VersaCross™ Steerable Access Solution VSTK0115Recalls & reported problems

Boston Scientific Corporation · Steerable Access Solution · Class 2

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00685447019657), received between Nov 24, 2025 and Sep 18, 2026 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 2 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Delivered as Unsterile Product1
  • Fluid/Blood Leak1
  • Material Integrity Problem1
  • Unsealed Device Packaging1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 18, 2026Fluid/Blood Leak

    It was reported that during a Pulsed Field Ablation (PFA) procedure for the treatment of atypical atrial flutter, a VersaCross Steerable Access Solution was selected for use. The dilator was inserted into the sheath without resistance, followed by advancement of the FARAPOINT catheter and ORION mapping catheter across the valve. No resistance was encountered during insertion of the ORION mapping catheter. During the procedure, the physician observed significant leakage from the sheath valve, described as a fast drip of saline during flushing. The syringe was securely attached to the handle luer, and no damage to the device or luer was noted. There was no air leakage or air observed in the patient, and no error messages were displayed. No RF generator was used. The procedure was successfully completed without troubleshooting. The patient remained stable, and no patient complications were reported as a result of the event.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50819349 ↗
  • MalfunctionApr 13, 2026Delivered as Unsterile Product; Unsealed Device Packaging

    IT WAS REPORTED THAT PRIOR TO AN ATRIAL FIBRILLATION PROCEDURE, PULSE FIELD ABLATION PROCEDURE A VERSACROSS STEERABLE ACCESS SOLUTION WAS SELECTED FOR USE. UPON OPENING THE VERSACROSS PACKAGE, IT WAS NOTED TO HAVE A PARTIALLY OPEN SEAL. THE DEVICE WAS NOT STERILE AND DISCARDED. THE PROCEDURE WAS CANCELLED. NO PATIENT WAS NOTED TO BE PRESENT AT THE TIME OF THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24865662 ↗
  • MalfunctionApr 1, 2026Material Integrity Problem

    IF WAS REPORTED THAT DURING A PULSED FIELD ABLATION (PFA) PROCEDURE WITH VARIPULSE TO TREAT AN ATRIAL FIBRILLATION, THE COATING OF THE VERSACROSS WIRE WAS COMING OFF AND EXPOSED AT PROXIMAL END OF THE WIRE. A NEW DEVICE WAS USED TO COMPLETE THE PROCEDURE. NO PATIENT COMPLICATIONS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24760571 ↗
  • MalfunctionNov 24, 2025Break; Break

    IT WAS REPORTED THAT DURING THE PULMONARY VEIN ISOLATION TO TREAT ATRIAL FIBRILLATION VERSACROSS STEERABLE ACCESS SOLUTION WERE SELECTED FOR USE. IT HAS BEEN MENTIONED THAT BEFORE THE INSERTION STOPCOCK BROKE OFF. THE PROCEDURE WAS COMPLETED USING DIFFERENT DEVICE (SAME MODEL). THE PRODUCT IS NOT EXPECTED TO RETURN AS DISPOSED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23638294 ↗

Other Percutaneous atrial catheter kit devices

All Percutaneous atrial catheter kit devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.