Pulsion Medical Systems SE · 4F Thermodilution catheter, 220mm · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 04250094500979), received between Apr 21, 2021 and Mar 5, 2025 — classified as 2 injuries, 6 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 2 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break2
  • Material Fragmentation2
  • Stretched2
  • Unraveled Material2
  • Material Deformation1
  • Material Integrity Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions6
  • Foreign Body In Patient2

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 5, 2025Material Deformation; Material Deformation

    IT WAS REPORTED THAT WHEN INSERTING THE CATHETER, THE NEEDLE TIP (PINK) GOT CAUGHT ON THE GUIDE WIRE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21525692 ↗
  • MalfunctionNov 7, 2024Stretched; Unraveled Material; Stretched; Unraveled Material

    MANUFACTURER REFERENCE # (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20628507 ↗
  • MalfunctionNov 7, 2024Stretched; Unraveled Material; Stretched; Unraveled Material

    MANUFACTURER REFERENCE # (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20628497 ↗
  • MalfunctionAug 29, 2023Material Integrity Problem; Material Integrity Problem

    ACCORDING TO THE USER REPORT FROM THE FEDERLA INSTITUTE FOR DRUGS AN MEDICAL DEVICES GERMANY : WHEN INSTALLING THE ABOVE-MENTIONED CATHETER (PV2014L22-A, PICCO CATHETER 4F, 22CM, LOT 708891), AFTER INSERTING THE GUIDE WIRE, THE DILATOR COULD NOT BE THREADED ONTO THE NITINOL SELDINGER WIRE DUE TO RESISTANCE IN THE PROXIMAL LUMEN. THE STENOSIS APPEARS TO BE AT THE TRANSITION FROM THE LUER CONNECTOR TO THE DILATOR SHAFT. BY USING A NEW SET WITH A DIFFERENT DILATOR, THE CATHETER COULD FINALLY BE PLACED. THE PROCEDURE WAS PROLONGED AS A RESULT, AND ACCORDING TO THE CURRENT FINDINGS, NO HARM TO THE PATIENT CAN BE ASSUMED. THE CATHETER ITSELF WAS PRESERVED FOR THE EXAMINATION TOGETHER WITH THE DILATOR AND NITINOL-SELDINGER WIRE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17642039 ↗
  • InjuryNov 26, 2022Material Fragmentation; Material Fragmentation

    IT HAS BEEN REPORTED THAT PART OF THE CATHETER TIP FROM THE GUIDE WIRE REMAINED IN THE PATIENT'S VESSEL AND HAD TO BE REMOVED. MANUFACTURER REFERENCE: #(B)(4).

    Patient problems: Foreign Body In Patient

    MAUDE report 15866918 ↗
  • InjuryNov 24, 2022Material Fragmentation; Material Fragmentation

    IT HAS BEEN REPORTED THAT PART OF THE CATHETER TIP FROM THE GUIDE WIRE REMAINED IN THE PATIENT'S VESSEL AND HAD TO BE REMOVED. MANUFACTURER REFERENCE: (B)(4).

    Patient problems: Foreign Body In Patient

    MAUDE report 15860404 ↗
  • MalfunctionApr 21, 2021Break; Break

    A CATHETER HAS BEEN PLACED RIGHT FEMORAL ON (B)(6) 2021. IMMEDIATELY NO MEASUREMENTS POSSIBLE. THERE WAS NO TEMPERATURE READING. ON (B)(6) 2021 FINALLY SUCCEEDED IN ONE MEASUREMENT. NO LEAKAGE DETECTED FOR THIS CATHETER. ON (B)(6) 2021 NEW PICCO CATHETER HAS BEEN PLACED BRACHIAL UNDER ECHO ON THE LEFT. ONE MEASUREMENT SUCCESSFUL, CATHETER NOT DETECTED AFTERWARDS. ON (B)(6) 2021 IT HAS BEEN DETECTED VISUALLY THAT THERE IS BLOOD IN THE WHITE CONNECTION CABLE. THE CASE IS REPORTED AS LEAKING PARTS IN CONTACT WITH ARTERIAL BLOOD PRESSURE HAVE BEEN REPORTED. NO HARM OR CLINICAL CONSEQUENCES OCCURRED TO THE PATIENT. MANUFACTURER REFERENCE: #(B)(4). ON (B)(6) 2021, NEW CATHETER PLACED LEFT BRACHIAL AGAIN. ON THE NEXT DAY, AGAIN NO MEASUREMENT POSSIBLE. CATHETER NOT DETECTED. ON (B)(6) 2021 NO MEASUREMENTS POSSIBLE AT FIRST, BUT A FEW HOURS LATER. A LEAKAGE IN THE WHITE CONNECTION CABLE HAS BEEN DETECTED FOR THIS CATHETER AS WELL. THE CASE WAS EVALUATED AS REPORTABLE AS LEAKING PARTS IN CONTACT WITH ARTERIAL BLOOD PRESSURE HAVE BEEN REPORTED (REFER TO REPORT WITH MANUFACTURER REFERENCE #(B)(4)).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11698874 ↗
  • MalfunctionApr 21, 2021Break; Break

    MANUFACTURER REFERENCE: # (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11698872 ↗

Other Probe, Thermodilution devices

All Probe, Thermodilution devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page