Capsurefix® Novus 5076-52Recalls & reported problems

Medtronic, Inc. · LEAD 5076-52 CAPSUREFIX NOVUS US EN · Class 3 · Implant

Quick summary

This Medtronic Capsurefix Novus heart lead appears in 9,819 adverse event reports, including 111 deaths and 5,053 injuries. The reports mostly describe the lead missing heartbeats or sensing false signals, along with rising electrical resistance and noise, and some mention infections around the implant pocket. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
9,860
Deaths reported
111
Injuries reported
5,065
Recalls naming it
0

Summary

The FDA's MAUDE database contains 9,860 adverse event reports that list this exact device (DI 00681490124812), received between Feb 25, 2013 and Sep 30, 2026 — classified as 111 deaths, 5,065 injuries, 4,683 malfunctions.

The most frequently reported specific device problem is “Under-Sensing” (2,791 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 136 reportsDec 2023: 89 reportsJan 2024: 128 reportsFeb 2024: 92 reportsMar 2024: 98 reportsApr 2024: 105 reportsMay 2024: 72 reportsJun 2024: 69 reportsJul 2024: 101 reportsAug 2024: 92 reportsSep 2024: 93 reportsOct 2024: 106 reportsNov 2024: 86 reportsDec 2024: 54 reportsJan 2025: 116 reportsFeb 2025: 82 reportsMar 2025: 97 reportsApr 2025: 56 reportsMay 2025: 99 reportsJun 2025: 101 reportsJul 2025: 122 reportsAug 2025: 85 reportsSep 2025: 70 reportsOct 2025: 56 reportsNov 2025: 84 reportsDec 2025: 65 reportsJan 2026: 93 reportsFeb 2026: 62 reportsMar 2026: 80 reportsApr 2026: 101 reportsMay 2026: 66 reportsJun 2026: 54 reportsJul 2026: 29 reportsAug 2026: 72 reportsSep 2026: 60 reportsOct 2026: 0 reports202420252026136
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Under-Sensing2,791
  • Over-Sensing1,705
  • Adverse Event Without Identified Device or Use Problem1,657
  • High Capture Threshold1,606
  • High impedance1,323
  • Signal Artifact/Noise883
  • Fracture824
  • Failure to Capture688

Patient problems

  • No Clinical Signs, Symptoms or Conditions4,528
  • No Known Impact Or Consequence To Patient2,322
  • Unspecified Infection1,107
  • No Consequences Or Impact To Patient356
  • Dizziness162
  • Cardiac Perforation151
  • Chest Pain149
  • Dyspnea149

Recent adverse event reports

The 25 most recent of 9,860 reports, in the reporter's own words as published by the FDA.

  • InjurySep 30, 2026Failure to Capture; Fracture; High impedance

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50951782 ↗
  • MalfunctionSep 30, 2026Over-Sensing

    It was reported that the patient attended the emergency room as they experienced dizziness and near-syncope. Upon device assessment it was noted that the Right Ventricular (RV) lead was over sensing non-physiologic intervals. The RV lead remains in use. No further patient complications have been reported as a result of this event.

    Patient problems: Dizziness; Presyncope

    MAUDE report 50943147 ↗
  • InjurySep 29, 2026High Capture Threshold

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50928923 ↗
  • MalfunctionSep 28, 2026Pacing Problem; Under-Sensing

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50926263 ↗
  • MalfunctionSep 28, 2026Pacing Problem; Under-Sensing

    It was reported that the Right Atrial (RA) lead exhibited undersensing during stored Atrial Tachycardia/Atrial Fibrillation (AT/AF) episodes resulting in false termination of the AT/AF events and intermittent inappropriate pacing. The RA lead remains in use. No patient complications have been reported as a result of this event.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50918882 ↗
  • InjurySep 28, 2026Failure to Capture; Fracture; High impedance

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50918150 ↗
  • MalfunctionSep 28, 2026Under-Sensing; High Capture Threshold

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50918090 ↗
  • InjurySep 28, 2026Device Dislodged or Dislocated

    It was reported that one day post implant, an x-ray confirmed dislodgement of the Right Atrial (RA) lead. The lead was explanted and replaced. No patient complications have been reported as a result of this event.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50914841 ↗
  • InjurySep 25, 2026Signal Artifact/Noise; High impedance; Over-Sensing; Pacing Problem

    It was reported that the Right Atrial (RA) lead had exhibited Out of Range (OOR) high pacing impedance.  The lead was then reprogrammed.  Then it was noted that the waveform suspected to be noise and Far Field R-Wave (FFRW) oversensing were detected in atrial -side events and the atrial high rate pacing therapy was being delivered  in response to those waveforms. The lead was then reprogrammed off.  The lead remains in use. No patient complications have been reported as a result of this event.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50899160 ↗
  • MalfunctionSep 25, 2026Signal Artifact/Noise; Over-Sensing

    It was reported that the patient experienced dizziness and near syncope. The Right Atrial (RA) lead exhibited oversensing resulting in misclassification of episode type, Far Field R-Wave (FFRW) oversensing triggering false Atrial Tachycardia/Atrial Fibrillation ( AT/AF) detections and noise. The lead remains in use. No further patient complications have been reported as a result of this event.

