Abre™ AB9U12060090Recalls & reported problems

Medtronic, Inc. · STENT AB9U12060090 ABRE V01 · Class 3 · Implant

All models of Abre (26)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
4
Deaths reported
0
Injuries reported
3
Recalls naming it
1

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00643169796225), received between Jul 9, 2021 and Jan 22, 2026 — classified as 3 injuries, 1 malfunction.

The most frequently reported specific device problem is “Migration or Expulsion of Device” (2 reports).

1 FDA recall record name this device's identifier, 1 still open.

2 other recalls cover devices cleared under the same FDA submission (P200026); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Dec 4, 2025Open, Classified

    Stents may be impacted by a Nitinol anomaly which causes a reduced stent diameter when deployed and corresponding reduced radial force. Issue may result in stent migration.

    Z-1098-2026 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

Most reported problems

Device problems

  • Migration or Expulsion of Device2
  • Adverse Event Without Identified Device or Use Problem1
  • Device Dislodged or Dislocated1
  • Use of Device Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Chest Pain1
  • Insufficient Information1
  • Obstruction/Occlusion1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 22, 2026Use of Device Problem

    IT WAS REPORTED THAT AN ABRE STENT THAT EXPIRED ON 04-JAN-2026 WAS IMPLANTED IN A PATIENT ON (B)(6) 2026. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24143527 ↗
  • InjuryNov 6, 2025Migration or Expulsion of Device; Device Dislodged or Dislocated; Migration or Expulsion of Device; Device Dislodged or Dislocated

    IT WAS REPORTED THAT DURING A PROCEDURE TO TREAT SUPERIOR VENA CAVA STENOSIS DUE TO MALIGNANT OBSTRUCTION, THE STENT ABRE 12MM WAS DEPLOYED FROM INTERNAL JUGULAR ACCESS AFTER VESSEL MEASUREMENT WITH INTRAVASCULAR ULTRASOUND AND LOCATION CONFIRMATION WITH FLUOROSCOPY (IVUS MEASURED 9.5MM). THE VESSEL EXHIBITED 90% LESION STENOSIS, A LESION LENGTH OF 50MM, MODERATE CALCIFICATION, AND MINIMAL TORTUOSITY, WITH A REFERENCE VESSEL DIAMETER OF 9.6MM. UPON DEPLOYMENT, THE STENT IMMEDIATELY MIGRATED INTO THE RIGHT ATRIUM AND DID NOT COVER THE LESION. THE STENT WAS SUCCESSFULLY SNARED (GOSSENECK SNARE) AND REMOVED FROM THE BODY VIA FEMORAL VEIN ACCESS, AND INSPECTION CONFIRMED IT WAS FULLY INTACT. THE VESSEL WAS PRE-DILATED WITH A NON-MEDTRONIC (10MM CONQUEST) BALLOON AND POST-DILATED WITH A NON-MEDTRONIC (12MM CONQUEST) BALLOON. A NEW 14X60MM ABRE STENT WAS SUBSEQUENTLY PLACED FROM FEMORAL VEIN ACCESS WITHOUT ISSUE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23488068 ↗
  • InjuryApr 3, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    TWO ABRE STENTS SELF-EXPANDING WERE IMPLANTED FOR THE TREATMENT OF A FIBROUS LESION IN THE LEFT COMMON ILIAC VEIN AND LEFT EXTERNAL ILIAC VEIN. THERE WAS MILD TORTUOSITY AND NO CALCIFICATION. THE DEVICES WERE PREPPED AS PER THE IFU WITH NO ISSUES IDENTIFIED. THE LESION WAS PRE-DILATED. THE PROCEDURE WAS COMPLETED WITH NO ISSUES MENTIONED. DURING A FOLLOW UP VISIT THE STENTS WERE NOTED TO BE OCCLUDED. REINTERVENTION ON THIS PATIENT WITH THE DOCTOR ON (B)(6) 2023. DURING THE CASE, THE STENTS WERE REOPENED THE BY REMOVING THE PRESENT CLOT WITH ASPIRATIONAL THROMBECTOMY AND USING A HIGH-PRESSURE BALLOON. THE STENTS WERE RE-EVALUATED THAT WERE ORIGINALLY PLACED, AND THE PHYSICIAN HAD THE FOLLOWING CONCLUSIONS: UNSURE ABOUT WHY THE STENTS WENT DOWN. STENTS APPEARED TO BE PROPERLY SIZED ACCORDING TO IVUS ¿ NO SPACE BETWEEN VESSEL WALL AND STENT, NO ¿STEP¿ INTO NATIVE VESSEL WHICH WOULD MEAN AN OVERSIZING. AFTER CLEARING STENTS OF CLOT AND REOPENING, NO COLLATERAL VESSELS APPEARED ON VENOGRAM. THIS LED THE DOCTOR TO BELIEVE THAT THERE ARE NO VESSELS THAT ARE STEALING FLOW FROM THE ILIAC VEINS AFTER THE CASE NO CLINICAL REASON COULD BE CONFIRMED WHY THE STENTS SHUT DOWN AT THAT TIME. PHYSIC

