Claria MRI™ Quad CRT-D SureScan™ DTMA1Q1 (UDI 00643169705760)Recalls & reported problems

Medtronic, Inc. · CRTD DTMA1Q1 CLARIA MRI QUAD US DF1 · Class 3 · Implant

All models of Claria MRI Quad CRT-D SureScan (8)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Quick summary

This Medtronic Claria MRI CRT-D is an implanted defibrillator that delivers shocks and pacing to keep the heart rhythm steady. The 51 reports mostly describe the device not sensing rhythms or delivering therapy as expected, giving shocks when none were needed, and batteries draining sooner than expected. 28 reports describe injuries and no deaths were reported. Three recalls name this device; the one started in February 2021 remains open, over batteries reaching end of service earlier than expected.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
51
Deaths reported
0
Injuries reported
28
Recalls naming it
3

Summary

The FDA's MAUDE database contains 51 adverse event reports that list this exact device (DI 00643169705760), received between Jun 8, 2017 and Sep 6, 2024 — classified as 28 injuries, 23 malfunctions.

The most frequently reported specific device problem is “Device Sensing Problem” (8 reports).

3 FDA recall records name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Feb 3, 2021Class IOpen, Classified

    A small percentage of implanted cardiac devices, from a well-defined subset, may experience a shortened Recommended Replacement Time (RRT) to End of Service (EOS) interval following an earlier-than-expected RRT observation

    Z-1306-2021 · Root cause: Device Design · Recall details · FDA record ↗

  2. Dec 19, 2017Class ITerminated

    Possible prevention of high and low voltage therapy in Medtronic Implantable Cardioverter Defibrillators (ICDs) and Cardiac Resynchronization Therapy Defibrillator (CRT-D).

    Z-0586-2018 · Root cause: Process design · Recall details · FDA record ↗

  3. Dec 9, 2016Class IITerminated

    During internal testing conducted as part of next generation product development, it was discovered that the AdaptivCRT (aCRT) feature of Amplia MRI and Claria MRI CRT -D devices may appear to be enabled when it is not active.

    Z-0962-2017 · Root cause: Software Design Change · Recall details · FDA record ↗

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem10
  • Device Sensing Problem8
  • Electrical /Electronic Property Problem8
  • Inappropriate/Inadequate Shock/Stimulation6
  • Premature Discharge of Battery4
  • Battery Problem2
  • Failure to Deliver Shock/Stimulation2
  • Inappropriate or Unexpected Reset2

Patient problems

  • No Known Impact Or Consequence To Patient10
  • No Patient Involvement9
  • Shock from Patient Lead(s)6
  • Unspecified Infection6
  • No Consequences Or Impact To Patient5
  • No Clinical Signs, Symptoms or Conditions4
  • Erosion2
  • Hematoma2

Recent adverse event reports

The 25 most recent of 51 reports, in the reporter's own words as published by the FDA.

  • InjurySep 6, 2024Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem; Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem

    IT WAS REPORTED THAT THE PATIENT WAS INAPPROPRIATELY SHOCKED BY THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) FOR ATRIAL FIBRILLATION (AF) WITH RAPID VENTRICULAR RESPONSE. REPROGRAMMING WAS PERFORMED AND ANTIARRHYTHMIC MEDICATION WAS ADMINISTERED. THE CRT-D REMAINS IN USE. THE PATIENT IS A PARTICIPANT IN A CLINICAL STUDY. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Shock from Patient Lead(s)

    MAUDE report 20155264 ↗
  • MalfunctionAug 20, 2024Pacing Problem; Pacing Problem

    IT WAS LATER REPORTED THAT THE CRT-D WAS FUNCTIONING PROPERLY. THE REPORTED BRADYCARDIA WAS ACTUALLY PREMATURE VENTRICULAR CONTRACTIONS (PVC) THAT WERE NOT BEING COUNTED. THERE WAS NO TRUE BRADYCARDIA AND PACING BELOW THE PROGRAMMED RATE WAS NOT CONFIRMED. THE REPORTED WEAKNESS WAS ALSO NOTED TO BE UNRELATED TO PRODUCT PERFORMANCE.

