Operator Console for BrightSpeed Elite and BrightSpeed Elite SelectRecalls & reported problems

GE Hangwei Medical Systems Company Ltd. · Operator Console Upgrade Kit Medical Device for BSD Power and Lite · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
0
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

No MAUDE adverse event reports in our data reference this device identifier directly.

1 FDA recall record name this device's identifier, 1 still open.

9 other recalls cover devices cleared under the same FDA submission (K082816); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Recalls naming this device

  1. Nov 5, 2024Class IIOpen, Classified

    GE HealthCare has become aware of a potential issue on certain Discovery, Optima, Revolution series CT systems, and certain operator console upgrades that can result in rotated CT images. Particularly with helical, cine, and cardiac (if applicable) scan modes, after the first image of an exam, each subsequent image can be rotated by an increasing amount. The amount of progressive image rotation is dependent on the gantry speed and the duration of the scan. The final image in the exam can be rotated up to a maximum of ~56 degrees. The entire anatomy rotates as a whole by equal degrees, without distortion, and the anatomical positioning and z-axis of the images remains correct. Small degrees of image rotation might not be noticed. If image rotation is noticed and necessitates a rescan of the patient, the same image rotation will reoccur.

    Z-0614-2025 · Root cause: Component design/selection · Recall details · FDA record ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K082816. One submission often covers many models, so check the product and lot details in each record.

  • Z-2586-2018 · May 24, 2018 · Terminated
    Optima CT 540
  • Z-2872-2018 · Apr 27, 2018 · Terminated
    GE Healthcare Optima CT540. The systems are intended for head, whole body, cardiac and vascular X-ray Computed Tomography applications.Sold under the following product names: BE
  • Z-2873-2018 · Apr 27, 2018 · Terminated
    GE Healthcare Optima CT660. The systems are intended for head, whole body, cardiac and vascular X-ray Computed Tomography applications. Sold only outside the U.S. under the follow
  • Z-2188-2017 · May 19, 2017 · Terminated
    GE Healthcare BrightSpeed X-ray system
  • Z-2186-2017 · May 19, 2017 · Terminated
    GE Healthcare Optima CT540 X-ray system
  • Z-0840-2014 · Oct 9, 2013 · Terminated
    GE Optima CT520 and Optima CT540 Computed Tomography (CT) systems. Intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data t
  • Z-2214-2011 · Jan 19, 2011 · Terminated
    BrightSpeed Excel Select, BrightSpeed Edge Select ,BrightSpeed Elite Select and BrightSpeed Elite Computed Tomography X-ray systems with software version 09BW35.11 or 09HW30.4. Th
  • Z-0369-2011 · Sep 3, 2010 · Terminated
    GE BrightSpeed Excel/Edge/Elite Select / Elite CT Scanner System, models 2377708-560, 5377708-540, 5377708-560. Composed of a gantry, patient table, operator console, computer, an
  • Z-0368-2011 · Sep 3, 2010 · Terminated
    GE LightSpeed VCT Scanner System, models 5212920-300, 5212920-310, 5311595-10. Composed of a gantry, patient table, operator console, computer, and PDU and includes image acquisit

Other System, X-Ray, Tomography, Computed devices

All System, X-Ray, Tomography, Computed devices →