    Patient problems: Obstruction/Occlusion

    MAUDE report 16662501 ↗
  • InjuryJul 9, 2021Migration or Expulsion of Device; Migration or Expulsion of Device

    PHYSICIAN USED AN ABRE SELF-EXPANDING STENT WITH A 9FR SHEATH DURING TREATMENT OF PROXIMAL LEFT COMMON ILIAC VEIN COMPRESSION, MAY-THURNER SYNDROME. MODERATE VESSEL TORTUOSTY REPORTED. HEALTH TISSUE WAS MEASURING 12 MM ON BOTH DISTAL AND PROXIMAL AREAS, WHERE AREA OF COMPRESSION HAD AVERAGE OF 8.5 MM. THERE WAS NO DAMAGE NOTED TO PACKAGING (I.E. SHELF CARTON, HOOP/TRAY). THERE WERE NO ISSUES NOTED WHEN REMOVING THE DEVICE FROM THE HOOP/TRAY. THE DEVICE AS PREPPED AS PER IFU WITHOUT ISSUE. THE DEVICE WAS NOT PASSED THROUGH A PREVIOUSLY DEPLOYED STENT. NO RESISTANCE NOTED DURING ADVANCEMENT. THE DEVICE WAS IMPLANTED WITHOUT ANY ISSUES. PRE-DILATION WAS NOT PERFORMED BUT POST-DILATION WAS PERFORMED WITH 12 MM NON-MEDTRONIC BALLOON. NO DEVIATIONS NOTED DURING THE PROCEDURE. ONE DAY POST PROCEDURE THE PATIENT EXPERIENCED SEVERE CHEST PAINS AND HEART BURN. THE PATIENT IMMEDIATELY ATTENDED THE EMERGENCY ROOM AND ULTRASOUND REVEALED THE STENT HAD MIGRATED TO THE HEART. THE PATIENT WAS SENT TO IR TO HAVE STENT RETRIEVED. STENT RETRIEVAL WAS SUCCESSFUL. THE STENT WAS STUCK IN BETWEEN RIGHT ATRIUM AND RIGHT VENTRICLE IN THE TRICUSPID VALVE. PATIENT WILL RETURN FOR FOLLOW-UP TO SEE IF ANY DAMA

    Patient problems: Chest Pain

    MAUDE report 12141232 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under P200026. One submission often covers many models, so check the product and lot details in each record.

  • Z-0464-2022 · Nov 19, 2021 · Terminated
    Instructions for Use for all model numbers of the Medtronic Abre Venous Self-Expanding Stent System.
  • Z-1532-2021 · Mar 16, 2021 · Terminated
    Medtronic Abre Venous Self-expanding Sent System, Catalog number REF AB9U16080090 - Product Usage: intended for use in the iliofemoral veins for the treatment of symptomatic venous

Other Stent, iliac vein devices

All Stent, iliac vein devices →