Adapta™ ADDR01 (UDI 00613994222046)Recalls & reported problems

Medtronic, Inc. · IPG, ADDR01, ADAPTA, DR, IS-1, US · Class 3 · Implant

All models of Adapta (27)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Quick summary

This Medtronic Adapta pacemaker has 1,799 adverse event reports on record, including 39 deaths and 1,043 injuries. Many reports describe pacing problems, batteries running down early, and the device not being checked by clinicians, with some patients reporting slow heart rates and fainting. Reports fell to 43 in the last 12 months, from 87 in the year before. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
1,800
Deaths reported
39
Injuries reported
1,044
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1,800 adverse event reports that list this exact device (DI 00613994222046), received between Dec 10, 2014 and Sep 28, 2026 — classified as 39 deaths, 1,044 injuries, 717 malfunctions.

The most frequently reported specific device problem is “Pacing Problem” (295 reports).

16 other recalls cover devices cleared under the same FDA submission (P980035); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 12 reportsJan 2024: 12 reportsFeb 2024: 14 reportsMar 2024: 14 reportsApr 2024: 12 reportsMay 2024: 10 reportsJun 2024: 6 reportsJul 2024: 15 reportsAug 2024: 8 reportsSep 2024: 11 reportsOct 2024: 10 reportsNov 2024: 13 reportsDec 2024: 4 reportsJan 2025: 8 reportsFeb 2025: 11 reportsMar 2025: 8 reportsApr 2025: 4 reportsMay 2025: 5 reportsJun 2025: 6 reportsJul 2025: 9 reportsAug 2025: 8 reportsSep 2025: 9 reportsOct 2025: 2 reportsNov 2025: 10 reportsDec 2025: 3 reportsJan 2026: 7 reportsFeb 2026: 3 reportsMar 2026: 6 reportsApr 2026: 5 reportsMay 2026: 4 reportsJun 2026: 1 reportsJul 2026: 1 reportsAug 2026: 1 reportsSep 2026: 3 reportsOct 2026: 0 reportsNov 2026: 0 reports20242025202615
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem374
  • Pacing Problem295
  • Premature Discharge of Battery256
  • Appropriate Device Problem Term/Code Not Available249
  • Failure to Interrogate193
  • Battery Problem103
  • Communication or Transmission Problem87
  • Unable to Obtain Readings57

Patient problems

  • No Clinical Signs, Symptoms or Conditions549
  • No Known Impact Or Consequence To Patient337
  • Unspecified Infection219
  • Bradycardia143
  • No Consequences Or Impact To Patient72
  • Syncope/Fainting66
  • Dizziness63
  • Dyspnea50

Recent adverse event reports

The 25 most recent of 1,800 reports, in the reporter's own words as published by the FDA.

  • InjurySep 28, 2026Appropriate Device Problem Term/Code Not Available

    It was reported that the patient experienced a syncopal episode. The Implantable Pulse Generator (IPG) remains in use. No further patient complications have been reported as a result of this event.

    Patient problems: Syncope/Fainting

    MAUDE report 50912134 ↗
  • InjurySep 9, 2026Premature Discharge of Battery; Pacing Problem

    It was reported that the patient experienced bradycardia, pre-syncope and shortness of breath. It was further reported that the Implantable Pulse Generator (IPG) exhibited premature battery depletion and a pacing problem. It was further noted that the Right Ventricular (RV) lead exhibited high impedance, polarity switch and loss of capture. The IPG was explanted and the RV lead was capped. No patient complications have been reported as a result of this event.

    Patient problems: Bradycardia; Dyspnea; Presyncope

    MAUDE report 50688440 ↗
  • MalfunctionSep 7, 2026Premature Discharge of Battery

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50647327 ↗
  • MalfunctionAug 18, 2026Failure to Interrogate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50296471 ↗
  • InjuryJul 30, 2026Appropriate Device Problem Term/Code Not Available

    It was reported that the patient was found unresponsive on the floor. The patient's wife stated she was told the pacemaker just died, it just stopped working.  The Implantable Pulse Generator (IPG) was explanted and replaced due to normal Elective Replacement Indicator (ERI). No further patient complications have been reported as a result of this event.

