Alcon 8065752192Recalls & reported problems
Alcon Laboratories, Inc. · ACTIVE FMS W/ INTREPID* ULTRA SLEEVES, 0.9MM 30° KELMAN* Mini-Flared ABS* Tip · Class 2
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 8
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 00380657521920), received between Jul 13, 2022 and Apr 28, 2025 — classified as 2 injuries, 6 malfunctions.
The most frequently reported specific device problem is “Suction Failure” (4 reports).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Recalls naming this device
- Jun 28, 2023Open, Classified
Reports of patient injury during use in procedures due to potential for plastic debris from over-tightening with included plastic wrench.
Z-2407-2023 · Root cause: Process control · FDA record ↗
Most reported problems
Device problems
- Suction Failure4
- Adverse Event Without Identified Device or Use Problem1
- Defective Device1
- Device Alarm System1
- Fitting Problem1
- Inability to Irrigate1
- Material Twisted/Bent1
- Obstruction of Flow1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- Eye Burn2
- Corneal Edema1
- Insufficient Information1
- Rupture1
Recent adverse event reports
The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 28, 2025Obstruction of Flow; Suction Failure; Obstruction of Flow; Suction Failure
A HEALTHCARE PROFESSIONAL REPORTED THAT AN OPHTHALMIC OPERATING SYSTEM EXHIBITED WITH NO VACUUM BUILD UP AND INDICATING OCCLUSION DURING QUADRANT PHASE OF IOL IMPLANTATION SURGERY. SURGERY WAS COMPLETED AFTER REPLACING CASSETTE AND HANDPIECE. PATIENT IMPACT HAVE NOT BEEN PROVIDED. ADDITIONAL INFORMATION HAS BEEN REQUESTED BUT NONE RECEIVED TILL DATE.
Patient problems: Insufficient Information
MAUDE report 21916240 ↗MalfunctionMar 19, 2025Material Twisted/Bent; Material Twisted/Bent
A CUSTOMER REPORTED A FLUIDICS MANAGEMENT SYSTEM (FMS) PACK RECEIVED WITH A DAMAGED PHACOEMULSIFICATION TIP. THE PHACOEMULSIFICATION TIP WAS NOTED TO BE CURVED IN AN UNUSUAL WAY PRIOR TO PATIENT CONTACT DURING CALIBRATION OF CATARACT SURGERY (WITH INTRAOCULAR LENS IMPLANT). THE SURGERY WAS COMPLETED WITH ANOTHER FLUIDICS MANAGEMENT SYSTEM (FMS) PAK. THERE WAS NO PATIENT IMPACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21642856 ↗InjuryOct 10, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A CUSTOMER REPORTED THAT THE CARTRIDGE OR BAG WAS LEAKING ONTO THE FLOOR. THE CARTRIDGE WAS REPOSITIONED, WHICH APPARENTLY INTRODUCED AIR INTO THE LINE, RESULTING IN SUDDEN AIR FILL OF THE ANTERIOR CHAMBER AND POSTERIOR CAPSULAR RUPTURE DURING THE VITRECTOMY SURGERY. THE SURGERY WAS COMPLETED ON SAME DAY.
Patient problems: Rupture
MAUDE report 17902479 ↗MalfunctionAug 9, 2023Fitting Problem; Fitting Problem
A PHYSICIAN REPORTED THAT THE PHACO TIPS DID NOT THREAD CORRECTLY ONTO THE HANDPIECE BEFORE CATARACT SURGERY. THE SURGERY WAS COMPLETED AFTER REPLACING THE PRODUCT WITH NEW ONE. THERE WAS NO PATIENT HARM REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17485724 ↗MalfunctionJan 12, 2023Suction Failure; Suction Failure
AN OPHTHALMOLOGIST REPORTED THAT VACUUM STOPPED WORKING DURING THE EARLY QUADRANT REMOVAL. THE SURGEON STOPPED THE HANDPIECE (HP) AND FLUSHED ALSO TRIED VACUUMING WATER FROM A BOWL, BUT THE PROBLEM PERSISTED. THEREFORE, THE HP WAS CHANGED. THE VACUUM STILL PERSISTED; THEREFORE, THE CARTRIDGE (FMS) WAS CHANGED AND REPRIMED. FOLLOWING THIS, AN ERROR CODE WAS DISPLAYED AND HP WAS NO LONGER COULD BE PRIMED. THE HP WAS CHANGED FOR A THIRD TIME, BUT PROBLEM PERSISTED. A FULL RESET AND ALL THE EQUIPMENT WERE CHANGED; HOWEVER, VACUUM STILL REMAINED REDUCED FOR THE REMAINDER OF THE SURGERY. THE SURGEON FINISHED THE SURGERY WITHOUT ANY TROUBLE. HOWEVER, THE PATIENT HAD RETAINED THE LENS FRAGMENTS WHICH WERE LATER REMOVED IN A SURGERY PERFORMED LATER ON A DIFFERENT DAY. THERE WAS NO REPORT OF PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16146433 ↗MalfunctionSep 12, 2022Suction Failure; Suction Failure
