Azure™ S DR MRI SureScan™ W3DR01 (UDI 00643169634602)Recalls & reported problems
Medtronic, Inc. · IPG W3DR01 AZURE S DR MRI WL USA · Class 3 · Implant
All models of Medtronic Azure Pacemaker (12) · Azure S DR MRI SureScan (3)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
Quick summary
This Medtronic Azure S DR MRI SureScan pacemaker is a permanent implant. Its 711 reports, including 12 deaths and 408 injuries, mostly describe pacing problems, early battery drain and false alarms. Recent reports include irregular or slow heart rates, lead sensing errors, and a programmer that could not connect after MRI mode. No recalls name this device, and reports in the last 12 months number 16, down from 28 in the year before.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 715
- Deaths reported
- 12
- Injuries reported
- 411
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 715 adverse event reports that list this exact device (DI 00643169634602), received between Apr 10, 2018 and Sep 10, 2026 — classified as 12 deaths, 411 injuries, 292 malfunctions.
The most frequently reported specific device problem is “Pacing Problem” (84 reports).
16 other recalls cover devices cleared under the same FDA submission (P980035); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem242
- Pacing Problem84
- Premature Discharge of Battery71
- Appropriate Device Problem Term/Code Not Available68
- False Alarm44
- Mechanical Problem35
- Reset Problem30
- Inappropriate or Unexpected Reset27
Patient problems
- No Clinical Signs, Symptoms or Conditions185
- Unspecified Infection172
- No Known Impact Or Consequence To Patient122
- No Consequences Or Impact To Patient48
- Bradycardia30
- Dizziness18
- Pocket Erosion16
- Bacterial Infection15
Recent adverse event reports
The 25 most recent of 715 reports, in the reporter's own words as published by the FDA.
InjurySep 10, 2026Appropriate Device Problem Term/Code Not Available
It was reported that the Implantable Pulse Generator (IPG) was removed and replaced for an unknown reason. No patient complications have been reported as a result of this event.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50708960 ↗MalfunctionSep 9, 2026Migration or Expulsion of Device
It was reported by the patient that the Implantable Pulse Generator (IPG) moved and was protruding and they pushed it back into place. The IPG remains in use. No patient complications have been reported as a result of this event.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50688278 ↗InjurySep 9, 2026Premature Discharge of Battery
It was reported that the Right Atrial (RA) lead and Right Ventricular (RV) lead exhibited high thresholds. The leads were explanted and replaced. No patient complications have been reported as a result of this event. It was further reported that that the Implantable Pulse Generator (IPG) was explanted and replaced due to early battery depletion due to high thresholds.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50685812 ↗InjurySep 1, 2026Adverse Event Without Identified Device or Use Problem
Patient problems: Medical device site infection
MAUDE report 50542917 ↗InjuryJun 24, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED BY THE PATIENT THAT THEIR HEART RATE WAS ''ALL OVER THE PLACE'' AND THAT THEY HAD BEEN HOSPITALIZED. THE IMPLANTABLE PULSE GENERATOR (IPG) SYSTEM REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Arrhythmia
MAUDE report 25605920 ↗MalfunctionMay 27, 2026False Alarm
IT WAS REPORTED THAT THE IMPLANTABLE PULSE GENERATOR (IPG) EXHIBITED A FALSE ATRIAL LOW LEAD IMPEDANCE WARNING. THE IPG REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25301441 ↗MalfunctionMay 21, 2026Communication or Transmission Problem