    Patient problems: Bradycardia

    MAUDE report 20008296 ↗
  • MalfunctionApr 22, 2024Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT THE PATIENT PRESENTED TO THE EMERGENCY DEPARTMENT WITH ATRIAL FIBRILLATION (AF) AND WAS CONCERNED IF THE DEVICE WAS WORKING PROPERLY. REVIEW OF DEVICE DATA INDICATED SUSPECTED UNDERSENSING ON THE RIGHT ATRIAL (RA) LEAD. THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) AND RA LEAD REMAIN IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Atrial Fibrillation

    MAUDE report 19160267 ↗
  • InjuryMar 28, 2024Failure to Deliver Shock/Stimulation; Device Sensing Problem; Failure to Deliver Shock/Stimulation; Device Sensing Problem

    IT WAS REPORTED THAT THE PATIENT WAS SYMPTOMATIC. UPON REVIEW IT WAS NOTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) INAPPROPRIATELY WITHHELD THERAPY FOR VENTRICULAR TACHYCARDIA (VT) EPISODES WHICH WERE CLASSIFIED AS SUPRA VENTRICULAR TACHYCARDIA (SVT) VIA THE DEVICE FEATURE THAT COMPARES THE PATIENT¿S CURRENT QRS WAVEFORM TO A COLLECTED AND STORED TEMPLATE OF THE PATIENT¿S QRS WAVEFORM DURING SINUS RHYTHM. IT WAS ALSO NOTED THAT THE PHYSICIAN THOUGHT THE DEVICE WAS CLASSIFYING EPISODES AS TERMINATED WHEN THE EVENTS DID NOT APPEAR TO BE TRULY TERMINATED CLINICALLY. THE DEVICE IS STILL IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT. IT WAS ADDITIONALLY REPORTED THAT THE DEVICE FEATURE WAS PROGRAMMED OFF.

    Patient problems: Tachycardia

    MAUDE report 19000004 ↗
  • InjuryDec 19, 2023Misconnection; Misconnection

    IT WAS REPORTED THAT DURING THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) GENERATOR CHANGE OUT PROCEDURE, A CONNECTOR HEADER ISSUE OCCURRED AS THE LEFT VENTRICULAR (LV) LEAD COULD NOT BE REMOVED. A BONE CUTTER WAS USED TO REMOVE THE HEADER OF DEVICE AND GET THE LV LEAD OUT. THE CRT-D WAS REMOVED, AND REPLACED. THE LV LEAD REMAINS IN USE WITH THE NEW DEVICE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18358016 ↗
  • InjuryMar 8, 2023Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem; Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem

    IT WAS REPORTED THAT THE PATIENT RECEIVED POSSIBLE INAPPROPRIATE HIGH VOLTAGE THERAPY FOR SUPRA VENTRICULAR TACHYCARDIA (SVT) THAT WAS DETECTED AS A VENTRICULAR TACHYCARDIA (VT). THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Shock from Patient Lead(s)

    MAUDE report 16505594 ↗
  • InjuryMar 28, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) WAS EXPLANTED DUE TO AN INFECTION. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Unspecified Infection

    MAUDE report 13930633 ↗
  • InjuryMar 24, 2022Premature Discharge of Battery; Premature Discharge of Battery

    IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) EXHIBITED PREMATURE BATTERY DEPLETION. IT WAS ALSO NOTED THAT THE LEFT VENTRICULAR (LV) LEAD EXHIBITED HIGH THRESHOLDS. THE DEVICE WAS EXPLANTED AND REPLACED. THE LEAD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13892281 ↗
  • InjuryJul 29, 2021Failure to Deliver Shock/Stimulation; Device Sensing Problem; Failure to Deliver Shock/Stimulation; Device Sensing Problem

    IT WAS REPORTED THAT THE PATIENT EXPERIENCED SYNCOPE DURING AN EPISODE OF DOUBLE TACHYCARDIA. THERE WAS A DELAY OF THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) DETECTING AND PROVIDING HIGH VOLTAGE THERAPY FOR THE TACHYCARDIA BECAUSE A DEVICE FEATURE CLASSIFIED THE EPISODE AS SUPRA VENTRICULAR TACHYCARDIA (SVT). THE CRT-D DID PROVIDE APPROPRIATE THERAPY AFTER IT RECOGNIZED THE TACHYCARDIA. THE CRT-D WAS REPROGRAMMED AND REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Syncope/Fainting; Tachycardia

    MAUDE report 12249985 ↗
  • InjuryJul 27, 2021Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem; Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem

    IT WAS REPORTED THAT THERE WAS A SUSPECTED INAPPROPRIATE SHOCK FOR ATRIAL FIBRILLATION (AF) WITH RAPID VENTRICULAR RESPONSE THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) CLASSIFIED AS VENTRICULAR FIBRILLATION (VF). THE DEVICE REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Shock from Patient Lead(s)

    MAUDE report 12232430 ↗
  • MalfunctionMar 31, 2021Premature Discharge of Battery; Premature Discharge of Battery

    IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) IS NOT LASTING AS LONG AS EXPECTED. IT WAS NOTED THAT THE HEALTHCARE PROFESSIONAL SUSPECTED ABNORMAL DEVICE FUNCTION. THE DEVICE REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11596328 ↗
  • MalfunctionFeb 8, 2021Signal Artifact/Noise; Over-Sensing; Signal Artifact/Noise; Over-Sensing

