CO-SET+ 93522Recalls & reported problems
Edwards Lifesciences LLC · CO-SET INJECTATE PROBE CABLE · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00690103003260), received between Sep 2, 2022 and Jun 13, 2025 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Incorrect, Inadequate or Imprecise Result or Readings2
- Incorrect Measurement1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 13, 2025Incorrect Measurement; Incorrect Measurement
AS REPORTED, DURING USE IN PATIENT, THIS CO-SET INJECTATE PROBE CABLE WAS UNABLE TO OBTAIN BASAL TEMPERATURE. THEN, 0 C DEGREE WAS USED TO ESTIMATE THE CARDIAC OUTPUT (CO) AND THE CALCULATION WAS TOO HIGH. VALUES WERE UNABLE TO BE USED. A NOTE SAYING: "THE INJECTABLE THERMISTOR IS NOT CONNECTED. 0C WILL BE USED AS THE INJECTABLE TEMPERATURE" WAS DISPLAYED. THE CO WAS ALSO CALCULATED WITH FICK FORMULA BUT IT WAS MORE INCORRECT WAY OF ESTIMATE CO SINCE THE PATIENT HAS BEEN THERE BEFORE AND IT WAS CALCULATED WITH THERMODILUTION. THERE WAS NO ALLEGATION OF PATIENT INJURY. PATIENT DEMOGRAPHICS WERE REQUESTED AND UNABLE TO BE PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22201144 ↗MalfunctionSep 2, 2022Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
IT WAS REPORTED THAT THE 93522 CO SET CABLE WOULD NOT READ A TEMPERATURE OF THE INJECTATE AT ALL AND IT WOULD READ THE TEMPERATURE LOW. IF THE TEMPERATURE WAS READ LOW IT WOULD GIVE FALSELY HIGH VALUES FOR CARDIAC INDEX OUTPUT AND SKEW THE REST OF THE HEMODYNAMIC PROFILE. WHEN COMPARING THESE THERMODILUTION VALUES TO THE FICK CARDIAC INDEX AND OUTPUT CALCULATED FROM AN SVO2 FROM THE SAME PATIENT IT WAS CLEAR THAT SOMETHING WAS AMISS. THEY KNEW WHEN THEY WERE RECEIVING OUTPUTS OF 14 TO 15 THERE WAS NO WAY IT WAS ACCURATE. PATIENTS WERE NOT TREATED BASED ON THESE NUMBERS. THEY WERE ABLE TO TROUBLESHOOT BY EXCHANGING THE SUSPECT CABLE. PATIENT DEMOGRAPHICS WERE UNAVAILABLE. THIS WAS DURING USE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15352449 ↗MalfunctionSep 2, 2022Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
IT WAS REPORTED THAT THE 93522 CO SET CABLE WOULD NOT READ A TEMPERATURE OF THE INJECTATE AT ALL AND IT WOULD READ THE TEMPERATURE LOW. IF THE TEMPERATURE WAS READ LOW IT WOULD GIVE FALSELY HIGH VALUES FOR CARDIAC INDEX OUTPUT AND SKEW THE REST OF THE HEMODYNAMIC PROFILE. WHEN COMPARING THESE THERMODILUTION VALUES TO THE FICK CARDIAC INDEX AND OUTPUT CALCULATED FROM AN SVO2 FROM THE SAME PATIENT IT WAS CLEAR THAT SOMETHING WAS AMISS. THEY KNEW WHEN THEY WERE RECEIVING OUTPUTS OF 14 TO 15 THERE WAS NO WAY IT WAS ACCURATE. PATIENTS WERE NOT TREATED BASED ON THESE NUMBERS. THEY WERE ABLE TO TROUBLESHOOT BY EXCHANGING THE SUSPECT CABLE. PATIENT DEMOGRAPHICS WERE UNAVAILABLE. THIS WAS DURING USE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15352416 ↗
FDA clearance and classification
Cleared through 510(k) K811399 on Jun 9, 1981 (decision: Substantially Equivalent). Submitted by American Edwards Laboratories as “Edslab Closed Injectate Delivery System”. The FDA review took 21 days. FDA record ↗
The FDA regulates product code KRB (probe, thermodilution) under 21 CFR 870.1915 as a Class II device. 21 CFR 870.1915 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the CO-SET+ 93522
Has the CO-SET+ 93522 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00690103003260), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the CO-SET+ 93522?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Sep 2, 2022 and Jun 13, 2025. In those reports, the most common specific device problems are “Incorrect, Inadequate or Imprecise Result or Readings” (2) and “Incorrect Measurement” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the CO-SET+ 93522?
None of the reports are classified as deaths, 0 as injuries and 3 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the CO-SET+ 93522 FDA approved?
It was cleared through 510(k) K811399 on Jun 9, 1981. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the CO-SET+ 93522, and is it still sold?
The FDA's device database lists Edwards Lifesciences LLC as the company responsible for it (brand CO-SET+, model 93522). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other PROBE, THERMODILUTION devices
- PiCCO Catheter PV2015L20-APulsion Medical Systems SE · Probe, Thermodilution24 reports
- PiCCO Catheter PV2014L16-APulsion Medical Systems SE · Probe, Thermodilution16 reports
- CO-SET+ 93505Edwards Lifesciences LLC · PROBE, THERMODILUTION9 reports
- PiCCO Catheter PV2014L22-APulsion Medical Systems SE · Probe, Thermodilution8 reports
- VolumeView VLV8R520Edwards Lifesciences LLC · PROBE, THERMODILUTION4 reports
- PiCCO Catheter PV2014L16NPulsion Medical Systems SE · Probe, Thermodilution3 reports
- CO-SET+ 93600Edwards Lifesciences LLC · PROBE, THERMODILUTION1 report
- PiCCO Catheter PV2015L20NPulsion Medical Systems SE · Probe, Thermodilution1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.