 · Sunrise Medical Inc · posted Aug 14, 2007 · Terminated
The wire harness connected to the display housing (Quickie IQ Enhanced Displays) may separate and cause sparks from a short circuit.
- Z-1131-2007 · Possis Medical, Inc · posted Aug 10, 2007 · Terminated
Mislabeling : Possis AngioJet XVG Catheter Thrombectomy Sets display incorrect information on the outer packaging box and also on the inner sterile tray. The labeling incorrectly states that the unit is indicated for use in coronary vessels. These units…
- Z-1072-2007 · Diagnostica Stago, Inc. · posted Aug 9, 2007 · Terminated
Specific lots of STA Liatest Free Protein S may result in low results in the assigned value ranges and sometimes outside the lower limit.
- Z-1073-2007 · Gyrus ACMI Corporation · posted Aug 9, 2007 · Terminated
Sterilization Instructions not adequate for sterilizing.
- ISOLOC Software Version 4.2, Part Number NT-NW-425-520. Image guided radiation treatment software. ↗Z-1155-2007 · Northwest Medical Physics Equipment Inc · posted Aug 9, 2007 · Terminated
When ISOLOC Version 4.2 unit is set to centimeter and the user clicks the Reenter button in the digitizer window, the coordinates of the markers and target in the anatomic imaging system erroneously displays values ten times greater than the correct values.
- Z-1156-2007 · Datascope Corporation · posted Aug 9, 2007 · Terminated
Datascope has experienced a higher than usual number of reports involving the Precision Bipolar Device. Reports include the locking or sticking of the buttons of the device which operate the jaws, particularly when a side load is placed on the shaft of…
- Z-1157-2007 · Datascope Corporation · posted Aug 9, 2007 · Terminated
Datascope has experienced a higher than usual number of reports involving the Precision Bipolar Device. Reports include the locking or sticking of the buttons of the device which operate the jaws, particularly when a side load is placed on the shaft of…
- Z-1158-2007 · Datascope Corporation · posted Aug 9, 2007 · Terminated
Datascope has experienced a higher than usual number of reports involving the Precision Bipolar Device. Reports include the locking or sticking of the buttons of the device which operate the jaws, particularly when a side load is placed on the shaft of…
- Z-1159-2007 · Boston Scientific Corporation · posted Aug 9, 2007 · Terminated
Labels on the carton from two batches/lots of Impulse Angiographic Catheters may indicate a different curve style than the device that is actually in the carton.
- Z-1160-2007 · Boston Scientific Corporation · posted Aug 9, 2007 · Terminated
Labels on the carton from two batches/lots of Impulse Angiographic Catheters may indicate a different curve style than the device that is actually in the carton.
- Z-1161-2007 · Boston Scientific Corporation · posted Aug 9, 2007 · Terminated
Boston Scientific NexStent Carotid Stent device failed to deploy when the outer catheter (proximal outer and distal sheath) did not pull back and expose the self-expanding stent.
- Z-1162-2007 · Cook Urological, Inc. · posted Aug 9, 2007 · Terminated
Lack of assurance of sterility, in that the product is labeled as sterile but the package may not have been sealed.
- Z-1141-2007 · Ross Products Division Abbott Laboratories · posted Aug 8, 2007 · Terminated
Continued use of the pump may cause the door pivot point on the back of the pump to crack or break. This will cause the pump to shut down and stop the initiation of enteral feeding.
- Z-1143-2007 · Kimberly-Clark Corporation · posted Aug 8, 2007 · Terminated
The tubes may kink during use which may impede or prevent ventilation.
- Z-1144-2007 · Kimberly-Clark Corporation · posted Aug 8, 2007 · Terminated
The tubes may kink during use which may impede or prevent ventilation.
- Z-1145-2007 · Northwest Medical Physics Equipment Inc · posted Aug 8, 2007 · Terminated
Isoloc version 6.5 and 4.5 software issued a false warning message regarding Gantry angles when set to "Anatomic Landmark" setting.
- Z-1146-2007 · Northwest Medical Physics Equipment Inc · posted Aug 8, 2007 · Terminated
This correction was for several software bugs which caused image format problems; incorrect ruler display; software crashes; failure to update pixel spacing; display of unattainable treatment table positions; failure to update gantry angles; wrong shifts…
- Z-1147-2007 · Northwest Medical Physics Equipment Inc · posted Aug 8, 2007 · Terminated
When the ISOLOC (Version 4.2) profile distance unit is set to "centimeter" and the user clicked the "back" button in the digitizer window, the marker and target coordinates in the localization window erroneously display values ten times greater than the…
- Z-1152-2007 · Northwest Medical Physics Equipment Inc · posted Aug 8, 2007 · Terminated
When ISOLOC version 6.0 and 4.2 distance unit is set to centimeter, the localization coordinates were rounded to the nearest millimeter which could affect positioning by 0.5 mm.
- Z-1153-2007 · Northwest Medical Physics Equipment Inc · posted Aug 8, 2007 · Terminated
When ISOLOC version 6.0 was used in the centimeter mode, the display in the couch moves window had a rounding error relative to the Portal Image Marker window of up to 0.5 mm.
- Z-1154-2007 · Northwest Medical Physics Equipment Inc · posted Aug 8, 2007 · Terminated
When ISOLOC version 6.0 software was used in the Anatomic Landmark mode, the couch moves display in the Couch Translator window was incorrect.
- Z-1127-2007 · Instrumentation Laboratory Co. · posted Aug 7, 2007 · Terminated
ACL TOP unit, when in emergency stop may release liquid during recovery sequence and contaminate sample tube.
