Medical device recalls: March 2019
The FDA posted 14 medical device recall records in March 2019, from 8 recall events by 8 companies. 3 are Class I, the most serious category.
Each product in a recall gets its own record, so one recall event can cover several records. What recall classes mean.
Companies with the most recall events
- Getinge US Sales LLC · 1 event, 4 records
- Beckman Coulter Inc. · 1 event, 2 records
- CTL Medical Corporation · 1 event, 2 records
- Reckitt Benckiser LLC · 1 event, 2 records
- Cook Inc. · 1 event, 1 record, 1 Class I
- Maquet Cardiovascular Us Sales, Llc · 1 event, 1 record, 1 Class I
- Microbiologics Inc · 1 event, 1 record
- Rvo 2.0, Inc · 1 event, 1 record, 1 Class I
FDA root cause
- Under Investigation by firm · 4
- Other · 4
- Process control · 2
- Nonconforming Material/Component · 2
- Unknown/Undetermined by firm · 1
- Error in labeling · 1
Class I recalls (3)
The most serious: a reasonable probability that using the device will cause serious health problems or death.
- Z-0986-2019 · Maquet Cardiovascular Us Sales, Llc · posted Mar 28, 2019 · Terminated
Upon servicing the gearwheel in the Emergency Drive the gearwheel may have been re-assembled incorrectly, leading to the inadequate operation of the Emergency Drive.
- Z-0979-2019 · Cook Inc. · posted Mar 13, 2019 · Terminated
The products were manufactured without a back bevel on the needle tip. This could cause damage to the inside of the introducer during needle insertion.
- Z-0865-2019 · Rvo 2.0, Inc · posted Mar 5, 2019 · Terminated
During a post approval study the firm found there was an increased risk of corneal haze following the implantation of this device.
Class II recalls (11)
The device may cause temporary or medically reversible health problems, or the chance of serious harm is remote.
- The UniCel DxI 600 and 800 Access Immunoassay Systems, that are connected to an automation line. ↗Class IIZ-1077-2019 · Beckman Coulter Inc. · posted Mar 30, 2019 · Open, Classified
When racks are front-loaded onto the sample presentation unit while samples from the automation line are being processed, a scheduling error within the software can cause mishandling of samples during the creation of an aliquot and lead to incorrect…
- Z-1078-2019 · Beckman Coulter Inc. · posted Mar 30, 2019 · Open, Classified
When racks are front-loaded onto the sample presentation unit while samples from the automation line are being processed, a scheduling error within the software can cause mishandling of samples during the creation of an aliquot and lead to incorrect…
- Z-1030-2019 · CTL Medical Corporation · posted Mar 20, 2019 · Terminated
the anti-toggle ring of the hex driver may separate from the driver shaft. If this occurs during surgery, the anti-toggle ring can be pressed into the pedicle screw head and cause separation of the screw from the housing upon tightening. if the…
- Z-1031-2019 · CTL Medical Corporation · posted Mar 20, 2019 · Terminated
the anti-toggle ring of the hex driver may separate from the driver shaft. If this occurs during surgery, the anti-toggle ring can be pressed into the pedicle screw head and cause separation of the screw from the housing upon tightening. if the…
- Z-0993-2019 · Reckitt Benckiser LLC · posted Mar 9, 2019 · Terminated
Five batches of the product have failed the specification of 1.0kPa for Burst Pressure.
- Z-0994-2019 · Reckitt Benckiser LLC · posted Mar 9, 2019 · Terminated
Five batches of the product have failed the specification of 1.0kPa for Burst Pressure.
- Z-0982-2019 · Microbiologics Inc · posted Mar 7, 2019 · Terminated
Cepheid Xpert Respiratory Control Panel (Catalog #8199) has an reduced expiration date from 24 months to 13 months.
- Z-0987-2019 · Getinge US Sales LLC · posted Mar 7, 2019 · Terminated
The affected flat screen monitor holders might not be compliant with grounding requirements. As a consequence, there is a risk of mild to severe/fatal electric shock under certain conditions while using the flat screen monitor holder with voltage of 100-220V.
- Z-0988-2019 · Getinge US Sales LLC · posted Mar 7, 2019 · Terminated
The affected flat screen monitor holders might not be compliant with grounding requirements. As a consequence, there is a risk of mild to severe/fatal electric shock under certain conditions while using the flat screen monitor holder with voltage of 100-220V.
- Z-0989-2019 · Getinge US Sales LLC · posted Mar 7, 2019 · Terminated
The affected flat screen monitor holders might not be compliant with grounding requirements. As a consequence, there is a risk of mild to severe/fatal electric shock under certain conditions while using the flat screen monitor holder with voltage of 100-220V.
- Maquet XS Flat Screen Monitor Holder, SAT XS32 12 SPE, Configuration Part Number ARD2SAT00130A ↗Class IIZ-0990-2019 · Getinge US Sales LLC · posted Mar 7, 2019 · Terminated
The affected flat screen monitor holders might not be compliant with grounding requirements. As a consequence, there is a risk of mild to severe/fatal electric shock under certain conditions while using the flat screen monitor holder with voltage of 100-220V.
Source: FDA Medical Device Recalls and FDA enforcement reports (recall class), via openFDA. Records are grouped by the date the FDA posted them. Methodology · Not medical advice.