Gallant™ CDHFA500QRecalls & reported problems

St. Jude Medical, Inc. · HF Cardiac Resynchronisation Therapy Defibrillator VVED DDDRV · Class 3 · Implant

2 open recalls name this device. See the recall details and contact the manufacturer or your healthcare provider.

Quick summary

This St. Jude Gallant CRT-D defibrillator appears in 8,303 adverse event reports, including 58 deaths and 957 injuries. The reports mostly describe over-sensing, where the device reads false heart signals, failures to be checked by the clinic, and inappropriate shocks. Both of its 2 recalls are open: one about Bluetooth failures in some devices made before April 2022, and one about Bluetooth problems that block remote monitoring and can shorten battery life.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
8,401
Deaths reported
58
Injuries reported
957
Recalls naming it
2

Summary

The FDA's MAUDE database contains 8,401 adverse event reports that list this exact device (DI 05415067032010), received between Aug 21, 2020 and Sep 30, 2026 — classified as 58 deaths, 957 injuries, 7,384 malfunctions.

The most frequently reported specific device problem is “Over-Sensing” (5,803 reports).

2 FDA recall records name this device's identifier, 2 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 161 reportsDec 2023: 120 reportsJan 2024: 162 reportsFeb 2024: 165 reportsMar 2024: 145 reportsApr 2024: 187 reportsMay 2024: 166 reportsJun 2024: 165 reportsJul 2024: 124 reportsAug 2024: 140 reportsSep 2024: 150 reportsOct 2024: 185 reportsNov 2024: 183 reportsDec 2024: 106 reportsJan 2025: 145 reportsFeb 2025: 144 reportsMar 2025: 160 reportsApr 2025: 120 reportsMay 2025: 172 reportsJun 2025: 147 reportsJul 2025: 148 reportsAug 2025: 138 reportsSep 2025: 101 reportsOct 2025: 107 reportsNov 2025: 141 reportsDec 2025: 159 reportsJan 2026: 133 reportsFeb 2026: 157 reportsMar 2026: 156 reportsApr 2026: 148 reportsMay 2026: 127 reportsJun 2026: 100 reportsJul 2026: 34 reportsAug 2026: 116 reportsSep 2026: 155 reportsOct 2026: 0 reports202420252026187
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Aug 16, 2023Open, Classified

    Due to Bluetooth malfunction on a subset of Implantable Cardioverter Defibrillator (ICD) and Cardia Resynchronization Therapy Defibrillator *CRT-D) devices that were manufactured prior to April 2022 as a result of crystal component issue within the Bluetooth Low Energy (BLE) circuit. This results in the device entering an inductive telemetry only mode with loss of Bluetooth communication. In some instances, thought BLE communication is unavailable, the circuit may remain in a state which draws excessive power affecting battery longevity.

    Z-2615-2023 · Root cause: Component design/selection · FDA record ↗

  2. Mar 10, 2022Open, Classified

    Bluetooth malfunction impacting Gallant devices post-implant. The failure causes the device to enter an inductive-only telemetry mode with a loss of Bluetooth communication. The Bluetooth malfunction results in the inability to remotely monitor these devices and resulted in reduced battery longevity.

    Z-0990-2022 · Root cause: Component design/selection · FDA record ↗

Most reported problems

Device problems

  • Over-Sensing5,803
  • Failure to Interrogate784
  • Adverse Event Without Identified Device or Use Problem530
  • Pacing Problem270
  • Inappropriate/Inadequate Shock/Stimulation258
  • Under-Sensing228
  • Pacing Asynchronously192
  • Inappropriate or Unexpected Reset148

Patient problems

  • No Clinical Signs, Symptoms or Conditions7,457
  • Unspecified Infection436
  • Insufficient Information290
  • Arrhythmia148
  • Discomfort97
  • Pocket Erosion92
  • Wound Dehiscence50
  • No Consequences Or Impact To Patient33

Recent adverse event reports

The 25 most recent of 8,401 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 30, 2026Failure to Interrogate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50954796 ↗
  • MalfunctionSep 30, 2026Failure to Interrogate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50952947 ↗
  • MalfunctionSep 30, 2026Inappropriate or Unexpected Reset

    It was reported that the Implantable Cardioverter Defibrillator (ICD) was found to be in back-up operation mode before implanting.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50950891 ↗
  • MalfunctionSep 30, 2026Failure to Interrogate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50949880 ↗
  • MalfunctionSep 30, 2026Over-Sensing

    It was reported during remote follow up that the Implantable Cardioverter Defibrillator (ICD) exhibited Post-Paced T-wave Oversensing (PPTWOS). The product will continue to be monitored. There were no patient consequences.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50949641 ↗
  • MalfunctionSep 30, 2026Over-Sensing

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50949372 ↗
  • MalfunctionSep 30, 2026Over-Sensing; Pacing Asynchronously

