Atellica IM CEA 10995524Recalls & reported problems

Siemens Healthcare Diagnostics Inc. · CEA Atellica IM - RGT - 500T · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00630414598512), received between Apr 4, 2022 and Jan 23, 2026 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Low Test Results” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Low Test Results2
  • High Test Results1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 23, 2026Low Test Results

    THE CUSTOMER REPORTS OBSERVATION OF DEPRESSED ATELLICA IM CARCINOEMBRYONIC ANTIGEN (CEA) RESULTS WHICH WERE DISCORDANT RELATIVE TO REPEAT TESTING WHEN USING CEA LOT 226. THE CUSTOMER INDICATES THAT SOME SAMPLES HAVE PRODUCED FALSELY-DEPRESSED ATELLICA IM CEA RESULTS WHICH DISAGREED WITH HIGHER RESULTS PRODUCED UPON REPEAT TESTING USING THE SAME INSTRUMENT. THERE ARE NO ALLEGATIONS OF ANY ADVERSE PATIENT CONSEQUENCES IN ASSOCIATION WITH THE DISCORDANT OBSERVATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24162041 ↗
  • MalfunctionMay 16, 2024High Test Results; High Test Results

    THE CUSTOMER REPORTS OBSERVATION OF ELEVATED ATELLICA IM CARCINOEMBRYONIC ANTIGEN (CEA) RESULTS WHICH WERE DISCORDANT RELATIVE TO REPEAT TESTING. CEA LOT 218 WAS IN USE AT THE TIME. ELEVATED RESULTS WERE OBSERVED FOR 18 PATIENTS. THE RESULTS WERE VERY HIGH, AND WERE NOT REPORTED TO PHYSICIANS. THE SAME SAMPLES WERE REPEAT-TESTED USING ANOTHER REAGENT PACK FROM THE SAME LOT, AND ALL OF THE RESULTS WERE MUCH LOWER. THESE LOWER RESULTS WERE CONSISTENT WITH CLINICAL EXPECTATION, AND REPORTED TO PHYSICIANS. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE DISCORDANT ELEVATED CEA RESULTS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19333287 ↗
  • MalfunctionApr 4, 2022Low Test Results; Low Test Results

    THE CUSTOMER OBTAINED A DISCORDANT FALSELY DEPRESSED CARCINOEMBRYONIC ANTIGEN (CEA) RESULT FOR A PATIENT SAMPLE ON AN ATELLICA IM ANALYZER (B)(4) WHEN COMPARED TO A PREVIOUS HIGHER RESULT FROM (B)(6) 2022. THE PATIENT SAMPLE WAS REPEATED ON THE ORIGINAL AND ALTERNATE (B)(4) ATELLICA IM ANALYZERS. THE RESULTS FROM THE ORIGINAL ATELLICA IM ANALYZER SHOWED DISCORDANCY BETWEEN RESULTS. THE RESULT FROM THE ALTERNATE ATELLICA IM ANALYZER WAS HIGHER THAN THE INITIAL DEPRESSED RESULT AND SIMILAR TO THE PREVIOUS RESULT FROM (B)(6) 2022. THE INITIAL CEA RESULT WAS NOT REPORTED TO THE PHYSICIAN. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE DISCORDANT CEA RESULTS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14002764 ↗

Other SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN devices

All SYSTEM, TEST, CARCINOEMBRYONIC ANTIGEN devices →