Hemagard HGK0008-70Recalls & reported problems
Intervascular Sas · Hemagard Knitted Straight Collagen Coated Vascular Graft · Class 2 · Implant
All models of Hemagard (28)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00384401014157), received between Aug 3, 2016 and Sep 27, 2016 — classified as 3 injuries.
The most frequently reported specific device problem is “Manufacturing, Packaging or Shipping Problem” (3 reports).
2 other recalls cover devices cleared under the same FDA submission (K964625); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Manufacturing, Packaging or Shipping Problem3
Patient problems
- Blood Loss3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjurySep 27, 2016Manufacturing, Packaging or Shipping Problem; Manufacturing, Packaging or Shipping Problem
DURING AN ILIOFEMORAL BYPASS PROCEDURE PERFORMED ON (B)(6) 2016, THERE WAS A LOT OF BLEEDING THROUGH THE GRAFT WALLS (MORE THAN "BLUSH") WHEN THE CLAMP WAS REMOVED. THE SURGEON HAD TO MANUALLY COAGULATE THE GRAFT WITH THE PATIENT BLOOD TO CONTROL THE BLEEDING, AND WORKED THE CLAMP OPEN AND CLOSED TO HELP TO COAGULATE AS WELL. THE GRAFT REMAINED IMPLANTED AND THE PATIENT WAS REPORTED AS BEING FINE.
Patient problems: Blood Loss
MAUDE report 5979327 ↗InjuryAug 4, 2016Manufacturing, Packaging or Shipping Problem; Manufacturing, Packaging or Shipping Problem
DURING A REDO AORTIC VALVE REPLACEMENT (AVR) PROCEDURE PERFORMED ON (B)(6) 2016, THE GRAFT WAS USED AS A CONDUIT FOR AXILLARY ARTERY CANNULATION. WHEN THE CLAMP WAS REMOVED, THERE WAS A LOT OF OOZING FROM THE GRAFT AND THE GRAFT HAD TO BE WRAPPED WITH A HEMOSTATIC AGENT. THE CASE WAS COMPLETED. NO ADVERSE OUTCOME FOR THE PATIENT WAS REPORTED. NO ADDITIONAL INFORMATION ON THE PRODUCT SERIAL NUMBER COULD BE OBTAINED AT THE DATE OF THIS REPORT.
Patient problems: Blood Loss
MAUDE report 5846118 ↗InjuryAug 3, 2016Manufacturing, Packaging or Shipping Problem; Manufacturing, Packaging or Shipping Problem
DURING A FEMORO-FEMORAL BYPASS PROCEDURE PERFORMED ON (B)(6) 2016, THE PATIENT WAS ON EXTRACORPOREAL MEMBRANE OXYGENATION WITH AN INITIAL CANNULATION AT THE FEMORAL ARTERY LEVEL AND WAS REPORTED TO BE VERY SICK. THE SURGEON WANTED TO MOVE THE CANNULATION TO THE AXILLARY ARTERY AND HE USED FOR THAT THE INVOLVED HEMAGARD GRAFT. THE GRAFT WAS REPORTED TO LEAK A LOT AND THE BLEEDING COULD NOT BE CONTAINED. SO THE GRAFT COULD NOT BE LEFT IN PLACE AND THE CANNULATION WAS MOVED TO ITS INITIAL LOCALISATION. THE PROCEDURE WAS THEN COMPLETED AND THE GRAFT WAS DISCARDED. NO ADVERSE OUTCOME FOR THE PATIENT WAS REPORTED AFTER THE SURGERY. IT WAS AFTERWARDS REPORTED THAT THE PATIENT DECEASED AT A LATER DATE DUE TO OTHER CAUSES UNRELATED TO THIS INCIDENT.
Patient problems: Blood Loss
MAUDE report 5842775 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K964625. One submission often covers many models, so check the product and lot details in each record.
- Z-1427-2010 · Dec 9, 2009 · TerminatedInterGard Knitted Collagen Coated Vascular prostheses, Catalog number: IGK1206. InterVascular SAS, France. Indicated for surgical repair, bypass or replacement of arteries in th
- Z-1439-2010 · Dec 9, 2009 · TerminatedInterGard Knitted Collagen Coated Vascular prostheses marketed under 510(k) # K964625; InterGard Woven Collagen Coated Vascular prostheses marketed under 510(k} #K970843 and K9842
Other Prosthesis, Vascular Graft, Of 6mm And Greater Diameter devices
- Cardioroot HEWROOT0030Intervascular Sas · Prosthesis, Vascular Graft, Of 6mm And Greater Diameter1 recall2 deaths13 reports
- FLIXENE SLIDER GDS 25058Atrium Medical Corporation · PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER1 recall13 reports
- ADVANTA SLIDER GDS 22114Atrium Medical Corporation · PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER1 recall11 reports
- Cardioroot HEWROOT0032Intervascular Sas · Prosthesis, Vascular Graft, Of 6mm And Greater Diameter1 recall2 deaths10 reports
- FLIXENE SLIDER GDS 25129Atrium Medical Corporation · PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER1 recall9 reports
- ADVANTA SLIDER GDS 22222Atrium Medical Corporation · PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER1 recall8 reports
- FLIXENE SLIDER GDS 25137Atrium Medical Corporation · PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER1 recall8 reports
- FLIXENE SLIDER GDS 25138Atrium Medical Corporation · PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER1 recall7 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.