CapSure®SP Novus 4092-52Recalls & reported problems
Medtronic, Inc. · LEAD 4092-52 CAPSURE SP NOVUS US · Class 3 · Implant
All models of CapSureSP Novus (14)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
Quick summary
This Medtronic CapSure SP Novus pacemaker lead connects a pacemaker to the heart. Many of the 304 reports describe the lead needing stronger pulses to pace the heart, misreading heart signals, or failing to trigger a beat, and some mention infections that led to removal of the device. The reports include 1 death and 172 injuries, and no recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 307
- Deaths reported
- 1
- Injuries reported
- 174
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 307 adverse event reports that list this exact device (DI 00681490110655), received between Feb 9, 2017 and Sep 16, 2026 — classified as 1 death, 174 injuries, 132 malfunctions.
The most frequently reported specific device problem is “High Capture Threshold” (92 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- High Capture Threshold92
- Over-Sensing62
- Adverse Event Without Identified Device or Use Problem49
- Failure to Capture36
- Under-Sensing32
- High impedance28
- Capturing Problem21
- Impedance Problem21
Patient problems
- No Clinical Signs, Symptoms or Conditions110
- No Known Impact Or Consequence To Patient85
- Unspecified Infection36
- Dizziness11
- No Consequences Or Impact To Patient10
- Bradycardia9
- Chest Pain9
- Syncope8
Recent adverse event reports
The 25 most recent of 307 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 16, 2026Failure to Capture; High Capture Threshold
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50794928 ↗InjurySep 11, 2026Signal Artifact/Noise; Failure to Capture; Electrical /Electronic Property Problem; Fracture; High impedance; Over-Sensing; Pacing Problem
It was reported that the Right Ventricular (RV) lead exhibited loss of capture, a lead fracture, oversensing resulting in inhibition of pacing and misclassification of episode type, noise, a polarity switch and high impedance. The RV lead was capped and was replaced by a leadless Implantable Pulse Generator (IPG). No patient complications have been reported as a result of this event.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50729766 ↗InjuryAug 26, 2026Adverse Event Without Identified Device or Use Problem
It was reported that the Implantable Pulse Generator (IPG) system was explanted due to an infection. No further patient complications have been reported as a result of this event.
Patient problems: Unspecified Infection
MAUDE report 50451158 ↗MalfunctionAug 18, 2026High impedance
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50296160 ↗InjuryAug 4, 2026Fracture; High impedance
It was reported that the Right Ventricular (RV) lead had a suspected fracture and exhibited high impedance. The RV lead was capped and replaced. No patient complications have been reported as a result of this event.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50128652 ↗MalfunctionJun 11, 2026Under-Sensing
IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED UNDERSENSING. THE RV LEAD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25467864 ↗MalfunctionMay 15, 2026High Capture Threshold
IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED HIGH THRESHOLDS. THE LEAD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25181085 ↗MalfunctionMay 13, 2026Under-Sensing
IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD LEAD EXHIBITED UNDERSENSING ON STORED ELECTROGRAMS (EGM). THE RV LEAD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25158453 ↗MalfunctionMay 7, 2026Pacing Problem; Under-Sensing
IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED UNDER SENSING, RESULTING IN INAPPROPRIATE PACING. THE RV LEAD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25111450 ↗MalfunctionApr 30, 2026Over-Sensing
IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED OVERSENSING AND RIGHT ATRIAL (RA) LEAD EXHIBITED NOISE, OVERSENSING, ELEVATED THRESHOLDS AND THE ATRIAL LEAD POSITION CHECK FAILED. THE LEADS REMAIN IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25042071 ↗MalfunctionApr 24, 2026Capturing Problem; High Capture Threshold
IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED A GRADUAL INCREASE IN THRESHOLDS AND HIGH THRESHOLDS. THE RV LEAD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24977104 ↗MalfunctionApr 17, 2026Under-Sensing
IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED UNDERSENSING. IT WAS ALSO REPORTED THAT THE IMPLANTABLE PULSE GENERATOR (IPG) EXHIBITED A DIAGNOSTIC RESET. ADDITIONALLY, IT WAS REPORTED THAT THE RA LEAD EXHIBITED LOW IMPEDANCE. BOTH LEADS AND IPG REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24908056 ↗InjuryApr 7, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT EXPERIENCED POCKET INFECTION. THE IMPLANTABLE PULSE GENERATOR (IPG) WAS EXPLANTED AND REPLACED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Medical device site infection
MAUDE report 24797434 ↗MalfunctionMar 30, 2026Over-Sensing; High Capture Threshold
IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED OVER SENSING RESULTING IN MISCLASSIFICATION OF EPISODE TYPE. IT WAS ALSO REPORTED THAT THE RV LEAD DISPLAYED HIGH NUMBER OF SHORT V-V INTERVALS AND CHRONIC HIGH THRESHOLDS. THE RV LEAD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24727803 ↗InjuryMar 9, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT EXPERIENCED AN INFECTION AND EROSION AT THE LEFT PACEMAKER IMPLANT SITE. THE IMPLANTABLE PULSE GENERATOR (IPG) SYSTEM WAS EXPLANTED AND REPLACED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Erosion; Medical device site infection
MAUDE report 24543307 ↗MalfunctionFeb 12, 2026High Capture Threshold
IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED CHRONIC HIGH THRESHOLDS. THE RV LEAD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24321355 ↗InjuryFeb 3, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT EXPERIENCED AN INFECTION OF UNKNOWN ORIGIN. IT WAS ALSO NOTED THAT THE PATIENT EXPERIENCED A FEVER. THE IMPLANTABLE PULSE GENERATOR (IPG) SYSTEM WAS EXPLANTED AND REPLACED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A R ESULT OF THIS EVENT.