    Patient problems: Loss of consciousness

    MAUDE report 50081788 ↗
  • MalfunctionJun 10, 2026Failure to Interrogate

    IT WAS REPORTED THAT THE IMPLANTABLE PULSE GENERATOR (IPG) COULD NOT BE INTERROGATED. TROUBLESHOOTING STEPS WERE INSUFFICIENT TO RESOLVE THE ISSUE. THE IPG REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25454854 ↗
  • MalfunctionMay 22, 2026Reset Problem

    IT WAS REPORTED THAT THERE WAS AN ELECTRICAL RESET, SINGLE CHAMBER FIXED RATE (VVI) SIXTY FIVE (65) BEATS PER MINUTE (BPM). THE DEVICE WAS EXPLANTED AND REPLACED DUE NORMAL ELECTIVE REPLACEMENT INDICATOR (ERI)- RECOMMENDED REPLACEMENT TIME (RRT) WAS TRIGGERED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25253902 ↗
  • MalfunctionMay 18, 2026Pacing Problem

    IT WAS REPORTED THAT THE PATIENT IS EXPERIENCING A HEART RATE IN THE THIRTIES AND FORTIES. THE IMPLANTABLE PULSE GENERATOR (IPG) REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Bradycardia

    MAUDE report 25199383 ↗
  • MalfunctionMay 12, 2026Failure to Interrogate

    IT WAS REPORTED THAT THEY WERE UNABLE TO INTERROGATE THE DEVICE. THE DEVICE REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25149470 ↗
  • MalfunctionMay 5, 2026Failure to Interrogate

    IT WAS REPORTED THAT THE MONITOR WAS UNABLE TO CATCH TELEMETRY FROM THE DEVICE DESPITE TROUBLESHOOTING, AND A ¿READER POSITION NO TELEMETRY¿ ISSUE WAS NOTED. NO TELEMETRY WAS NOTED ON THE IMPLANTABLE PULSE GENERATOR (IPG). THE PATIENT WAS REFERRED TO A CLINIC. THE IPG REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25078970 ↗
  • MalfunctionApr 21, 2026Pacing Problem; Reset Problem

    IT WAS REPORTED THAT THE PATIENT EXPERIENCED BRADYCARDIA AND THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED A LOSS OF CAPTURE AND PACING INHIBITION. IT WAS FURTHER REPORTED THAT THE IMPLANTABLE PULSE GENERATOR (IPG) EXHIBITED PACING BELOW THE LOWER RATE. THE RV LEAD REMAINS IN USE. THE IPG WAS EXPLANTED AND REPLACED DUE TO NORMAL ELECTIVE REPLACEMENT INDICATOR (ERI). NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions; Non specific EKG/ECG Changes

    MAUDE report 24940127 ↗
  • InjuryApr 14, 2026Premature Discharge of Battery

    IT WAS REPORTED THAT THE IMPLANTABLE PULSE GENERATOR (IPG) CAPTURE MANAGEMENT UNEXPECTEDLY WENT TO HIGH PACING OUTPUTS WHICH DEPLETED THE BATTERY EXCESSIVELY. THE IPG WAS EXPLANTED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24869325 ↗
  • InjuryApr 13, 2026Insufficient Device Problem Information

    IT WAS REPORTED BY THE PATIENT THAT THEY EXPERIENCED "A VIBRATION IN MY CHEST" AND THAT THE BATTERY WAS FAILING IN THE IMPLANTABLE PULSE GENERATOR (IPG). THE IPG WAS EXPLANTED AS WAS REPLACED. N OFURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 24854978 ↗
  • InjuryApr 9, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT EXPERIENCED A METHICILLIN-RESISTANT STAPHYLOCOCCUS AUREUS (MRSA) INFECTION WITH VEGETATION NOTED ON THE RIGHT VENTRICULAR (RV) LEAD. IT WAS ALSO NOTED THAT THE RV LEAD EXHIBITED A CONFIRMED FRACTURE, AN UNDEFINED OUT OF RANGE SPIKE IN IMPEDANCE, AND NO CAPTURE. THE IMPLANTABLE PULSE GENERATOR (IPG) SYSTEM WAS EXPLANTED AND REPLACED WITH A LEADLESS IPG. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Drug Resistant Bacterial Infection

    MAUDE report 24831016 ↗
  • MalfunctionApr 7, 2026Migration or Expulsion of Device

