Skip to content

TRANSLACE™ Spinal Tethering System 8205300 (UDI 00643169726918)Recalls & reported problems

Medtronic Sofamor Danek, Inc. · CONNECTOR 8205300 CONNECTOR · Class 2 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00643169726918), received between Apr 18, 2022 and Apr 18, 2022 — classified as 1 injury.

The most frequently reported specific device problem is “Expulsion” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Expulsion1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 18, 2022Expulsion; Expulsion

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING REVISION SURGERY. INITIAL SURGERY OF TH4-L1 POSTERIOR SPINE FIXATION WAS PERFORMED ON (B)(6) 2018. IT WAS REPORTED THAT THERE WAS  IMPLANT PROTRUSION ON THE DORSAL SIDE. THE IMPLANT IS REMOVED AND THE PATIENT HAD RECOVERED. THERE WAS NO PATIENT SYMPTOM REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14133399 ↗

FDA clearance and classification

Cleared through 510(k) K163181 on May 16, 2017 (decision: Substantially Equivalent). Submitted by Medtronic Sofamor Danek USA, Inc. as “TRANSLACE™ Spinal Tethering System”. The FDA review took 183 days. FDA record ↗

The FDA regulates product code OWI (bone fixation cerclage, sublaminar) under 21 CFR 888.3010 as a Class II device. 21 CFR 888.3010 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

FDA definition of this device type: Acts as a bone anchor for temporary stabilization, or used in conjunction with other medical implants of similar metals when wiring is needed, during development of a spinal fusion.

Common questions about the TRANSLACE™ Spinal Tethering System 8205300

Has the TRANSLACE™ Spinal Tethering System 8205300 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00643169726918), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the TRANSLACE™ Spinal Tethering System 8205300?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Apr 18, 2022. That report lists device problem “Expulsion” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the TRANSLACE™ Spinal Tethering System 8205300?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the TRANSLACE™ Spinal Tethering System 8205300 FDA approved?

It was cleared through 510(k) K163181 on May 16, 2017. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the TRANSLACE™ Spinal Tethering System 8205300 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the TRANSLACE™ Spinal Tethering System 8205300, and is it still sold?

The FDA's device database lists Medtronic Sofamor Danek, Inc. as the company responsible for it (brand TRANSLACE™ Spinal Tethering System, model 8205300). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Bone fixation cerclage, sublaminar devices

All Bone fixation cerclage, sublaminar devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page