A CUSTOMER REPORTED THERE WAS NO VACUUM FLOW AND STOPPED WORKING DURING THE CATARACT PROCEDURE. ALL SETTING AND SYSTEMS APPEARED TO BE WORKING FINE. THE FLUIDICS MANAGEMENT SYSTEM (FMS) PAK WAS REPLACED AND THE PROCEDURE WAS COMPLETED. THERE WAS NO REPORT OF PATIENT HARM. ADDITIONAL INFORMATION RECEIVED FROM THE COMPANY REPRESENTATIVE INDICATED THERE WAS NO ISSUE WITH THE IRRIGATION (FLUID GOING IN) BUT ONLY HAD NO ASPIRATION/FLOW OR VACUUM (FLUID COMING OUT).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15400987 ↗MalfunctionAug 5, 2022Signal Artifact/Noise; Defective Device; Suction Failure; Signal Artifact/Noise; Defective Device; Suction Failure
A CUSTOMER REPORTED A CASSETTE MALFUNCTION WHICH LED TO TEMPORAL WOUND BURN, THE HANDPIECE WAS UNABLE TO ASPIRATE UPON INITIATING THE PHACOEMULSIFICATION (PHACO) AND DELIVERY ULTRASOUND ENERGY DURING THE CATARACT PROCEDURE. WHITENING OF VISCOELASTIC WAS ALSO NOTED WITH OCCLUSION SOUNDING ON PHACO WHICH IMMEDIATELY CEASED. THE TEMPORAL WOUND BURN WAS NOTED AND COPIOUS IRRIGATION WITH BALANCE SALT SOLUTION (BSS) APPLIED. THE CASSETTE WAS REPLACED WITH A NEW ONE AND ONCE AGAIN PRIMED WITH THE SAME HANDPIECE AND NOW THE PROCEDURE WAS COMPLETED SUCCESSFULLY. ADDITIONAL INFORMATION WAS RECEIVED CONFIRMING WOUND BURN AS CORNEAL BURN.
Patient problems: Eye Burn
MAUDE report 15174069 ↗InjuryJul 13, 2022Device Alarm System; Inability to Irrigate; Device Alarm System; Inability to Irrigate
A CUSTOMER REPORTED INADEQUATE FLUID WAS IRRIGATING THE EYE AND THE PATIENT SUFFERED A WOUND BURN. THE PROCEDURE WAS COMPLETED AFTER THE PRODUCT WAS REPLACED. THE PATIENT REQUIRED SUTURING OF THE WOUND. THE SAMPLE IS NOT AVAILABLE FOR RETURN AS IT WAS DISCARDED. ADDITIONAL INFORMATION RECEIVED FROM THE COMPANY REPRESENTATIVE WHO INDICATED OCCLUSION TONE WAS HEARD DURING THE PROCEDURE. THE CORNEAL BURN RESULTED IN MILD GAPING AT END OF PROCEDURE BUT NO LEAK WAS OBSERVED WITH WOUND HYDRATION. THE PATIENT WAS SUTURED WITH ONE NYLON 10/0 FOR SAFETY. THE INJURY RESULTED IN POSTOPERATIVE ASTIGMATISM WHICH VALUED TO BE D1 6/12 (UNAIDED) AND FURTHER REVIEW FOR ASSESSING ASTIGMATISM WAS PLANNED IN A WEEK. THE BURN RESULTED IN CORNEAL OPACITY WHICH WAS CLEARED SIGNIFICANTLY AFTER THE EPITHELIUM WAS CLEARED OFF. THE PATIENT WAS STABLE ON DAY-1 POST OPERATION. ADDITIONAL INFORMATION RECEIVED FROM THE COMPANY REPRESENTATIVE WHO INDICATED THE PATIENT'S CURRENT CONDITION IS IMPROVING.
Patient problems: Corneal Edema; Eye Burn
MAUDE report 14999483 ↗
Other Unit, phacofragmentation devices
- Centurion 8065751763Alcon Laboratories, Inc. · Unit, phacofragmentation728 reports
- Centurion 8065753057Alcon Laboratories, Inc. · Unit, phacofragmentation639 reports
- CENTURION® 8065752914Alcon Laboratories, Inc. · Unit, phacofragmentation571 reports
- Constellation, Ultravit, 25+, TotalPlus, EdgePlus 8065751617Alcon Laboratories, Inc. · Unit, phacofragmentation2 recalls398 reports
- Alcon 8065752201Alcon Laboratories, Inc. · Unit, phacofragmentation1 recall386 reports
- Alcon 8065752200Alcon Laboratories, Inc. · Unit, phacofragmentation1 recall366 reports
- Constellation, Ultravit, 25+, TotalPlus, EdgePlus 8065751767Alcon Laboratories, Inc. · Unit, phacofragmentation2 recalls302 reports
- Constellation, ULTRAVIT, Engauge, 25+ 8065752415Alcon Laboratories, Inc. · Unit, phacofragmentation369 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.