    THE PATIENT REPORTED THAT WITH THEIR FIRST PACEMAKER (PM), SHORTLY AFTER IMPLANT THEY WENT THROUGH A COURTHOUSE SCANNER AND AFTERWARDS THEY BEGAN TO FEEL UNWELL. THE PATIENT WAS TAKEN TO A NEARBY FIRE STATION WHERE THEY WERE RESUSCITATED AND THEN BROUGHT TO HOSPITAL. ONCE AT THE HOSPITAL PATIENT SAID THEIR DEVICE WAS CHECKED AND THEY WERE TOLD "SOMETHING TURNED OFF" THE PM. THE DEVICE WAS REPROGRAMMED IT AND IT THEN WORKED AS INTENDED. THE PATIENT REPORTED THAT THEIR CURRENT DEVICE HAS DROPPED DOWN A BIT FROM IT'S PLACEMENT. THE DEVICE REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24800242 ↗
  • InjuryMar 31, 2026Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT THE PATIENT STATED THEIR OLD IMPLANTABLE PULSE GENERATOR (IPG) WAS "DEFECTIVE." THE IPG WAS EXPLANTED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24740261 ↗
  • InjuryMar 26, 2026Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED BY A PATIENT REPRESENTATIVE THAT THE PATIENTS IMPLANTABLE PULSE GENERATOR (IPG) WAS "BAD". THE IPG WAS REMOVED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24699314 ↗
  • MalfunctionMar 25, 2026Battery Problem

    IT WAS REPORTED THAT  BY THE PATIENT THAT THEY "NEED AN MRI BUT NO ONE WILL DO IT. I NEED TO GET THIS PACEMAKER TAKEN OUT , THE BATTERY IS DEAD" THE IMPLANTABLE PULSE GENERATOR (IPG) REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24685368 ↗
  • InjuryMar 5, 2026Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT THE IMPLANTABLE PULSE GENERATOR (IPG) WAS NOT WORKING. THE IPG WAS REMOVED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Dyspnea; No Clinical Signs, Symptoms or Conditions; Palpitations

    MAUDE report 24518975 ↗
  • MalfunctionMar 4, 2026Failure to Interrogate

    IT WAS REPORTED THAT THEY CANNOT INTERROGATE THE DEVICE USING THE REMOTE MONITORING MOBILE APPLICATION. TECHNICAL SUPPORT CONFIRMED USING THE CORRECT APPLICATION. CALLER STATED THEY HAD PUT THE READER OVER THE DEVICE AND NO DEVICE SERIAL NUMBER. THEY HAD STATED THE GREEN BAR STARTED GOING ACROSS AND STOPPED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24506165 ↗
  • InjuryMar 3, 2026Battery Problem; Reset Problem

    IT WAS REPORTED THAT A FULL ELECTRICAL RESET OCCURRED. THE IMPLANTABLE PULSE GENERATOR (IPG) WAS EXPLANTED FOUR DAYS LATER DUE TO ELECTIVE REPLACEMENT INDICATOR (ERI) - RECOMMENDED REPLACEMENT TIME (RRT) WAS TRIGGERED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Dyspnea; Fatigue; No Clinical Signs, Symptoms or Conditions

    MAUDE report 24493460 ↗
  • MalfunctionFeb 26, 2026Pacing Problem

    IT WAS REPORTED THAT THE REMOTE MONITORING MOBILE DISPLAYED NO DEVICE FOUND MESSAGE WHEN ATTEMPTED TO INTERROGATE THE PATIENT DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24454678 ↗
  • InjuryFeb 13, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS FURTHER REPORTED THAT THE EVENT WAS NOT RELATED TO THE IPG SYSTEM.

    Patient problems: Cardiac Arrest

    MAUDE report 24330421 ↗
  • InjuryFeb 6, 2026Premature Discharge of Battery

    IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED HIGH THRESHOLDS RESULTING IN PREMATURE DEPLETION OF THE IMPLANTABLE PULSE GENERATOR (IPG). IT CAN BE NOTED THAT THE DEVICE WAS DETECTING FALSE THRESHOLDS RESULTING IN CAPTURE MANAGEMENT INCREASING OUTPUTS. THE DEVICE WAS EXPLANTED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24277927 ↗
  • MalfunctionJan 30, 2026Communication or Transmission Problem

    IT WAS FURTHER REPORTED THAT THE IPG EXHIBITED NORMAL DEVICE FUNCTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24220958 ↗

FDA clearance and classification

Approved through premarket approval (PMA) P980035 on Jan 29, 1999. Submitted by Medtronic, Inc. as “Medtronic Kappa 700/600 Series Pulse Generators And Model 9953 Software”. The FDA review took 157 days. The FDA has since approved 824 supplements (changes to the device or its labeling), most recently on Nov 11, 2026. FDA record ↗

Devices of this type need premarket approval (PMA), the FDA's most demanding review, usually with clinical data.

The FDA lists this type of device as life-sustaining or life-supporting.

Recalls under the same FDA submission

These recalls involve devices cleared under P980035. One submission often covers many models, so check the product and lot details in each record.

