GORE VIABIL Biliary Endoprosthesis VN1006200Recalls & reported problems
W. L. Gore & Associates, Inc. · GORE VIABIL BILIARY ENDO 10mmX6cm 8.5Fr · Class 2 · Implant
All models of GORE VIABIL Biliary Endoprosthesis (11)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00733132615759), received between May 31, 2019 and May 31, 2019 — classified as 1 death.
The most frequently reported specific device problem is “Material Deformation” (1 report).
1 other recall cover devices cleared under the same FDA submission (K081184); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Material Deformation1
- Separation Failure1
Patient problems
- Blood Loss1
- Death1
- Hemorrhage/Blood Loss/Bleeding1
- Shock1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
DeathMay 31, 2019Separation Failure; Material Deformation; Separation Failure; Material Deformation
IT WAS REPORTED TO GORE BY CONMED, (CEN-2064) THAT DURING AN ERCP ON A MALE PATIENT ON (B)(6) 2019, THE PHYSICIAN PLACED A 10X6 GORE® VIABIL® BILIARY ENDOPROSTHESIS FOR DISTAL BILIARY STRICTURE. IT WAS REPORTED THAT UPON FULL DEPLOYMENT OF THE VIABIL, THE DELIVERY CATHETER COULD NOT BE WITHDRAWN BY THE PHYSICIAN. ACCORDING TO THE REPORT, AFTER WAITING A PERIOD OF TIME TO ALLOW FOR RELAXING, THE CATHETER COULD STILL NOT BE REMOVED, EVEN WITH A REPORTED STRONG REMOVAL FORCE. IT WAS REPORTED THE PHYSICIAN SUBSEQUENTLY CUT THE HUB END OF THE CATHETER OFF AT THE SCOPE PORT AND WENT BACK ALONG SIDE THE CATHETER AND PROCEEDED TO DILATE THE VIABIL SUCCESSFULLY WITH A 4MM DILATION BALLOON. REPORTEDLY, THE STENT WAS DRAINING, HOWEVER, THE CATHETER STILL COULD NOT BE REMOVED. ACCORDING TO THE REPORT, THE PHYSICIAN ATTEMPTED REMOVAL WITH A RAT TOOTH, PULLING WITH STRONG FORCE, HOWEVER HE WAS STILL NOT ABLE TO REMOVE THE STENT. REPORTEDLY, THE STENT WAS OBSERVED TO DEFORM A BIT AND A BEND WAS NOTED IN THE IMAGING, SHAPING THE STENT LIKE A U ABOUT THE MIDPOINT. IT WAS REPORTED THE PHYSICIAN ATTEMPTED APC AT 50 WATTS AND ENDOSCOPIC SCISSORS. REPORTEDLY, BOTH WERE UNSUCCESSFUL. IT WAS REPORTED THE
Patient problems: Blood Loss; Death; Hemorrhage/Blood Loss/Bleeding; Shock
MAUDE report 8660292 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K081184. One submission often covers many models, so check the product and lot details in each record.
- Z-1593-2021 · Apr 5, 2021 · TerminatedGORE VIBIL Biliary Endoprosthesis: stents, drains and dilators for the biliary ducts. Catalogue numbers: VH1008040, VH1010040, VN1010040, VN0808200 - Product Usage: intended for pa
Other Catheter, Biliary, Diagnostic devices
- Hurricane™ RX M00545900Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls1 death705 reports
- MUSTANG™ H74939171060470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC384 reports
- CRE™ PRO M00558710Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC1 recall284 reports
- Hurricane™ RX M00545920Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls211 reports
- MUSTANG™ H74939171070470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC265 reports
- MUSTANG™ H74939171050470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC212 reports
- Hurricane™ RX M00545940Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls109 reports
- MUSTANG™ H74939171100470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC203 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page