Patient problems: Fever; Unspecified Infection
MAUDE report 24247459 ↗InjuryJan 7, 2026Fracture; Difficult to Remove
IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED A FRACTURE. THE RV LEAD WAS PARTIALLY EXPLANTED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23988004 ↗InjuryDec 30, 2025Failure to Capture; Fracture; High impedance; High Capture Threshold; Failure to Capture; Fracture; High impedance; High Capture Threshold
IT WAS FURTHER REPORTED THAT WHEN THE PHYSICIAN REMOVED THE IPG FROM THE DEVICE POCKET, IMPEDANCE ROSE HIGH OUT OF RANGE AND THE RV LEAD WAS UNABLE TO MAINTAIN CAPTURE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23922472 ↗MalfunctionDec 4, 2025Over-Sensing; Low impedance; Over-Sensing; Low impedance
IT WAS REPORTED THAT THE RIGHT ATRIAL (RA) LEAD EXHIBITED RISING AND HIGH THRESHOLDS, RISING AND HIGH IMPEDANCE AND NOISE. A FRACTURE WAS SUSPECTED. THE RA LEAD WAS CAPPED AND REPLACED AND REMAINS IN THE PATIENT. IT WAS ALSO REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED LOW IMPEDANCE AND OVERSENSING. THE RV LEAD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23719966 ↗MalfunctionSep 5, 2025High Capture Threshold; High Capture Threshold
IT WAS REPORTED THAT THE RIGHT ATRIAL (RA) LEAD EXHIBITED CHRONIC OVERSENSING DETECTED AS ATRIAL TACHYCARDIA/ATRIAL FIBRILLATION (AT/AF) AND CHRONIC HIGH THRESHOLDS. THESE SHOWED AS NON-PHYSIOLOGIC RATES AND MORPHOLOGIES. THE RIGHT VENTRICULAR (RV) LEAD ALSO EXHIBITED CHRONIC HIGH THRESHOLDS. THE RA AND RV LEADS REMAIN IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22976772 ↗InjurySep 3, 2025Pacing Problem; Adverse Event Without Identified Device or Use Problem; Pacing Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT DEVELOPED AN INFECTION. THE IMPLANTABLE PULSE GENERATOR (IPG) SYSTEM WAS EXPLANTED DUE TO TO POCKET INFECTION AND LOW PACING. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Medical device site infection
MAUDE report 22951112 ↗MalfunctionJul 18, 2025Pacing Problem; Under-Sensing; Pacing Problem; Under-Sensing
IT WAS REPORTED THAT THE DEVICE APPEARS TO BE UNDER SENSING ON THE RIGHT VENTRICULAR (RV) LEAD ON SOME ELECTROGRAMS (EGM) RESULTING IN VENTRICULAR PACING AT TIMES. THE LEAD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22541415 ↗MalfunctionJul 7, 2025Pacing Problem; Under-Sensing; Pacing Problem; Under-Sensing
IT WAS REPORTED THAT THE PATIENT EXPERIENCED LETHARGY. IT WAS FURTHER REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED UNDERSENSING AND INAPPROPRIATE PACING. THE LEAD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Fatigue
MAUDE report 22409883 ↗InjuryJun 25, 2025Signal Artifact/Noise; Signal Artifact/Noise
IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED NOISE. THE LEAD WAS CAPPED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22329915 ↗
Other permanent pacemaker Electrode devices
- CapSureFix Novus MRI™ SureScan® 5076-45Medtronic, Inc. · permanent pacemaker Electrode136 deaths16,004 reports
- CapSureFix Novus MRI™ SureScan® 5076-58Medtronic, Inc. · permanent pacemaker Electrode124 deaths8,405 reports
- Capsurefix® Novus 5076-45Medtronic, Inc. · permanent pacemaker Electrode85 deaths7,050 reports
- CapSureFix Novus MRI™ SureScan™ 407652Medtronic, Inc. · permanent pacemaker Electrode69 deaths6,097 reports
- SelectSecure™ MRI SureScan™ 383069Medtronic, Inc. · permanent pacemaker Electrode56 deaths4,850 reports
- Sprint Quattro Secure® 694765Medtronic, Inc. · permanent pacemaker Electrode73 deaths3,852 reports
- Attain Performa™ MRI SureScan™ 429888Medtronic, Inc. · permanent pacemaker Electrode38 deaths3,377 reports
- CapSureFix Novus MRI™ SureScan™ 407645Medtronic, Inc. · permanent pacemaker Electrode38 deaths3,370 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page