  • Z-2128-2025 · Jun 17, 2025 · Open, Classified
    Medtronic SmartLink software loaded on CareLink SmartSync Device Manager, Model Number 24967A with the following software components: 1. Azure Astra application, Software Model N
  • Z-2127-2025 · Jun 17, 2025 · Open, Classified
    Medtronic SmartLink Software loaded on SmartSync Patient Connector, Model Number 24967 with the following software components: 1. Azure Astra application, Software Model Number D
  • Z-1924-2025 · Apr 29, 2025 · Open, Classified
    Azure S DR MRI SureScan, Product number W3DR01
  • Z-2510-2020 · Jun 4, 2020 · Open, Classified
    Azure S SR MRI, Model Number W3SR01
  • Z-2507-2020 · Jun 4, 2020 · Open, Classified
    Azure XT DR MRI, Model Numbers: a) W1DR01 and b) W2DR01
  • Z-2508-2020 · Jun 4, 2020 · Open, Classified
    Azure S DR MRI, Model Number W3DR01
  • Z-2509-2020 · Jun 4, 2020 · Open, Classified
    Azure XT SR MRI, Model Numbers: a) W1SR01 and b) W2SR01
  • Z-0810-2019 · Jan 17, 2019 · Open, Classified
    Medtronic implantable pulse generator: Sphera DR MRI SureScan, Dual chamber rate responsive pacemaker (DDDR): (a) Model Number SPDR01 (b) Model Number SPDRL1
  • Z-0806-2019 · Jan 17, 2019 · Open, Classified
    Medtronic implantable pulse generator: ADAPTA, Dual chamber pacemaker (DDD): (a) Model Number ADD01 (b) Model Number ADDR01 (c) Model Number ADDR03 (d) Model Number ADDR06 (e) Mo
  • Z-0807-2019 · Jan 17, 2019 · Open, Classified
    Medtronic implantable pulse generator: ATTESTA L DR MRI SureScan, Dual chamber rate responsive pacemaker (DDDR): (a) Model Number ATDR01 (b) Model Number ATDRL1 (c) Model Number
  • Z-0811-2019 · Jan 17, 2019 · Open, Classified
    Medtronic implantable pulse generator: Versa, Dual chamber rate responsive pacemaker (DDDR), Model Number VEDR01
  • Z-0809-2019 · Jan 17, 2019 · Open, Classified
    Medtronic implantable pulse generator: SENSIA, Dual chamber pacemaker (DDD): (a) Model Number SED01 (b) Model Number SEDR01 (c) Model Number SEDRL1
  • Z-0808-2019 · Jan 17, 2019 · Open, Classified
    Medtronic implantable pulse generator: RELIA, Dual chamber pacemaker (VDD): (a) Model Number RED01 (b) Model Number REDR01 (c) Model Number REVDD01
  • Z-2120-2011 · Apr 4, 2011 · Terminated
    Medtronic, Kappa 600 KDR600,KDR601,KDR603,KDR606,KDR651,KDR653 The devices are implantable pulse generators (IPG) used to detect bradycardia events and provide pacing support. Wit
  • Z-1440-2010 · Feb 11, 2010 · Terminated
    Medtronic EnRhythm, P1501DR, Dual Chamber Rate Responsive Pacemaker with RapidRead Telemetry. The EnRhythm pacing system is an implantable medical device that monitors, detects,

…and 1 more.

Common questions about the Adapta™ ADDR01

Has the Adapta™ ADDR01 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00613994222046), based on the FDA recall file dated Nov 27, 2026. However, 16 recalls involve devices cleared under the same FDA submission. They may or may not include this model, so check the product, model and lot details in those records.

What problems have been reported with the Adapta™ ADDR01?

The FDA's MAUDE database lists 1,800 adverse event reports for this device, received between Dec 10, 2014 and Sep 28, 2026. In those reports, the most common specific device problems are “Pacing Problem” (295), “Premature Discharge of Battery” (256) and “Failure to Interrogate” (193); the most common patient problems are “Unspecified Infection” (219), “Bradycardia” (143) and “Syncope/Fainting” (66). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Adapta™ ADDR01?

39 reports are classified as deaths, 1,044 as injuries and 717 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Adapta™ ADDR01 FDA approved?

It was approved through premarket approval (PMA) P980035 on Jan 29, 1999.

Is the Adapta™ ADDR01 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the Adapta™ ADDR01, and is it still sold?

The FDA's device database lists Medtronic, Inc. as the company responsible for it (brand Adapta™, model ADDR01). Its record shows it as no longer in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.