Atellica IM CKMB 10995531Recalls & reported problems
Siemens Healthcare Diagnostics Inc. · CKMB Atellica IM - RGT 500T · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00630414598581), received between Aug 13, 2021 and Dec 5, 2024 — classified as 2 malfunctions.
The most frequently reported specific device problem is “High Test Results” (2 reports).
5 other recalls cover devices cleared under the same FDA submission (K962126); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- High Test Results2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 5, 2024High Test Results; High Test Results
THE CUSTOMER REPORTS OBSERVATION OF ELEVATED ATELLICA IM CREATINE KINASE MB (CKMB, LOT 279) RESULTS WHICH WERE DISCORDANT RELATIVE TO REPEAT TESTING USING LOT 281. INITIAL ELEVATED RESULTS WERE OBTAINED FOR FOUR (4) PATIENT SAMPLES. THE INITIAL RESULTS WERE NOT REPORTED TO THE PHYSICIAN(S). THE SAME SAMPLES WERE THEN RETESTED USING AN ALTERNATE REAGENT LOT 281 AND OBTAINED LOWER RESULTS. THE LOWER RESULTS MATCHED THE CLINICAL PICTURES OF THE PATIENTS, CONSIDERED CORRECT AND REPORTED TO THE PHYSICIAN(S). THERE ARE NO ALLEGATIONS OF PATIENT HARM, CHANGES IN TREATMENT, OR DELAYS OF DIAGNOSIS OR TREATMENT RESULTING FROM THE OBSERVED RESULT DISCORDANCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20852785 ↗MalfunctionAug 13, 2021High Test Results; High Test Results
A CUSTOMER OBSERVED AN ELEVATED ATELLICA IM CREATINE KINASE MB (CKMB) IMMUNOASSAY RESULT COMPARED TO LOW CK ISOENZYME ELECTROPHORESIS RESULTS. THE INITIAL RESULT WAS REPORTED AND QUESTIONED BY THE PHYSICIAN. THE PHYSICIAN BELIEVES THERE IS AN ABNORMAL HIGH CKMB BY IMMUNOASSAY COMPARED TO CK ISOENZYME BY ELECTROPHORESIS. THE SAMPLE WAS NOT RETESTED USING ATELLICA IM CREATINE KINASE MB (CKMB). THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE ELEVATED ATELLICA IM CKMB RESULT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12319406 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K962126. One submission often covers many models, so check the product and lot details in each record.
- Z-0115-2019 · Jul 24, 2018 · TerminatedADVIA Centaur CKMB Master Curve Material, Cat No. 07867768 Product Usage: For in vitro diagnostic use for evaluating the ADVIA Centaur CKMB assay. This material is intended to be
- Z-0116-2019 · Jul 24, 2018 · TerminatedAtellica IM CKMB Calibrator, Cat No. 10995532 Product Usage: For in vitro diagnostic use for evaluating the ADVIA Centaur CKMB assay. This material is intended to be run singly a
- Z-0117-2019 · Jul 24, 2018 · TerminatedAtellica IM CKMB Master Curve Material, Cat No. 10995534 Product Usage: For in vitro diagnostic use for evaluating the ADVIA Centaur CKMB assay. This material is intended to be r
- Z-0114-2019 · Jul 24, 2018 · TerminatedADVIA Centaur CKMB Calibrator 2-pack Japan, Cat No. 02562748 Product Usage: For in vitro diagnostic use in calibrating ADVIA Centaur systems CKMB assays.
- Z-0113-2019 · Jul 24, 2018 · TerminatedADVIA Centaur CKMB Calibrator, Cat No. 09318028 Product Usage: For in vitro diagnostic use in calibrating ADVIA Centaur systems CKMB assays.
Other DIFFERENTIAL RATE KINETIC METHOD, CPK OR ISOENZYMES devices
- Creatine Kinase 7190794190Roche Diagnostics GmbH · DIFFERENTIAL RATE KINETIC METHOD, CPK OR ISOENZYMES1 recall11 reports
- VITROS 8001133Ortho-Clinical Diagnostics, Inc. · DIFFERENTIAL RATE KINETIC METHOD, CPK OR ISOENZYMES1 recall10 reports
- VITROS 8058232Ortho-Clinical Diagnostics, Inc. · DIFFERENTIAL RATE KINETIC METHOD, CPK OR ISOENZYMES1 recall9 reports
- Atellica IM CKMB Calibrator 10995532Siemens Healthcare Diagnostics Inc. · DIFFERENTIAL RATE KINETIC METHOD, CPK OR ISOENZYMES1 recall0 reports
- ADVIA Centaur® Systems, ACS:180® Systems CKMB Calibrator 10311570Siemens Healthcare Diagnostics Inc. · DIFFERENTIAL RATE KINETIC METHOD, CPK OR ISOENZYMES1 recall0 reports
- Atellica IM CKMB 10995530Siemens Healthcare Diagnostics Inc. · DIFFERENTIAL RATE KINETIC METHOD, CPK OR ISOENZYMES2 reports
- Creatine Kinase 08057460190Roche Diagnostics GmbH · DIFFERENTIAL RATE KINETIC METHOD, CPK OR ISOENZYMES1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page