Skip to content

Visi-Pro™ PXB35-10-27-135Recalls & reported problems

Covidien LP · PXB35-10-27-135 STENT VISI PRO 035 V01 · Class 2 · Implant

All models of Visi-Pro (66)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00643169788022), received between Jan 3, 2020 and Jan 3, 2020 — classified as 1 injury.

The most frequently reported specific device problem is “Device Damaged by Another Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Device Damaged by Another Device1
  • Device Dislodged or Dislocated1
  • Entrapment of Device1
  • Physical Resistance/Sticking1
  • Positioning Problem1

Patient problems

  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 3, 2020Entrapment of Device; Device Damaged by Another Device; Device Dislodged or Dislocated; Positioning Problem; Physical Resistance/Sticking; Entrapment of Device; Device Damaged by Another Device; Device Dislodged or Dislocated; Positioning Problem; Physical Resistance/Sticking

    PHYSICIAN USED TWO VISIPRO STENTS DURING TREATMENT OF A 50MM CALCIFIED LESION IN THE PATIENT¿S RIGHT PROXIMAL COMMON ILIAC ARTERY WITH REPORTED DIAMETER 10MM. SEVERE VESSEL CALCIFICATION IS REPORTED. LESION EXHIBITED 85% STENOSIS. A NON-MEDTRONIC 7FR SHEATH AND NON-MEDTRONIC GUIDEWIRE WERE USED. IFU WAS FOLLOWED. NO DAMAGE TO DEVICE PACKAGING WAS NOTED PRIOR TO USE. NO ISSUES WERE NOTED WHEN REMOVING HE VISIPRO STENTS FROM THE PACKAGING. LESION PRE-DILATION WAS PERFORMED USING A PTA BALLOON (7X40MM). THE DEVICES WERE NOT PASSED THROUGH A PREVIOUSLY DEPLOYED STENT. RESISTANCE IS REPORTED TO HAVE BEEN ENCOUNTERED WHEN ADVANCING. IT IS REPORTED THAT THE FIRST STENT DISLODGED PRIOR TO DEPLOYMENT AND THE SECOND STENT SLIPPED OFF THE BALLOON WHEN ATTEMPTING TO REPOSITION. THE SECOND STENT WAS SNARED IN AORTA AND BROUGHT TO THE RIGHT ILIAC ARTERY AND DEPLOYED. THE STENT WAS CRUSHED USING A DELIVERY BALLOON. A NON-MEDTRONIC COVERED STENT WAS THEN USED TO COVER BOTH STENTS. NO FURTHER INJURY REPORTED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9543885 ↗

Other Stents, drains and dilators for the biliary ducts devices

All Stents, drains and dilators for the biliary ducts devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page