IT WAS REPORTED THAT CONNECTION OF THE PATIENT CONNECTOR TO THE MOBILE PROGRAMMER APPLICATION COULD NOT BE COMPLETED WHILE ATTEMPTING TO REMOVE AN IMPLANTABLE PULSE GENERATOR (IPG) FROM MAGNETIC RESONANCE IMAGING (MRI) MODE. TROUBLESHOOTING STEPS WERE TAKEN TO INCLUDE TOGGLING BLUETOOTH, FORCE CLOSING THE APPLICATION, ATTEMPTING PAIRING MULTIPLE TIMES UNTIL BLUETOOTH PAIRING WAS ACHIEVED. IT WAS THEN NOTED THAT THE CONNECTOR WAS UNABLE TO CONNECT TO THE IPG REMAINING ON THE LOOKING FOR DEVICE SCREEN. ADDITIONAL TROUBLESHOOTING STEPS WERE TAKEN TO INCLUDE REPOSITIONING THE CONNECTOR OVER THE IPG AND REBOOTING THE HOST TABLET; HOWEVER, THE ISSUE PERSISTED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25242331 ↗MalfunctionMay 19, 2026Pacing Problem
IT WAS REPORTED THAT THE PATIENT EXPERIENCED BRADYCARDIA. UPON DEVICE ASSESSMENT IT WAS NOTED THAT THE RIGHT ATRIAL (RA) LEAD EXHIBITED FAR FIELD R-WAVE (FFRW) OVERSENSING, TRIGGERING ATRIAL TACHYCARDIA (AT)/ATRIAL FIBRILLATION (AF) DETECTIONS. REPORTS OF HEART RATES IN THE TWENTIES WERE REPORTED, WITH POSSIBLE NON-CAPTURE ON THE RIGHT VENTRICULAR (RV) LEAD. THE IMPLANTABLE PULSE GENERATOR (IPG) SYSTEM REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Bradycardia
MAUDE report 25214152 ↗MalfunctionApr 9, 2026Premature Discharge of Battery
IT WAS REPORTED THAT THE PATIENT EXPERIENCED CHEST PAIN. IT WAS REPORTED THAT THE IMPLANTABLE PULSE GENERATOR (IPG) EXHIBITED HIGHER BATTERY DRAIN. THE IPG REMAINS IN USE. IT WAS ALSO REPORTED THAT THE RIGHT ATRIAL (RA) LEAD AND THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED OVERSENSING AND POSSIBLE NOISE ON EPISODES RESULTING IN INHIBITION OF PACING AND MISCLASSIFICATION OF EPISODE TYPE. IT WAS REPORTED THAT THE RA LEAD EXHIBITED INTERMITTENT UNDERSENSING ON STORED EPISODES RESULTING IN MISCLASSIFICATION OF A NON-SUSTAINED VENTRICULAR TACHYCARDIA EPISODE, TERMINATION OF ATRIAL TACHYCARDIA/ATRIAL FIBRILLATION (AT/AF) DETECTED EVENTS IN PROGRESS, AND UNNECESSARY PACING AT TIMES. THE RA LEAD REMAINS IN USE. IT WAS ALSO REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED A HIGH NUMBER OF SHORT V-V INTERVALS. THE RV LEAD REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Chest Pain
MAUDE report 24832323 ↗MalfunctionApr 1, 2026Pacing Problem
IT WAS REPORTED BY THE PATIENT THAT THE IMPLANTABLE PULSE GENERATOR (IPG) IS NOT PACING THEIR HEART WHEN IT SHOULD AND THAT IT MAY NOT BE WORKING APPROPRIATELY. THE IPG REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24752316 ↗DeathMar 30, 2026Adverse Event Without Identified Device or Use Problem
IT WAS FURTHER REPORTED THAT THE PATIENT DIED DUE TO ASPIRATION PNEUMONIA ACUTE HYPOXIC RESPIRATORY FAILURE AND WAS NOT DEVICE RELATED.
Patient problems: Chest Pain; Insufficient Information
MAUDE report 24713790 ↗MalfunctionMar 24, 2026Pacing Problem
THE PATIENT REPORTED THAT THEIR APPLE WATCH SHOWS HEART RATE READINGS IN THE FORTIES. THE IMPLANTABLE PULSE GENERATOR (IPG) REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Bradycardia
MAUDE report 24680882 ↗InjuryMar 23, 2026Appropriate Device Problem Term/Code Not Available
IT WAS REPORTED THAT THE IPG WAS EXPLANTED AND THE RIGHT VENTRICULAR (RV) LEAD WAS CAPPED FOR AN UNKNOWN REASON. THE IPG AND LEAD WERE REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24659788 ↗InjuryMar 19, 2026Appropriate Device Problem Term/Code Not Available
IT WAS REPORTED THAT THE RIGHT ATRIAL (RA) LEAD EXHIBITED A FRACTURE, INTERMITTENT CAPTURE AND NOISE SENSING. THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED A FRACTURE, RISING PACING IMPEDANCE AND HIGH THRESHOLDS. THE RA AND RV LEADS WERE EXPLANTED AND WERE REPLACED WITH A LEADLESS IMPLANTABLE PULSE GENERATOR (IPG). THE IPG WAS EXPLANTED AND WAS REPLACED FOR UNKNOWN REASONS. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24637271 ↗MalfunctionFeb 13, 2026False Alarm