    During remote follow up, post paced T wave oversensing and fusion were observed on the device. Technical Support was contacted and recommended reprogramming. No intervention has been performed. The patient was stable.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50946520 ↗
  • InjurySep 30, 2026Premature Discharge of Battery

    It was reported that the implantable cardioverter defibrillator exhibited premature battery depletion. The device was explanted and replaced. The patient was in stable condition.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50941921 ↗
  • MalfunctionSep 29, 2026No Apparent Adverse Event

    Patient problems: Insufficient Information

    MAUDE report 50939899 ↗
  • MalfunctionSep 29, 2026Failure to Interrogate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50937634 ↗
  • MalfunctionSep 29, 2026Environmental Compatibility Problem; Inappropriate or Unexpected Reset

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50937616 ↗
  • MalfunctionSep 29, 2026Failure to Interrogate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50937349 ↗
  • MalfunctionSep 29, 2026Incorrect, Inadequate or Imprecise Result or Readings

    It was reported that the patient's Implantable Cardioverter Defibrillator (ICD) exhibited a Synchrony Atrioventricular (Sync AV) Delta marker that displayed at the end instead of the beginning of the sequence. No changes or interventions were reported. The patient condition was not known.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50934240 ↗
  • MalfunctionSep 29, 2026Over-Sensing

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50933708 ↗
  • InjurySep 29, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the patient presented to the clinic due to pocket erosion. The physician explanted the entire ICD system due to erosion. The patient was in stable condition throughout the procedure.

    Patient problems: Pocket Erosion

    MAUDE report 50932638 ↗
  • MalfunctionSep 29, 2026Over-Sensing

    It was reported that the patient presented remotely via Merlin.net. It was noted that the Implantable Cardioverter Defibrillator (ICD) exhibited Post-Paced T-wave Oversensing (PPTWOS). No intervention was performed. There were no patient consequences.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50927843 ↗
  • MalfunctionSep 29, 2026Over-Sensing

    It was reported that the patient presented remotely via Merlin.net. It was noted that the Implantable Cardioverter Defibrillator (ICD) exhibited Post-Paced T-wave Oversensing (PPTWOS). No intervention was performed. There were no patient consequences.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50927812 ↗
  • MalfunctionSep 29, 2026Over-Sensing

    It was reported that the patient's Implantable Cardioverter Defibrillator (ICD) exhibited Post-Paced T-wave Oversensing (PPTWOS). No further information was provided.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50927653 ↗
  • InjurySep 29, 2026High impedance; Loose or Intermittent Connection

    It was reported that the patient underwent a device exchange procedure on (b)(6) 2026. After the procedure, the patient was monitored remotely via Merlin.net. Review of the transmission revealed that the right ventricular (RV) lead exhibited high, out-of-range defibrillation impedance, and the left ventricular (LV) lead exhibited high, out-of-range pacing impedance. Diagnostic imaging confirmed that the leads were not properly secured in the set screws of the Implantable Cardioverter Defibrillator (ICD). During the lead revision procedure, the RV lead was found to be disconnected from the ICD, and the LV lead was also found to be loose. The RV and LV leads were cleaned and secured by tightening the set screws, and the impedance values returned to the normal range. The patient remained stable throughout the procedure.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50927573 ↗
  • MalfunctionSep 28, 2026Failure to Interrogate

    It was reported that the patient's Implantable Cardioverter Defibrillator exhibited loss of Bluetooth telemetry. No intervention was performed. There were no patient consequences.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50916906 ↗
  • MalfunctionSep 28, 2026Over-Sensing; Pacing Problem

    It was reported that a patient presented remotely via Merlin.net. Review of the transmission revealed far-field R-wave oversensing resulted in inappropriate Automatic Mode Switch (AMS). Programming changes were discussed, no changes or interventions were reported. There were no patient consequences.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50916409 ↗
  • MalfunctionSep 28, 2026Over-Sensing

    It was reported that the patient's Implantable Cardioverter Defibrillator (ICD) exhibited post-paced t-wave oversensing. No intervention was performed and the patient's status was unknown.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50910854 ↗
  • InjurySep 28, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the patient presented to the hospital with infection and was tested positive for bacteremia. The physician stated that the infection was not caused by Abbotts' devices. The patient's implantable cardioverter-defibrillator, the right atrial lead, the right ventricular lead and the left ventricular lead were explanted due to the infection. The patient was stable throughout.

    Patient problems: Unspecified Infection

    MAUDE report 50910621 ↗
  • MalfunctionSep 26, 2026Over-Sensing

    Patient problems: Insufficient Information

    MAUDE report 50906570 ↗
  • MalfunctionSep 25, 2026Over-Sensing

    During a remote follow-up, episodes of post-paced T wave oversensing were observed on the device. Technical Support was contacted, but no intervention has been performed at this time. The patient was stable.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50903455 ↗

Other Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D) devices

All Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D) devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.