Viva™ XT CRT-D DTBA1D4 (UDI 00763000059668)Recalls & reported problems
Medtronic, Inc. · CRTD DTBA1D4 VIVA XT US IS1/DF4 · Class 3 · Implant
All models of Viva XT CRT-D (10)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 15
- Deaths reported
- 2
- Injuries reported
- 11
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 15 adverse event reports that list this exact device (DI 00763000059668), received between Aug 24, 2018 and Feb 20, 2024 — classified as 2 deaths, 11 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Inappropriate/Inadequate Shock/Stimulation” (4 reports).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Recalls naming this device
- May 10, 2023Class IOpen, Classified
There is a rare potential for reduced- or no-energy output during high voltage (HV) therapy (typically 0-12J) in implantable cardioverter defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds) manufactured with a specific (glassed) feedthrough, including currently available ICDs and CRT-Ds.
Z-1731-2023 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem6
- Inappropriate/Inadequate Shock/Stimulation4
- Device Sensing Problem3
- Premature Discharge of Battery2
- Appropriate Device Problem Term/Code Not Available1
- Electrical /Electronic Property Problem1
- Insufficient Device Problem Information1
Patient problems
- Unspecified Infection5
- Shock from Patient Lead(s)3
- Death2
- Discharge1
- Dyspnea1
- Erosion1
- Hematoma1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 15 most recent of 15 reports, in the reporter's own words as published by the FDA.
InjuryFeb 20, 2024Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED THAT THE PATIENT HAD AN UNRESPONSIVE EPISODE AND THE PHYSICIAN FEELS THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) IS NOT WORKING PROPERLY. ADDITIONALLY, IT WAS NOTED THAT THE RIGHT ATRIAL (RA) LEAD POSITION CHECK FAILED. THE CRT-D AND RA LEAD REMAIN IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Syncope/Fainting
MAUDE report 18741175 ↗InjuryAug 23, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT PRESENTED TO THE HOSPITAL WITH SEPSIS. THE LEFT SIDED CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SYSTEM WAS EXPLANTED SECONDARY TO THE INFECTION. THE PRIMARY SOURCE WAS NOTED TO NOT BE DEVICE OR POCKET RELATED, HOWEVER, THE SOURCE IS UNKNOWN. A NEW CRT-D SYSTEM WAS IMPLANTED ON THE RIGHT SIDE 2 WEEKS LATER. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Sepsis; Unspecified Infection
MAUDE report 17604631 ↗InjuryOct 29, 2022Premature Discharge of Battery; Premature Discharge of Battery
IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) WAS EXPLANTED AND REPLACED DUE TO PREMATURE BATTERY DEPLETION. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15696608 ↗MalfunctionNov 19, 2021Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
FOLLOW UP REVEALED THE ALERT WAS RELATED TO A MISSED REMOTE TRANSMISSION AND AN EPISODE OF ATRIAL FIBRILLATION (AF). THE ALERTS WERE RESET BUT NO OTHER CHANGES WERE MADE TO THE DEVICE SETTINGS.
Patient problems: Dyspnea
MAUDE report 12845410 ↗InjuryNov 2, 2020Premature Discharge of Battery; Premature Discharge of Battery
IT WAS REPORTED BY THE PATIENT THAT THEIR PREVIOUS DEVICE BATTERY DRAINED FASTER THAN EXPECTED. THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) WAS EXPLANTED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10771034 ↗DeathAug 24, 2020Inappropriate/Inadequate Shock/Stimulation; Inappropriate/Inadequate Shock/Stimulation
IT WAS REPORTED THAT THE PATIENT RECEIVED MULTIPLE INAPPROPRIATE SHOCKS AND REQUESTED DEFIBRILLATION THERAPY FROM THEIR CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) AND RIGHT VENTRICULAR (RV) LEAD BE TURNED OFF. THE DEVICE WAS INACTIVATED AT THE PATIENT'S REQUEST AND IT WAS NOTED WITHOUT THERAPY, THE PATIENT LATER PASSED AWAY. THE PATIENT WAS A PARTICIPANT IN A CLINICAL STUDY.