IT WAS REPORTED THAT THE IMPLANTABLE PULSE GENERATOR (IPG) EXHIBITED A FALSE LOW IMPEDANCE WARNING. THE IPG REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24332229 ↗InjuryJan 26, 2026Premature Discharge of Battery; Battery Problem
IT WAS REPORTED THAT THE IMPLANTABLE PULSE GENERATOR (IPG) WAS EXPLANTED AND REPLACED AS THE BATTERY HAD DEPLETED AFTER BEING IMPLANTED LESS THAN SIX YEARS. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24177096 ↗InjuryJan 9, 2026Premature Discharge of Battery
IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED HIGH THRESHOLDS AND THE IMPLANTABLE PULSE GENERATOR (IPG) EXHIBITED PREMATURE BATTERY DEPLETION. THE RV LEAD WAS CAPPED AND REPLACED. THE IPG WAS EXPLANTED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24019955 ↗InjuryJan 9, 2026Pacing Problem
IT WAS REPORTED THAT THE PATIENT EXPERIENCED HIGH BLOOD PRESSURE. THE PATIENT WAS ADMINISTERED MEDICATION AND THEN THE PATIENT'S HEART RATE DROPPED TO THIRTY SIX BEATS PER MINUTE. THE PATIENT WAS UNSURE OF THE IMPLANTABLE PULSE GENERATOR'S (IPG) FUNCTION. THE IPG REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Bradycardia
MAUDE report 24018867 ↗InjuryDec 19, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT EXPERIENCED ENTEROCOCCUS FAECALIS. THE IMPLANTABLE PULSE GENERATOR (IPG) SYSTEM WAS REMOVED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Bacterial Infection
MAUDE report 23847361 ↗MalfunctionDec 3, 2025False Alarm; False Alarm
IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED UNIPOLAR IMPEDANCE OUT OF RANGE. THE RV LEAD REMAINS IN USE. IT WAS FURTHER REPORTED THAT THE RV LEAD EXHIBITED LOW IMPEDANCE. IT WAS FURTHER REPORTED THAT THE RV LEAD EXHIBITED ANOTHER UNIPOLAR LEAD IMPEDANCE WARNING FOR LOW IMPEDANCE. IT WAS FURTHER REPORTED THAT THE IMPLANTABLE PULSE GENERATOR (IPG) ALSO EXHIBITED A FALSE LOW IMPEDANCE WARNING. THE IPG REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23704640 ↗InjurySep 19, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT DEVELOPED AN METHICILLIN-RESISTANT STAPHYLOCOCCUS AUREUS INFECTION ON THEIR LEFT LEG. IT WAS FURTHER REPORTED THAT THE PATIENT EXPERIENCED FEVER, PAIN, SEPSIS, BACTEREMIA AND VEGETATION WAS NOTED ON AORTIC AND MITRAL VALVES. THE SYSTEM WAS EXPLANTED AND NOT REPLACED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Bacteremia; Bacterial Infection; Fever; Medical device site infection; Sepsis; Unspecified Infection
MAUDE report 23093598 ↗InjuryAug 13, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT EXPERIENCED AN INFECTION. THE IMPLANTABLE PULSE GENERATOR (IPG) SYSTEM WAS REMOVED AND REPLACED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Unspecified Infection
MAUDE report 22792337 ↗InjuryJul 11, 2025Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
IT WAS REPORTED BY A PATIENT THAT THEY EXPERIENCED A "BRIEF BLACKOUT". THE IMPLANTABLE PULSE GENERATOR (IPG) REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Loss of consciousness
MAUDE report 22478209 ↗InjuryJun 23, 2025Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
IT WAS REPORTED THAT PATIENT EXPERIENCED ATRIAL TACHYCARDIA AND FATIGUE. IT WAS ALSO REPORTED THAT MEDICATION WAS ADMINISTERED. THE IMPLANTABLE PULSE GENERATOR (IPG) REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Fatigue; Tachycardia
MAUDE report 22307171 ↗MalfunctionJun 23, 2025False Alarm; False Alarm
IT WAS REPORTED THAT THE IMPLANTABLE PULSE GENERATOR (IPG) EXHIBITED A FALSE IMPEDANCE ALERT. IT WAS ALSO REPORTED THAT THE RIGHT ATRIAL (RA) LEAD EXHIBITED A LOW OUT OF RANGE IMPEDANCE. BOTH THE LEAD AND THE IPG REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22306974 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P980035. One submission often covers many models, so check the product and lot details in each record.