- Z-1128-2007 · Philips Medical Systems · posted Aug 7, 2007 · Terminated
The ECG signal may become unusable to assess patient condition and need for therapy.
- Z-1129-2007 · Curlin Medical Llc · posted Aug 7, 2007 · Terminated
The Administration Sets may leak at the reservior bag.
- Z-1130-2007 · GE OEC Medical Systems, Inc · posted Aug 7, 2007 · Terminated
Cleaning probes used to unclog disposable aspirators may shed small particles of nylon material which may be transferred into the nasal cavity.
- Z-1132-2007 · General Electric Medical Systems Information Technology · posted Aug 7, 2007 · Terminated
GE Healthcare has identified conditions that could cause a potential loss of real-time monitoring with the CardioLab/Mac-Lab/ComboLab Electrophysiology and Hemodynamic Monitoring Systems. These issues are associated with an audio driver, and the use of…
- Z-1133-2007 · General Electric Medical Systems Information Technology · posted Aug 7, 2007 · Terminated
GE Healthcare has identified conditions that could cause a potential loss of real-time monitoring with the CardioLab/Mac-Lab/ComboLab Electrophysiology and Hemodynamic Monitoring Systems. These issues are associated with an audio driver, and the use of…
- Z-1134-2007 · General Electric Medical Systems Information Technology · posted Aug 7, 2007 · Terminated
GE Healthcare has identified conditions that could cause a potential loss of real-time monitoring with the CardioLab/Mac-Lab/ComboLab Electrophysiology and Hemodynamic Monitoring Systems. These issues are associated with an audio driver, and the use of…
- Z-1135-2007 · Encore Medical, Lp · posted Aug 7, 2007 · Terminated
Complaints received that device used to prepare femur to receive femoral implant would split during surgery.
- Z-1136-2007 · Encore Medical, Lp · posted Aug 7, 2007 · Terminated
Complaints received that device used to prepare femur to receive femoral implant would split during surgery.
- Z-1137-2007 · Encore Medical, Lp · posted Aug 7, 2007 · Terminated
Complaints received that device used to prepare femur to receive femoral implant would split during surgery.
- Z-1138-2007 · Encore Medical, Lp · posted Aug 7, 2007 · Terminated
Complaints received that device used to prepare femur to receive femoral implant would split during surgery.
- Z-1139-2007 · Encore Medical, Lp · posted Aug 7, 2007 · Terminated
Complaints received that device used to prepare femur to receive femoral implant would split during surgery.
- Z-1140-2007 · Encore Medical, Lp · posted Aug 7, 2007 · Terminated
Complaints received that device used to prepare femur to receive femoral implant would split during surgery.
- Z-1142-2007 · Ross Products Division Abbott Laboratories · posted Aug 7, 2007 · Terminated
The transducer adapter bracket on the pump could crack or break and potentially result in under delivery of the enteral product.
- Z-1149-2007 · Applied Composite Technology · posted Aug 7, 2007 · Terminated
Prosthetic foot device may loosen or separate during use; due to structural inconsistency that may cause a pyramid failure.
- Z-1151-2007 · Biomet, Inc. · posted Aug 7, 2007 · Terminated
The instrument was manufactured incorrectly and use could result in the instrument binding to the acetabular component and cause implant to not release following inpaction.
- Z-1148-2007 · Medtronic Emergency Response Systems, Inc. · posted Aug 4, 2007 · Terminated
Reduced Shock- the device may deliver 100 Joule (J) to a patient, which is less than the recommended factory minimum default setting of 200 J.
- Z-1078-2007 · Cardinal Health 303 Inc DBA Alaris Products · posted Aug 3, 2007 · Terminated
The sterility of the product may be compromised as the packaging used for the sterility barrier was not designed for the sterility process used by the firm.
- Z-1020-2007 · Cardinal Health 303 Inc DBA Alaris Products · posted Aug 2, 2007 · Terminated
It has been determined that with low probability, over-infusion may occur as a result of an open safety clamp fitment (a.k.a. Flo-Stop fitment) on the pumping segment, whether opened intentionally in the course of expected clinical practice, or as a result…
- Z-1021-2007 · Bausch & Lomb Inc · posted Aug 2, 2007 · Terminated
Reports have been received of stromal incursions after use of the product.
- Z-1022-2007 · Bausch & Lomb Inc · posted Aug 2, 2007 · Terminated
Reports have been received of stromal incursions after use of the product.
- Z-1105-2007 · Smith & Nephew, Inc Endoscopy Division · posted Aug 2, 2007 · Terminated
Build-up of static charge in Pneumatic Footswitch tubing may cause control unit to reset to default settings in the operating room during surgery.
- Z-1106-2007 · Roche Molecular Systems, Inc. · posted Aug 2, 2007 · Terminated
For select COBAS AMPLICOR Tests run on the COBAS AMPLICOR Analyzer in conjunction with AMPLILINK software, a discrepancy has been identified between the onboard working reagent stability information reported by AMPLILINK Software (versions 1.1, 1.3, 1.4…
- Z-1107-2007 · Roche Molecular Systems, Inc. · posted Aug 2, 2007 · Terminated
For select COBAS AMPLICOR Tests run on the COBAS AMPLICOR Analyzer in conjunction with AMPLILINK software, a discrepancy has been identified between the onboard working reagent stability information reported by AMPLILINK Software (versions 1.1, 1.3, 1.4…
Source: FDA Medical Device Recalls and FDA enforcement reports (recall class), via openFDA. Records are grouped by the date the FDA posted them. Methodology · Not medical advice.