NanoCross™ Elite AB14W060120090Recalls & reported problems
Ev3, Inc · PTA AB14W060120090 NANOCROSS 014 V05 · Class 2
All models of NanoCross Elite (63)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00763000110475), received between Sep 8, 2022 and Sep 8, 2022 — classified as 1 malfunction.
The most frequently reported specific device problem is “Deflation Problem” (1 report).
1 other recall cover devices cleared under the same FDA submission (K141118); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Deflation Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 8, 2022Deflation Problem; Deflation Problem
PHYSICIAN WAS ATTEMPTING TO USE A NANOCROSS ELITE PTA BALLOON ALONG WITH NON-MEDTRONIC 6FR SHEATH AND 0.014" GUIDEWIRE DURING PROCEDURE TO TREAT A LITTLE CALCIFIED, PLAQUE LESION IN THE LEFT MID SUPERFICIAL FEMORAL ARTERY (SFA) WITH 60%- 70% STENOSIS. THE VESSEL WAS MODERATELY TORTUOUS. THE VESSEL DIAMETER AND LESION LENGTH WAS 6MM AND 150MM RESPECTIVELY. NO EMBOLIC PROTECTION WAS USED. A NON-MEDTRONIC INFLATION WAS USED FOR BALLOON INFLATION. THERE WAS NO DAMAGE NOTED TO PACKAGING. THERE WAS NO ISSUE NOTED WHEN REMOVING DEVICE FROM HOOP/TRAY. IT WAS REPORTED THAT BALLOON DEFLATION DIFFICULTIES OCCURRED WITH DEVICE SLOW TO DEFLATE AT THE LESION SITE. THE DEVICE DID NOT PASS THROUGH A PREVIOUSLY DEPLOYED STENT. THERE WAS NO RESISTANCE ENCOUNTERED WHEN ADVANCING THE DEVICE. INITIAL INFLATION FLAWLESS, UPON DEFLATION IT WAS EXTREMELY SLOW. DOUBLE NEGATIVE APPLIED TO INFLATION DEVICE IN ADDITION TO MANUAL ASPIRATION WITH 20CC SYRINGE VIA SIDE PORT OF INFLATION DEVICE. BALLOON REMOVED WITHOUT DIFFICULTY. STENT WAS UTILIZED. RE-ADVANCED PTA. INFLATION DEVICE ADDED 8 ML OF HEPARIN SALINE. UPON INFLATION PTA WAS NOT WELL VISUALIZED AT 12ATM, DEFLATED AND REINFLATED AT 12 ATM WITH NO CHANGE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15377071 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K141118. One submission often covers many models, so check the product and lot details in each record.
- Z-0904-2025 · Dec 10, 2024 · Open, ClassifiedMedtronic NanoCross Elite PTA catheter, REF numbers amd sizes: 1) AB14W050020090, Size: 5MM X 20MM X 90CM; 2) AB14W050020150, Size: 5MM X 20MM X 150CM; 3) AB14W050040090,
Other Catheter, angioplasty, peripheral, transluminal devices
- Coyote™ ES H74939135152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal879 reports
- Coyote™ ES H74939135204010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal585 reports
- Coyote™ ES H74939135202010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal437 reports
- Coyote™ ES H74939135304010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal384 reports
- Coyote™ ES H74939135404010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal293 reports
- Coyote™ ES H74939134152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal279 reports
- Coyote™ H74939185202210Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal200 reports
- Coyote™ ES H74939135254010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal127 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page