- Z-2128-2025 · Jun 17, 2025 · Open, ClassifiedMedtronic SmartLink software loaded on CareLink SmartSync Device Manager, Model Number 24967A with the following software components: 1. Azure Astra application, Software Model N
- Z-2127-2025 · Jun 17, 2025 · Open, ClassifiedMedtronic SmartLink Software loaded on SmartSync Patient Connector, Model Number 24967 with the following software components: 1. Azure Astra application, Software Model Number D
- Z-1924-2025 · Apr 29, 2025 · Open, ClassifiedAzure S DR MRI SureScan, Product number W3DR01
- Z-2507-2020 · Jun 4, 2020 · Open, ClassifiedAzure XT DR MRI, Model Numbers: a) W1DR01 and b) W2DR01
- Z-2508-2020 · Jun 4, 2020 · Open, ClassifiedAzure S DR MRI, Model Number W3DR01
- Z-2510-2020 · Jun 4, 2020 · Open, ClassifiedAzure S SR MRI, Model Number W3SR01
- Z-2509-2020 · Jun 4, 2020 · Open, ClassifiedAzure XT SR MRI, Model Numbers: a) W1SR01 and b) W2SR01
- Z-0806-2019 · Jan 17, 2019 · Open, ClassifiedMedtronic implantable pulse generator: ADAPTA, Dual chamber pacemaker (DDD): (a) Model Number ADD01 (b) Model Number ADDR01 (c) Model Number ADDR03 (d) Model Number ADDR06 (
- Z-0808-2019 · Jan 17, 2019 · Open, ClassifiedMedtronic implantable pulse generator: RELIA, Dual chamber pacemaker (VDD): (a) Model Number RED01 (b) Model Number REDR01 (c) Model Number REVDD01
- Z-0811-2019 · Jan 17, 2019 · Open, ClassifiedMedtronic implantable pulse generator: Versa, Dual chamber rate responsive pacemaker (DDDR), Model Number VEDR01
- Z-0807-2019 · Jan 17, 2019 · Open, ClassifiedMedtronic implantable pulse generator: ATTESTA L DR MRI SureScan, Dual chamber rate responsive pacemaker (DDDR): (a) Model Number ATDR01 (b) Model Number ATDRL1 (c) Model Numb
- Z-0809-2019 · Jan 17, 2019 · Open, ClassifiedMedtronic implantable pulse generator: SENSIA, Dual chamber pacemaker (DDD): (a) Model Number SED01 (b) Model Number SEDR01 (c) Model Number SEDRL1
- Z-0810-2019 · Jan 17, 2019 · Open, ClassifiedMedtronic implantable pulse generator: Sphera DR MRI SureScan, Dual chamber rate responsive pacemaker (DDDR): (a) Model Number SPDR01 (b) Model Number SPDRL1
- Z-2120-2011 · Apr 4, 2011 · TerminatedMedtronic, Kappa 600 KDR600,KDR601,KDR603,KDR606,KDR651,KDR653 The devices are implantable pulse generators (IPG) used to detect bradycardia events and provide pacing support. Wit
- Z-1440-2010 · Feb 11, 2010 · TerminatedMedtronic EnRhythm, P1501DR, Dual Chamber Rate Responsive Pacemaker with RapidRead Telemetry. The EnRhythm pacing system is an implantable medical device that monitors, detects,
…and 1 more.
Other Implantable pulse generator, pacemaker (non-CRT) devices
- Assurity MRI™ PM2272St. Jude Medical, Inc. · Implantable pulse generator, pacemaker (non-CRT)1 recall264 deaths16,996 reports
- ACCOLADE™ MRI EL DR L331Boston Scientific Corporation · Implantable pulse generator, pacemaker (non-CRT)2 recalls22 deaths7,984 reports
- Azure™ XT DR MRI SureScan™ W1DR01Medtronic, Inc. · Implantable pulse generator, pacemaker (non-CRT)187 deaths7,655 reports
- ACCOLADE™ MRI DR L311Boston Scientific Corporation · Implantable pulse generator, pacemaker (non-CRT)2 recalls59 deaths7,283 reports
- Azure™ XT DR MRI SureScan™ W1DR01Medtronic, Inc. · Implantable pulse generator, pacemaker (non-CRT)107 deaths5,971 reports
- ACCOLADE™ DR L301Boston Scientific Corporation · Implantable pulse generator, pacemaker (non-CRT)2 recalls6 deaths2,513 reports
- ACCOLADE™ EL DR L321Boston Scientific Corporation · Implantable pulse generator, pacemaker (non-CRT)2 recalls2 deaths1,906 reports
- ACUITY™ X4 Spiral S 4674Boston Scientific Corporation · Implantable pulse generator, pacemaker (non-CRT)16 deaths1,975 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page