Skip to content

Shockwave IVL System with the Shockwave S4 Peripheral IVL Catheter S4IVL3040Recalls & reported problems

Shockwave Medical, Inc. · The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00195451000058), received between Sep 19, 2022 and Dec 2, 2022 — classified as 2 injuries.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Insufficient Device Problem Information1

Patient problems

  • Cardiogenic Shock1
  • Hemorrhage/Blood Loss/Bleeding1
  • Pain1
  • Post Operative Wound Infection1
  • Pseudoaneurysm1
  • Restenosis1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 2, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    POST BTK II STUDY USING A SHOCKWAVE PERIPHERAL LITHOTRIPSY CATHETER, THE PATIENT PRESENTED TO THE EMERGENCY DEPARTMENT (ED) DUE TO SEVERAL DAYS OF LEFT KNEE PAIN. THE STAFF TOOK X-RAYS AND WAS DISCHARGED TO HOME. THE PATIENT RETURNED TO THE ED AND UNDERWENT A COMPUTED TOMOGRAPHY ANGIOGRAPHY (CTA) TO THE CHEST, ABDOMEN, AND PELVIS. IT WAS FOUND THAT THERE WAS EXTRAVASATION OF THE LEFT EXTERNAL ILIAC ARTERY (EIA) PSEUDOANEURYSM. THE PATIENT WAS PROVIDED 2.25 LITERS OF INTRAVENOUS FLUIDS AND 3 UNITS OF PACKED RED BLOOD CELLS (PRBC) DUE TO BLOOD LOSS. THE PATIENT ALSO STARTED ON LEVOPHED (NOREPINEPHRINE BITARTRATE). AS OF THIS DATE (B)(6) 2022, THE PATIENT IS STILL IN THE HOSPITAL.

    Patient problems: Cardiogenic Shock; Hemorrhage/Blood Loss/Bleeding; Pain; Pseudoaneurysm

    MAUDE report 15911914 ↗
  • InjurySep 19, 2022Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information

    THIS REPORT IS BEING SUBMITTED BY SHOCKWAVE MEDICAL, INC. REGARDING THE PERIPHERAL S4 INTRAVASCULAR LITHOTRIPSY CATHETER (S4IVL) WHICH WAS USED IN A CLINICAL BTK II STUDY. IT WAS REPORTED THAT A PATIENT PRESENTED AT THE HOSPITAL POST PROCEDURE ON (B)(6) 2022. IT WAS FOUND THAT THERE WAS A LESION REVASCULARIZATION IN THE LEFT ANTERIOR TIBIAL ARTERY OF THE TREATED LEFT LEG. REPORTEDLY, THE ADVERSE EVENT HAS A PROBABLE RELATIONSHIP TO THE DEVICE, BUT IT HAS NO RELATIONSHIP TO THE PROCEDURE. THE REPORTED ADVERSE EVENT WAS RESOLVED ON (B)(6) 2022 WITH PERCUTANEOUS THERAPY AND WITH A CUTTING BALLOON.

    Patient problems: Post Operative Wound Infection; Restenosis

    MAUDE report 15451349 ↗

FDA clearance and classification

Cleared through Special 510(k) K191840 on Aug 7, 2019 (decision: Substantially Equivalent). Submitted by Shockwave Medical, Inc. as “Peripheral Intravascular Lithotripsy (IVL) Catheters, IVL Generator and Connector Cable Kit, IVL Connector Cable (Replacement)”. The FDA review took 29 days. FDA record ↗

The FDA regulates product code PPN (percutaneous catheter, ultrasound) under 21 CFR 870.1250 as a Class II device. 21 CFR 870.1250 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

FDA definition of this device type: Intended for ultrasound wave enhanced balloon dilatation of lesions, including calcified lesions, in the peripheral vasculature.

Common questions about the Shockwave IVL System with the Shockwave S4 Peripheral IVL Catheter S4IVL3040

Has the Shockwave IVL System with the Shockwave S4 Peripheral IVL Catheter S4IVL3040 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00195451000058), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Shockwave IVL System with the Shockwave S4 Peripheral IVL Catheter S4IVL3040?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between Sep 19, 2022 and Dec 2, 2022. In those reports, the most common patient problems are “Cardiogenic Shock” (1), “Hemorrhage/Blood Loss/Bleeding” (1) and “Pain” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Shockwave IVL System with the Shockwave S4 Peripheral IVL Catheter S4IVL3040?

None of the reports are classified as deaths, 2 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Shockwave IVL System with the Shockwave S4 Peripheral IVL Catheter S4IVL3040 FDA approved?

It was cleared through Special 510(k) K191840 on Aug 7, 2019. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the Shockwave IVL System with the Shockwave S4 Peripheral IVL Catheter S4IVL3040, and is it still sold?

The FDA's device database lists Shockwave Medical, Inc. as the company responsible for it (brand Shockwave IVL System with the Shockwave S4 Peripheral IVL Catheter, model S4IVL3040). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Percutaneous Catheter, Ultrasound devices

All Percutaneous Catheter, Ultrasound devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page