    Patient problems: Dizziness; Presyncope

    MAUDE report 50897543 ↗
  • InjurySep 24, 2026Adverse Event Without Identified Device or Use Problem

    Patient problems: Discomfort; Erythema; Medical device site infection; Pain; Purulent Discharge; Swelling/ Edema

    MAUDE report 50888772 ↗
  • MalfunctionSep 24, 2026High impedance; Over-Sensing

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50884658 ↗
  • InjurySep 24, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that approximately one month post replacement procedure, the patient developed a pocket infection. It was noted that the patient developed purulent discharge/pus. The Cardiac Resynchronization Therapy Defibrillator (CRT-D) system was explanted and replaced with a Leadless Implantable Pulse Generator (IPG). No further patient complications have been reported as a result of this event.

    Patient problems: Unspecified Infection

    MAUDE report 50877022 ↗
  • MalfunctionSep 23, 2026Pacing Problem; Under-Sensing

    It was reported that the Right Atrial (RA) lead exhibited undersensing during Atrial Tachycardia/Atrial Fibrillation (AT/AF) stored episodes resulting in termination of AT/AF detected event(s) in progress. Low P waves was noted as well. The RA lead remains in use. No patient complications have been reported as a result of this event

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50866172 ↗
  • MalfunctionSep 23, 2026Pacing Problem; Under-Sensing

    It was reported that the Right Atrial (RA) lead exhibited under sensing during Atrial Tachycardia (AT)/Atrial Fibrillation (AF), resulting in unnecessary pacing at times and pre-termination of AT/AF Event in progress. The RA lead remains in use. No patient complications have been reported as a result of this event.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50865501 ↗
  • InjurySep 18, 2026Adverse Event Without Identified Device or Use Problem

    Patient problems: Fever; Itching Sensation; Medical Device Site Inflammation; Medical device site infection; Pain; Purulent Discharge

    MAUDE report 50829899 ↗
  • InjurySep 18, 2026Adverse Event Without Identified Device or Use Problem

    Patient problems: Purulent Discharge; Unspecified Infection

    MAUDE report 50828508 ↗
  • InjurySep 18, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the Implantable Cardioverter Defibrillator (ICD) system and absorbable antibacterial envelope were explanted and replaced due pocket infection and wound dehiscence. No further patient complications have been reported as a result of this event.

    Patient problems: Medical device site infection; Wound Dehiscence

    MAUDE report 50827114 ↗
  • MalfunctionSep 18, 2026Pacing Problem; Under-Sensing

    It was reported that the patient presented with chest pain, and upon review it was found that the Right Ventricular (RV) lead triggered a Lead Integrity Alert (LIA) due to increase in Sensing Integrity Counter (SIC) and two or more High Rate-Non Sustained episodes. An RV lead fracture was suspected. The lead exhibited high undefined Superior Vena Cava (SVC) coil impedance, varying pacing impedance, oversensing resulting in inhibition of pacing, noise, and high capture thresholds. All high voltage therapies were programmed off. It was also reported that the Right Atrial (RA) lead exhibited undersensing during Atrial Tachycardia/Atrial Fibrillation (AT/AF) stored episodes resulting in termination of AT/AF detected event(s) in progress, with inappropriate atrial pacing note at times. The leads remain in use. No further patient complications have been reported as a result of this event.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50819570 ↗
  • InjurySep 18, 2026Under-Sensing

    It was reported that the Right Ventricular (RV) lead exhibited under-sensing. A low amplitude tachycardia waveform was noted. The lead was reprogrammed and remains in use. No patient complications have been reported as a result of this event.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50816210 ↗
  • MalfunctionSep 18, 2026Under-Sensing

    It was reported that the Right Ventricular (RV) lead exhibited undersensing. The lead remains in use. No patient complications have been reported as a result of this event.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50814685 ↗
  • InjurySep 17, 2026Capturing Problem

    It was reported that the Right Ventricular (RV) lead exhibited increase in thresholds. Initially, the lead was programmed off, later a Leadless implantable pulse generator (IPG) was added. No patient complications have been reported as a result of this event.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50802332 ↗
  • MalfunctionSep 17, 2026Over-Sensing; Under-Sensing; Decreased Sensitivity

    It was reported that the Right Atrial (RA) lead had exhibited stored episodes for intermittent undersensing during Atrial Tachycardia/Atrial Fibrillation (AT/AF) events and Far Field R-Wave (FFRW) oversensing at times.  It was noted that the RA Lead had a low amplitude.  The lead remains in use.  No patient complications have been reported as a result of this event.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50797633 ↗
  • InjurySep 16, 2026Fracture

    It was reported that the Right Ventricular (RV) lead exhibited a fracture. The lead was explanted and replaced. No patient complications have been reported as a result of this event.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50790697 ↗
  • MalfunctionSep 16, 2026Pacing Problem; Under-Sensing

    It was reported that the Right Atrial (RA) lead exhibited undersensing during Atrial Tachycardia/Atrial Fibrillation stored episodes resulting in termination of detected events and unnecessary pacing at times. The lead remains in use. No patient complications have been reported as a result of this event

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50787946 ↗

Other Permanent defibrillator electrodes devices

All Permanent defibrillator electrodes devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.