NA 5846AL (UDI 00643169431669)Recalls & reported problems

Medtronic, Inc. · CABLE 5846AL ROHS GLB 12FT 5PK 10L · Class 3

Adverse event reports
18
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 18 adverse event reports that list this exact device (DI 00643169431669), received between May 9, 2022 and Oct 16, 2023 — classified as 1 injury, 17 malfunctions.

The most frequently reported specific device problem is “Material Integrity Problem” (18 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Integrity Problem18

Patient problems

  • No Clinical Signs, Symptoms or Conditions17
  • Ventricular Fibrillation1

Recent adverse event reports

The 18 most recent of 18 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 16, 2023Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT THE PATIENT CABLE DID NOT HAVE AN OPTIMAL CONNECTION WITH THE PACING CATHETER. IT WAS NOTED THAT IT WAS NOT POS SIBLE TO FULLY INSERT THE CATHETER CONNECTORS INTO THE PATIENT CABLE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17937615 ↗
  • MalfunctionSep 21, 2023Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT THE SURGICAL CABLE WAS UNABLE TO CLICK AND STAY IN PLACE IN THE EXTERNAL PULSE GENERATOR (EPG), HENCE THE EPG WAS UNABLE TO PACE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17794618 ↗
  • MalfunctionJul 24, 2023Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT THE PATIENT CABLE WAS UNABLE TO CONNECT WITH THE JUMPER CABLE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17377330 ↗
  • MalfunctionJul 24, 2023Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT THE PATIENT CABLE WAS UNABLE TO CONNECT WITH THE JUMPER CABLE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17377093 ↗
  • MalfunctionJul 24, 2023Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT THE PATIENT CABLE WAS UNABLE TO CONNECT WITH THE JUMPER CABLE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17377038 ↗
  • MalfunctionMay 23, 2023Material Integrity Problem; Material Integrity Problem

    THE PATIENT CABLE (ATRIAL) WAS UNABLE TO CONNECT WITH THE ADAPTER CABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16984994 ↗
  • MalfunctionMay 23, 2023Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT THE SURGICAL CABLES WERE UNABLE TO CONNECT WITH THE ADAPTER CABLE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16984967 ↗
  • MalfunctionMay 23, 2023Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT THE SURGICAL CABLES WERE UNABLE TO CONNECT WITH THE ADAPTER CABLE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16984922 ↗
  • MalfunctionMay 23, 2023Material Integrity Problem; Material Integrity Problem

    THE PATIENT CABLE (ATRIAL) WAS UNABLE TO CONNECT WITH THE ADAPTER CABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16984893 ↗
  • MalfunctionMay 23, 2023Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT THE SURGICAL CABLES WERE UNABLE TO CONNECT WITH THE ADAPTER CABLE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16984814 ↗
  • MalfunctionMay 23, 2023Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT THE SURGICAL CABLES WERE UNABLE TO CONNECT WITH THE ADAPTER CABLE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16984253 ↗
  • MalfunctionMay 23, 2023Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT THE SURGICAL CABLES WERE UNABLE TO CONNECT WITH THE ADAPTER CABLE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16984125 ↗
  • MalfunctionMay 23, 2023Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT THE SURGICAL CABLES WERE UNABLE TO CONNECT WITH THE ADAPTER CABLE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16984033 ↗
  • MalfunctionMay 23, 2023Material Integrity Problem; Material Integrity Problem

    THE PATIENT CABLE (ATRIAL) WAS UNABLE TO CONNECT WITH THE ADAPTER CABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16984003 ↗
  • MalfunctionMay 23, 2023Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT THE SURGICAL CABLES WERE UNABLE TO CONNECT WITH THE ADAPTER CABLE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16983966 ↗
  • InjuryNov 2, 2022Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT THE CABLE'S CONNECTORS WERE TOO SMALL TO DELIVER TEMPORARY PACING AND AS A RESULT A PATIENT ALMOST REQUIRED A SHOCK DUE TO POLYMORPHIC VENTRICULAR TACHYCARDIA (PMVT). THE PATIENT SUFFERED VENTRICULAR FIBRILLATION AND MEDICAL INTERVENTION WAS REQUIRED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Ventricular Fibrillation

    MAUDE report 15714659 ↗
  • MalfunctionJul 13, 2022Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT THE CABLE WAS NOT ABLE TO CORRECTLY CONNECT TO THE EXTERNAL PULSE GENERATOR (EPG). NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14998143 ↗
  • MalfunctionMay 9, 2022Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT THE CABLE WOULD NOT TIGHTLY CONNECT TO THE PACING CATHETER OR STAY IN PLACE. AN ALTERNATIVE CABLE WAS USED. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14336802 ↗

Other Implantable pulse generator, pacemaker (non-CRT) devices