Skip to content

Adapta™ S ADDRS1P (UDI 00613994295040)Recalls & reported problems

Medtronic, Inc. · IPG, ADDRS1P, ADAPTA, DR,IS-1,SM,CTD, US · Class 3 · Implant

Adverse event reports
4
Deaths reported
1
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00613994295040), received between Mar 27, 2018 and Sep 27, 2022 — classified as 1 death, 3 injuries.

The most frequently reported specific device problem is “Output Problem” (1 report).

16 other recalls cover devices cleared under the same FDA submission (P980035); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3
  • Output Problem1
  • Premature Discharge of Battery1

Patient problems

  • Cardiac Arrest1
  • Death1
  • Heart Block1
  • No Clinical Signs, Symptoms or Conditions1
  • No Known Impact Or Consequence To Patient1
  • Sepsis1
  • Unspecified Infection1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjurySep 27, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT POST IMPLANT OF THE IMPLANTABLE PULSE GENERATOR (IPG) THE PATIENT EXPERIENCED CONGENITAL COMPLETE HEART BLOCK. THE IPG REMAINED IN USE POST CONGENITAL COMPLETE HEART BLOCK AND WAS LATER REMOVED PROPHYLACTICALLY. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Heart Block; No Clinical Signs, Symptoms or Conditions

    MAUDE report 15493250 ↗
  • InjurySep 28, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT EXPERIENCED POCKET INFECTION. THE ABDOMINAL POCKET WAS REVISED AND THE EPICARDIAL LEADS CUT AND PARTIALLY REMOVED AND REPLACED. THE IMPLANTABLE PULSE GENERATOR (IPG) WAS EXPLANTED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Unspecified Infection

    MAUDE report 10592454 ↗
  • InjuryApr 10, 2018Premature Discharge of Battery; Output Problem; Premature Discharge of Battery; Output Problem

    IT WAS REPORTED THAT THE PATIENT'S RIGHT ATRIAL (RA) AND RIGHT VENTRICULAR (RV) LEADS EXHIBITED RISING THRESHOLD MEASUREMENTS. THE OUTPUTS WERE REPROGRAMMED ON BOTH LEADS AND THEY REMAIN IN USE. TWO DAYS LATER, THE PATIENT'S IMPLANTABLE PULSE GENERATOR (IPG) REACHED PREMATURE BATTERY DEPLETION. AT THE TIME OF THE IPG CHANGE OUT PROCEDURE, THE ELECTIVE REPLACEMENT INDICATOR (ERI) WARNING WAS ABLE TO BE CLEARED, BUT THEN THE DEVICE WAS UNABLE TO ESTIMATE BATTERY LONGEVITY. THE PHYSICIAN THEN ELECTED TO EXPLANT AND REPLACE THE DEVICE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7419733 ↗
  • DeathMar 27, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE IMPLANTABLE PULSE GENERATOR (IPG) SYSTEM WAS EXPLANTED DUE TO SUSPECTED INFECTION OF SEPSIS. THE ORGANISM HAD NOT YET BEEN IDENTIFIED. SUBSEQUENTLY, THE PATIENT DIED. A CAUSE OF DEATH WAS NOT PROVIDED. FOLLOW-UP ATTEMPTS WITH THE CLINIC RESULTED IN NO ADDITIONAL INFORMATION.

    Patient problems: Cardiac Arrest; Death; Sepsis

    MAUDE report 7373944 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under P980035. One submission often covers many models, so check the product and lot details in each record.

  • Z-2127-2025 · Jun 17, 2025 · Open, Classified
    Medtronic SmartLink Software loaded on SmartSync Patient Connector, Model Number 24967 with the following software components: 1. Azure Astra application, Software Model Number D
  • Z-2128-2025 · Jun 17, 2025 · Open, Classified
    Medtronic SmartLink software loaded on CareLink SmartSync Device Manager, Model Number 24967A with the following software components: 1. Azure Astra application, Software Model N
  • Z-1924-2025 · Apr 29, 2025 · Open, Classified
    Azure S DR MRI SureScan, Product number W3DR01
  • Z-2509-2020 · Jun 4, 2020 · Open, Classified
    Azure XT SR MRI, Model Numbers: a) W1SR01 and b) W2SR01
  • Z-2507-2020 · Jun 4, 2020 · Open, Classified
    Azure XT DR MRI, Model Numbers: a) W1DR01 and b) W2DR01
  • Z-2510-2020 · Jun 4, 2020 · Open, Classified
    Azure S SR MRI, Model Number W3SR01
  • Z-2508-2020 · Jun 4, 2020 · Open, Classified
    Azure S DR MRI, Model Number W3DR01
  • Z-0808-2019 · Jan 17, 2019 · Open, Classified
    Medtronic implantable pulse generator: RELIA, Dual chamber pacemaker (VDD): (a) Model Number RED01 (b) Model Number REDR01 (c) Model Number REVDD01
  • Z-0810-2019 · Jan 17, 2019 · Open, Classified
    Medtronic implantable pulse generator: Sphera DR MRI SureScan, Dual chamber rate responsive pacemaker (DDDR): (a) Model Number SPDR01 (b) Model Number SPDRL1
  • Z-0806-2019 · Jan 17, 2019 · Open, Classified
    Medtronic implantable pulse generator: ADAPTA, Dual chamber pacemaker (DDD): (a) Model Number ADD01 (b) Model Number ADDR01 (c) Model Number ADDR03 (d) Model Number ADDR06 (e) Mo
  • Z-0811-2019 · Jan 17, 2019 · Open, Classified
    Medtronic implantable pulse generator: Versa, Dual chamber rate responsive pacemaker (DDDR), Model Number VEDR01
  • Z-0807-2019 · Jan 17, 2019 · Open, Classified
    Medtronic implantable pulse generator: ATTESTA L DR MRI SureScan, Dual chamber rate responsive pacemaker (DDDR): (a) Model Number ATDR01 (b) Model Number ATDRL1 (c) Model Number
  • Z-0809-2019 · Jan 17, 2019 · Open, Classified
    Medtronic implantable pulse generator: SENSIA, Dual chamber pacemaker (DDD): (a) Model Number SED01 (b) Model Number SEDR01 (c) Model Number SEDRL1
  • Z-2120-2011 · Apr 4, 2011 · Terminated
    Medtronic, Kappa 600 KDR600,KDR601,KDR603,KDR606,KDR651,KDR653 The devices are implantable pulse generators (IPG) used to detect bradycardia events and provide pacing support. Wit
  • Z-1440-2010 · Feb 11, 2010 · Terminated
    Medtronic EnRhythm, P1501DR, Dual Chamber Rate Responsive Pacemaker with RapidRead Telemetry. The EnRhythm pacing system is an implantable medical device that monitors, detects,

…and 1 more.

Other Implantable pulse generator, pacemaker (non-CRT) devices

All Implantable pulse generator, pacemaker (non-CRT) devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.