Alinity 07P6220Recalls & reported problems
Abbott Ireland Diagnostics · Alinity i CEA Reagent Kit 200 Tests · Class 2
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00380740130855), received between Oct 27, 2022 and Jun 3, 2024 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Incorrect, Inadequate or Imprecise Result or Readings4
- Low Test Results1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 3, 2024Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
THE CUSTOMER OBSERVED DISCREPANT ALINITY I CEA RESULTS GENERATED FOR A PATIENT SAMPLE. THE FOLLOWING DATA WAS PROVIDED: PATIENT 1 (B)(6) 2023 RESULT WITH OLD LOT 49146FN00 = 2.0, (B)(6) 2023 RESULT WITH NEW LOT 50043FN00 = 3.1. ADDITIONALLY, THE CUSTOMER ALSO NOTED A SHIFT UP IN QUALITY CONTROLS. NO IMPACT TO PATIENT MANAGEMENT WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19455274 ↗MalfunctionJun 3, 2024Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
THE CUSTOMER OBSERVED DISCREPANT ALINITY I CEA RESULTS GENERATED FOR A PATIENT SAMPLE. THE FOLLOWING DATA WAS PROVIDED: PATIENT 1: ON (B)(6) 2023: RESULT WITH OLD LOT 49146FN00 = 2.0, ON (B)(6) 2023 RESULT WITH NEW LOT 50043FN00 = 3.1. ADDITIONALLY, THE CUSTOMER ALSO NOTED A SHIFT UP IN QUALITY CONTROLS. NO IMPACT TO PATIENT MANAGEMENT WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19454372 ↗MalfunctionNov 15, 2023Low Test Results; Low Test Results
THE CUSTOMER REPORTED A FALSELY DEPRESSED ALINITY I CEA RESULT FOR A PATIENT SAMPLE. IT IS UNKNOWN IF THE PATIENT HAS BEEN DIAGNOSED WITH CANCER. THE FOLLOWING DATA WAS PROVIDED: SAMPLE ID (B)(6): TESTED WITH ANALYZER AI21440 = < 1.73 NG/ML. SAMPLE ID (B)(6): RETESTED TESTED WITH ANALYZER AI24617 = 9.86 NG/ML. SAMPLE ID (B)(6): RETESTED WITH ANALYZER AI21440 = 9.62 NG/ML. THERE WAS NO IMPACT TO PATIENT MANAGEMENT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18145515 ↗MalfunctionOct 27, 2022Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
THE CUSTOMER OBSERVED DISCREPANT ALINITY I CEA RESULTS FOR A 77-YEAR-OLD FEMALE PATIENT. THE FOLLOWING DATA WAS PROVIDED: JULY RESULT (LOT 36540FN00) = 120.4 NG/ML, AUGUST RESULT (LOT 36543FN00) = 25.58 NG/ML, SEPTEMBER RESULT (LOT 39407FN00) = 79.6 NG/ML, OCTOBER RESULT (LOT 39407FN00) = 22.9 NG/ML. NO IMPACT TO PATIENT MANAGEMENT WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15687189 ↗MalfunctionOct 27, 2022Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
THE CUSTOMER OBSERVED DISCREPANT ALINITY I CEA RESULTS FOR A 77-YEAR-OLD FEMALE PATIENT. THE FOLLOWING DATA WAS PROVIDED: JULY RESULT (LOT 36540FN00) = 120.4 NG/ML, AUGUST RESULT (LOT 36543FN00) = 25.58 NG/ML, SEPTEMBER RESULT (LOT 39407FN00) = 79.6 NG/ML, OCTOBER RESULT (LOT 39407FN00) = 22.9 NG/ML. NO IMPACT TO PATIENT MANAGEMENT WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15687188 ↗
Other SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN devices
- ADVIA Centaur® CEA 10309977Siemens Healthcare Diagnostics Inc. · SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN14 reports
- ARCHITECT 07K68-27Abbott Ireland Diagnostics · SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN13 reports
- Elecsys CEA 07027079190Roche Diagnostics GmbH · SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN13 reports
- Atellica IM CEA 10995523Siemens Healthcare Diagnostics Inc. · SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN11 reports
- ADVIA Centaur® CEA 10309978Siemens Healthcare Diagnostics Inc. · SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN10 reports
- IMMULITE® 2000 Systems CEA 10380995Siemens Healthcare Diagnostics Products Ltd · SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN9 reports
- ARCHITECT 07K68-35Abbott Ireland Diagnostics · SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN8 reports
- Elecsys Anti-CCP 07251670190Roche Diagnostics GmbH · SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN8 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.