NanoCross™ Elite AB14W060100150 (UDI 00763000110468)Recalls & reported problems
Ev3, Inc · PTA AB14W060100150 NANOCROSS 014 V05 · Class 2
All models of NanoCross Elite (63)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00763000110468), received between May 10, 2022 and Aug 26, 2022 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).
1 other recall cover devices cleared under the same FDA submission (K141118); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Detachment of Device or Device Component1
- Difficult to Remove1
- Leak/Splash1
Patient problems
- Insufficient Information1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 26, 2022Leak/Splash; Leak/Splash
A PHYSICIAN WAS USING A NANOCROSS BALLOON TO TREAT THE LEFT SFA OF A PATIENT. NO TORTUOSITY REPORTED AND MODERATED CALCIFICATION. 50% LESION STENOSIS. A 6F SHEATH, 014 GUIDEWIRE AND NO EMBOLIC PROTECTION WERE USED. NO DAMAGE NOTED TO PACKAGING. NO ISSUES NOTED WHEN REMOVING DEVICE FROM HOOP/TRAY. THE IFU WAS FOLLOWED. THE BALLOON WAS INFLATED WITH A NON-MEDTRONIC INSUFFLATOR. IT IS REPORTED THE BALLOON STARTED LEAKING FLUID AND IT DID NOT INFLATE AS HE NEED IT DURING USE. THE PROCEDURE WAS COMPLETED WITH A NEW BALLOON. NO VESSEL DAMAGE DUE TO EVENT. NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15300182 ↗InjuryMay 10, 2022Difficult to Remove; Detachment of Device or Device Component; Difficult to Remove; Detachment of Device or Device Component
PATIENT UNDERWENT PROCEDURE FOR PRE-OPERATIVE DIAGNOSIS OF AN ABDOMINAL AORTIC ANEURYSM (AAA), LARGE 6.1CM. THE PROCEDURE PLAN WAS TO PLACE AN INFRARENAL GRAFT WITH FIXATION, POTENTIAL NEED FOR EXTENSION AND SNORKELING OF THE RENALS. THE PATIENT WAS PREPPED AND DRAPED IN THE USUAL FASHION. USING TYPICAL TECHNIQUE AND ULTRASOUND GUIDANCE, AND AVOIDING THE PREVIOUS RECENT FEMORAL CANNULATIONS FOR TAVR, THE FEMORAL ARTERIES WERE IDENTIFIED AND CANNULATED USING ULTRASOUND GUIDANCE (USG) AND MICRO PUNCTURE TECHNIQUES. AFTER PASSING WIRES, THE PHYSICIAN SIZED UP TO 11FR SHEATHS. USING MULTIPLE CATHETERS, THE PHYSICIAN WAS ABLE TO GUIDE WIRES INTO THE THORACIC AORTA AVOIDING THE TAVR VALVE. A PIGTAIL CATHETER WAS PLACED IN THE SUPRARENAL LOCATION. THE NECK WAS VISUALIZED AS WELL AS THE LOWEST RENAL ARTERY. A GRAFT WAS PLACED FROM THE RIGHT. FOLLOWING PLACEMENT OF THE GRAFT, THE GRAFT JUNCTIONS WERE BALLOONED. FOLLOWING THIS PRIOR TO ANY OTHER FURTHER ANGIOGRAPHY WAS PERFORMED A FIXATION DEVICE WAS USED IN 7 LOCATIONS ON THE GRAFT TO WALL JUNCTION NEAR THE LEFT RENAL ARTERY LEVEL. CONTRAST ANGIOGRAPHY WAS THEN PERFORMED WITH A POWER INJECTOR, WITH ENDOLEAK VISIBLE. DESPITE MULTIPLE ATTEMPT
Patient problems: Insufficient Information
MAUDE report 14345217 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K141118. One submission often covers many models, so check the product and lot details in each record.
- Z-0904-2025 · Dec 10, 2024 · Open, ClassifiedMedtronic NanoCross Elite PTA catheter, REF numbers amd sizes: 1) AB14W050020090, Size: 5MM X 20MM X 90CM; 2) AB14W050020150, Size: 5MM X 20MM X 150CM; 3) AB14W050040090,
Other Catheter, angioplasty, peripheral, transluminal devices
- Coyote™ ES H74939135152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal879 reports
- Coyote™ ES H74939135204010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal585 reports
- Coyote™ ES H74939135202010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal437 reports
- Coyote™ ES H74939135304010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal384 reports
- Coyote™ ES H74939135404010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal293 reports
- Coyote™ ES H74939134152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal279 reports
- Coyote™ H74939185202210Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal200 reports
- Coyote™ ES H74939135254010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal127 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page