Skip to content

Hemagard HGKUT0008-20Recalls & reported problems

Intervascular Sas · Hemagard Knitted Ultrathin Straight Collagen Coated Vascular Graft · Class 2 · Implant

All models of Hemagard (28)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00384401014751), received between Jun 14, 2016 and Jun 14, 2016 — classified as 1 injury.

The most frequently reported specific device problem is “Manufacturing, Packaging or Shipping Problem” (1 report).

1 other recall cover devices cleared under the same FDA submission (K983819); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Manufacturing, Packaging or Shipping Problem1

Patient problems

  • Blood Loss1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 14, 2016Manufacturing, Packaging or Shipping Problem; Manufacturing, Packaging or Shipping Problem

    DURING AN AORTIC DISSECTION PERFORMED ON (B)(6) 2016, THE GRAFT WAS USED FOR AXILLARY CANNULATION. IT WAS REPORTED THAT BLOOD LEAKING OCCURED AT SEVERAL PARTS OF THE GRAFT. NO ADVERSE OUTCOME FOR THE PATIENT WAS REPORTED.

    Patient problems: Blood Loss

    MAUDE report 5722730 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K983819. One submission often covers many models, so check the product and lot details in each record.

  • Z-0638-04 · Dec 30, 2003 · Terminated
    HemaCarotid Patch, Ultrathin, Collagen Coated Knitted Polyester Vascular Patch. Product Catalog Numbers: HEK06/75CPUT; HEK08/75CPUT; HEK14/75CPUT; HEK08/120CPUT; HEK10/75CPUT; H

Other Prosthesis, Vascular Graft, Of 6mm And Greater Diameter devices

All Prosthesis, Vascular Graft, Of 6mm And Greater Diameter devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page