Patient problems: Death
MAUDE report 10442877 ↗InjuryMar 11, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SYSTEM WAS REMOVED DUE TO INFECTION AND DEVICE EROSION THROUGH THE SKIN. PUS DRAINAGE WAS NOTED. CULTURES WERE OBTAINED AND ANTIBIOTICS WERE ADMINISTERED. A NEW CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P) SYSTEM WAS IMPLANTED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT
Patient problems: Discharge; Erosion; Unspecified Infection
MAUDE report 9818264 ↗InjuryMar 4, 2020Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem; Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem
IT WAS REPORTED THAT THE PATIENT RECEIVED AN INAPPROPRIATE SHOCK FOR ATRIAL FIBRILLATION (AF) WITH RAPID VENTRICULAR RESPONSE THAT WAS DETECTED AS VENTRICULAR FIBRILLATION (VF). THE DEVICE REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Shock from Patient Lead(s)
MAUDE report 9786924 ↗MalfunctionJun 24, 2019Electrical /Electronic Property Problem; Electrical /Electronic Property Problem
IT WAS REPORTED THAT DURING PRE-IMPLANT DEVICE CHECK, THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) INTERROGATION DISPLAYED A GRAY BAR INDICATING THE ESTIMATED REMAINING BATTERY VOLTAGE WAS NOT AVAILABLE. THE DEVICE WAS NOT IMPLANTED. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Patient Involvement
MAUDE report 8729473 ↗InjuryJun 14, 2019Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem; Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem
IT WAS REPORTED THAT THERE WAS A POSSIBLE INAPPROPRIATE SHOCK FOR ATRIAL FIBRILLATION (AF) WITH RAPID VENTRICULAR RESPONSE THAT THE DEVICE DETECTED AS FAST VENTRICULAR TACHYCARDIA (VT). THERE WAS A HIGH THRESHOLD ALERT ON THE RIGHT ATRIAL (RA) LEAD. THE DEVICE AND LEAD REMAIN IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Shock from Patient Lead(s)
MAUDE report 8701110 ↗InjuryMar 19, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT HAD AN INFECTION. THE DEVICE WAS EXPLANTED AND NOT REPLACED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Unspecified Infection
MAUDE report 8434616 ↗InjuryMar 1, 2019Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem; Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem
IT WAS REPORTED THAT THE PATIENT'S CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) WAS CHECKED AS THEY WERE FOUND UNRESPONSIVE. REVIEW OF THE DEVICE DATA INDICATED A HIGH RIGHT ATRIAL (RA) LEAD THRESHOLD. IT WAS NOTED THE PATIENT HAD ALSO EXPERIENCED A SHOCK FOR FAST VENTRICULAR TACHYCARDIA (VT) SEVERAL MONTHS PRIOR FOR WHAT APPEARED TO BE ATRIAL FIBRILLATION (AF) WITH RAPID VENTRICULAR RESPONSE. THERE WERE NO CLINICAL ACTIONS NOTED AT THIS TIME. THE RA LEAD AND CRT-D REMAIN IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Shock from Patient Lead(s)
MAUDE report 8384006 ↗InjurySep 7, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SYSTEM WAS REMOVED DUE TO A (B)(6) AND VEGETATION ON THE RIGHT VENTRICULAR (RV), RIGHT ATRIAL (RA) AND LEFT VENTRICULAR (LV) LEADS. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Unspecified Infection
MAUDE report 7857561 ↗InjuryAug 30, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT DEVELOPED A POCKET HEMATOMA AFTER THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) IMPLANT AND THE INCISION DEHISCED. THE CRT-D SYSTEM WAS SCHEDULED FOR REVISION AND THE RIGHT VENTRICULAR (RV) LEAD AND RIGHT ATRIAL (RA) LEAD LEADS WERE REMOVED. THE LEFT VENTRICULAR (LV) LEAD WAS PARTIALLY EXPLANTED AND THE SYSTEM WAS LATER REPLACED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Hematoma; Unspecified Infection; Wound Dehiscence
MAUDE report 7834738 ↗DeathAug 24, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT DURING THE IMPLANT OF THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SYSTEM, DEFIBRILLATION TESTING WAS UNSUCCESSFUL. THE PATIENT THEN REQUIRED EXTERNAL DEFIBRILLATION. THE RIGHT VENTRICULAR LEAD WAS REPOSITIONED AND DEFIBRILLATION TESTING WAS AGAIN UNSUCCESSFUL. THE PATIENT WAS TRANSFERRED TO THE INTENSIVE CARE UNIT. THE PATIENT CONTINUED TO HAVE VENTRICULAR FIBRILLATION WHICH WAS TREATED WITH MEDICATIONS AND EXTERNAL DEFIBRILLATION WITH PLANS TO RETEST AT A LATER DATE. HOWEVER, THE PATIENT PASSED AWAY TWO DAYS LATER. THE CAUSE OF DEATH WAS REQUESTED AND NOT AVAILABLE.
Patient problems: Death; Ventricular Fibrillation
MAUDE report 7814889 ↗
Other Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D) devices
- Gallant™ CDHFA500QSt. Jude Medical, Inc. · Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D)2 recalls58 deaths8,401 reports
- Quartet™ 1458Q-86St. Jude Medical, Inc. · Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D)207 deaths6,631 reports
- QUADRA ASSURA MP™ CD3369-40QSt. Jude Medical, Inc. · Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D)103 deaths6,084 reports
- VIGILANT™ X4 CRT-D G247Boston Scientific Corporation · Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D)17 deaths2,066 reports
- Quadra Assura™ CD3365-40QSt. Jude Medical, Inc. · Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D)53 deaths2,056 reports
- Cobalt™ XT HF Quad CRT-D MRI SureScan™ DTPA2QQMedtronic, Inc. · Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D)4 recalls40 deaths1,639 reports
- Unify Assura™ CD3357-40QSt. Jude Medical, Inc. · Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D)54 deaths1,784 reports
- Unify Assura™ CD3357-40CSt. Jude Medical, Inc. · Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D)56 deaths1,588 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page