Creatine Kinase 08057460190Recalls & reported problems
Roche Diagnostics GmbH · Class 2
All models of Creatine Kinase (3)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613336121122), received between Apr 11, 2026 and Apr 11, 2026 — classified as 1 malfunction.
The most frequently reported specific device problem is “High Test Results” (1 report).
1 other recall cover devices cleared under the same FDA submission (K160570); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- High Test Results1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 11, 2026High Test Results
THERE WAS AN ALLEGATION OF QUESTIONABLE CREATINE KINASE RESULTS FOR 3 PATIENT SAMPLES ON A COBAS C 503 ANALYTICAL UNIT. THE CUSTOMER REPEATED PREVIOUS PATIENT SAMPLES ON A NEW REAGENT LOT AS THEY WERE HAVING ISSUES WITH QC RECOVERING HIGH. SAMPLE 1 HAD AN INITIAL RESULT OF 79.0 U/L. THE SAMPLE WAS REPEATED ON ANOTHER ANALYZER AND THE RESULT WAS 67.5 U/L. ON (B)(6) 2026, THE SAMPLE WAS REPEATED ON THE INITIAL ANALYZER WITH A NEW REAGENT LOT AND THE RESULT WAS 59.5 U/L. SAMPLE 2 HAD AN INITIAL RESULT OF 62.0 U/L. THE SAMPLE WAS REPEATED ON ANOTHER ANALYZER AND THE RESULT WAS 48.0 U/L. ON (B)(6) 2026, THE SAMPLE WAS REPEATED ON THE INITIAL ANALYZER WITH A NEW REAGENT LOT AND THE RESULT WAS 47.6 U/L. SAMPLE 3 HAD AN INITIAL RESULT OF 15075.0 U/L. ON (B)(6) 2026, THE SAMPLE WAS REPEATED WITH A NEW REAGENT LOT AND THE RESULT WAS 9683 U/L. THE REPEAT RESULTS FROM THE NEW REAGENT LOT WERE DEEMED CORRECT. CLARIFICATION ON WHETHER THE INITIAL RESULTS WERE PRODUCED ON (B)(6)2026 WAS NOT PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24851932 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K160570. One submission often covers many models, so check the product and lot details in each record.
- Z-3187-2024 · Aug 15, 2024 · Open, ClassifiedCreatine Kinase (CK) used on cobas c 311/501/502 and COBAS INTEGRA 400 plus-In vitro test for the quantitative determination of creatine kinase (CK) in human serum and plasma. Cata
Other DIFFERENTIAL RATE KINETIC METHOD, CPK OR ISOENZYMES devices
- Creatine Kinase 7190794190Roche Diagnostics GmbH · DIFFERENTIAL RATE KINETIC METHOD, CPK OR ISOENZYMES1 recall11 reports
- VITROS 8001133Ortho-Clinical Diagnostics, Inc. · DIFFERENTIAL RATE KINETIC METHOD, CPK OR ISOENZYMES1 recall10 reports
- VITROS 8058232Ortho-Clinical Diagnostics, Inc. · DIFFERENTIAL RATE KINETIC METHOD, CPK OR ISOENZYMES1 recall9 reports
- ADVIA Centaur® Systems, ACS:180® Systems CKMB Calibrator 10311570Siemens Healthcare Diagnostics Inc. · DIFFERENTIAL RATE KINETIC METHOD, CPK OR ISOENZYMES1 recall0 reports
- Atellica IM CKMB Calibrator 10995532Siemens Healthcare Diagnostics Inc. · DIFFERENTIAL RATE KINETIC METHOD, CPK OR ISOENZYMES1 recall0 reports
- Atellica IM CKMB 10995531Siemens Healthcare Diagnostics Inc. · DIFFERENTIAL RATE KINETIC METHOD, CPK OR ISOENZYMES2 reports
- Atellica IM CKMB 10995530Siemens Healthcare Diagnostics Inc. · DIFFERENTIAL RATE KINETIC METHOD, CPK OR ISOENZYMES2 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page