    THE PATIENT IS A PARTICIPANT IN A CLINICAL STUDY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11293923 ↗
  • InjuryOct 16, 2020Premature Discharge of Battery; Premature Discharge of Battery

    IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) EXHIBITED PREMATURE BATTERY DEPLETION WITH LESS THAN THREE YEARS OF SERVICE LIFE. THE DEVICE WAS EXPLANTED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10693451 ↗
  • InjuryOct 1, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SYSTEM WAS REMOVED DUE TO INFECTION. A NEW SYSTEM WAS IMPLANTED A FEW DAYS LATER. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Unspecified Infection

    MAUDE report 10618136 ↗
  • InjurySep 30, 2020Reset Problem; Reset Problem

    IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) ALERTED FOR AN ELECTRICAL RESET DURING INTERROGATION. SOFTWARE WAS SUCCESSFULLY UPLOADED AND THE DEVICE IS STILL IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10606911 ↗
  • InjurySep 17, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SYSTEM WAS EXPLANTED DUE TO INFECTION. A TEMPORARY PACING LEAD WAS PLACED WITH AN EXTERNAL DEVICE. WHEN THE PATIENT IS FULLY HEALED, A REPLACEMENT SYSTEM WILL BE IMPLANTED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Unspecified Infection

    MAUDE report 10549700 ↗
  • InjurySep 10, 2020Inappropriate or Unexpected Reset; Inappropriate or Unexpected Reset

    IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) EXHIBITED A POWER ON RESET (POR) DURING INTERROGATION DUE TO A FIRMWARE DOWNLOAD ERROR. THE CRT-D WAS RE-INTERROGATED AND THE RESET WAS CLEARED. THE CRT-D REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10514309 ↗
  • InjurySep 8, 2020Inappropriate or Unexpected Reset; Inappropriate or Unexpected Reset

    IT WAS REPORTED THAT THE DEVICE EXPERIENCED A PARTIAL ELECTRICAL RESET. THE DEVICE WAS REPROGRAMMED AND REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10504660 ↗
  • InjuryJul 22, 2020Reset Problem; Reset Problem

    IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) EXPERIENCED AN ELECTRICAL RESET DUE TO A SOFTWARE GLITCH. THE DEVICE WAS RE-INTERROGATED FOR DIAGNOSTIC TESTING AND REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10309786 ↗
  • InjuryJun 23, 2020Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem; Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem

    IT WAS REPORTED THAT THE PATIENT POSSIBLY RECEIVED AN INAPPROPRIATE SHOCK FOR ATRIAL FIBRILLATION (AF) WITH RAPID VENTRICULAR RESPONSE THAT THE DEVICE CLASSIFIED AS VENTRICULAR FIBRILLATION (VF). THE DEVICE REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Shock from Patient Lead(s)

    MAUDE report 10185087 ↗
  • MalfunctionJan 30, 2020Premature Discharge of Battery; Premature Discharge of Battery

    IT WAS REPORTED THAT THERE WAS CONCERNS OF EARLY BATTERY DEPLETION ON THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D). FOLLOW UP CONCLUDED THAT NO INTERVENTION WAS DONE. THE DEVICE REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9649214 ↗
  • InjuryNov 20, 2019Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem; Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem

    IT WAS REPORTED THAT PATIENT RECEIVED AN INAPPROPRIATE SHOCK FOR SUPRA VENTRICULAR TACHYCARDIA (SVT) THAT THE DEVICE CLASSIFIED AS VENTRICULAR TACHYCARDIA (VT). THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Shock from Patient Lead(s)

    MAUDE report 9348635 ↗
  • InjurySep 25, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT'S SYSTEM WAS REMOVED DUE TO INFECTION. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Unspecified Infection

    MAUDE report 9120353 ↗
  • InjuryJul 26, 2019Signal Artifact/Noise; Electromagnetic Interference; Inappropriate/Inadequate Shock/Stimulation; Signal Artifact/Noise; Electromagnetic Interference; Inappropriate/Inadequate Shock/Stimulation

    IT WAS REPORTED THAT THE PATIENT RECEIVED AN INAPPROPRIATE SHOCK DUE TO ELECTROMAGNETIC INTERFERENCE FROM AN IMPROPERLY GROUNDED SWIMMING POOL. FOLLOW UP CONCLUDED NO INTERVENTION HAS BEEN PERFORMED. THE DEVICE REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Shock from Patient Lead(s)

    MAUDE report 8831091 ↗
  • MalfunctionDec 17, 2018Data Problem; Data Problem

    IT WAS REPORTED THAT THE DEVICE LONGEVITY IS SHORTER THAN THE PATIENT'S AND DOCTOR'S EXPECTATIONS. THE DEVICE REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8170244 ↗

Other Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D) devices

All Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page