Viva™ S CRT-D DTBB1D4 (UDI 00643169530195)Recalls & reported problems

Medtronic, Inc. · CRT-D DTBB1D4 VIVA S US DF4 · Class 3 · Implant

All models of Viva S CRT-D (8)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
8
Deaths reported
0
Injuries reported
6
Recalls naming it
1

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 00643169530195), received between Jun 8, 2017 and Jun 12, 2024 — classified as 6 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Premature Discharge of Battery” (3 reports).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Feb 3, 2021Class IOpen, Classified

    A small percentage of implanted cardiac devices, from a well-defined subset, may experience a shortened Recommended Replacement Time (RRT) to End of Service (EOS) interval following an earlier-than-expected RRT observation

    Z-1306-2021 · Root cause: Device Design · Recall details · FDA record ↗

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3
  • Premature Discharge of Battery3
  • Failure to Interrogate1
  • Migration or Expulsion of Device1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Unspecified Infection2
  • Hematoma1
  • Inflammation1
  • No Known Impact Or Consequence To Patient1
  • Sepsis1
  • Shock from Patient Lead(s)1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 12, 2024Migration or Expulsion of Device; Migration or Expulsion of Device

    IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) MIGRATED DOWN OVER THE YEARS AND IS MOVING UNDER THE PATIENT ARMPIT AND IS UNCOMFORTABLE.  THE DEVICE REMAINS IN USE.  THE PATIENT IS A PARTICIPANT IN A CLINICAL STUDY.  NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19522261 ↗
  • InjuryApr 7, 2022Premature Discharge of Battery; Premature Discharge of Battery

    IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) EXHIBITED POSSIBLE PREMATURE BATTERY DEPLETION. THE CRT-D WAS EXPLANTED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14042105 ↗
  • InjuryMar 14, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SYSTEM WAS EXPLANTED DUE TO AN INFECTION. IT WAS NOTED THAT ANTIBIOTIC TREATMENT WAS NECESSARY. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Inflammation; Unspecified Infection

    MAUDE report 13763547 ↗
  • InjuryAug 9, 2021Premature Discharge of Battery; Premature Discharge of Battery

    IT WAS REPORTED THAT THERE WAS PREMATURE BATTERY DEPLETION ON THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D). THE DEVICE WAS EXPLANTED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12293955 ↗
  • MalfunctionFeb 5, 2021Premature Discharge of Battery; Premature Discharge of Battery

    IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) EXHIBITED PREMATURE BATTERY DEPLETION. THE DEVICE REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11285459 ↗
  • InjuryFeb 17, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SYSTEM WAS EXPLANTED DUE TO SEPSIS AND THE VEGETATION ON THE LEADS. CULTURES WERE TAKEN. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Sepsis; Unspecified Infection

    MAUDE report 9716973 ↗
  • MalfunctionJan 29, 2020Failure to Interrogate; Failure to Interrogate

    IT WAS REPORTED THAT THE PATIENT PRESENTED TO HEALTHCARE FACILITY FOR EVALUATION DUE TO COMPLAINTS OF DIAPHRAGMATIC STIMULATION THOUGHT TO BE DUE TO PACING. THE PATIENT SYMPTOMS HAVE BEEN INTERMITTENT FOR APPROXIMATELY SIX AND A HALF MONTHS. THE PATIENT BELIEVES THE DIAPHRAGMATIC STIMULATION IS POSITIONAL, AND IS VERY ANNOYING BUT NOT PAINFUL. UPON INTERROGATION OF THE ASSOCIATED CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D), WITH THE ENCORE PROGRAMMER, INTERROGATION FAILS AT TWENTY PERCENT. MULTIPLE ATTEMPTS TO INTERROGATE THE CRT-D RESULT IN SAME OUTCOME. IT WAS ALSO REPORTED THAT THE PATIENT HAS A NON MEDTRONIC LEFT VENTRICULAR ASSIST DEVICE (LVAD), THAT GIVES OFF ENOUGH ELECTROMAGNETIC INTERFERENCE IT INTERFERES WITH CRT-D - PROGRAMMER COMMUNICATION WHEN USING NON WIRELESS TELEMETRY. TROUBLESHOOTING STEPS WERE ADVISED. IF TROUBLESHOOTING WAS UNSUCCESSFUL THE PATIENT WOULD BE RE-SCHEDULED FOR FOLLOW UP EVALUATION AT A DIFFERENT FACILITY. THE CRT-D, LV LEAD AND ENCORE PROGRAMMER REMAIN IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9644356 ↗
  • InjuryJun 8, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT HAD AN IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) POCKET REVISION FOR HEMATOMA. DURING THE ICD POCKET REVISION, THE RIGHT VENTRICULAR (RV) LEAD HAD NOISE OVERSENSING DURING ELECTROCAUTERY USE AND DELIVERED UNEXPECTED SHOCK THERAPIES TO THE PATIENT. THE ICD AND RV LEAD REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Hematoma; Shock from Patient Lead(s)

    MAUDE report 6628695 ↗

Other Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D) devices

All Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D) devices →