EverCross™ AB35W07040135 (UDI 00763000184599)Recalls & reported problems
Ev3, Inc · PTA AB35W07040135 EVERCROSS 035 V09 · Class 2
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00763000184599), received between Sep 2, 2020 and Sep 2, 2021 — classified as 1 injury, 2 malfunctions.
The most frequently reported specific device problem is “Burst Container or Vessel” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Burst Container or Vessel3
- Detachment of Device or Device Component1
- Difficult to Remove1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 2, 2021Burst Container or Vessel; Burst Container or Vessel
PHYSICIAN WAS ATTEMPTING TO USE EVERCROSS PTA BALLOON ALONG WITH NON-MEDTRONIC 6FR SHEATH AND 0.035" J-WIRE DURING PROCEDURE TO TREAT A MODERATELY CALCIFIED LESION IN THE LEFT PROXIMAL SUPERFICIAL FEMORAL ARTERY (SFA) WITH 90% STENOSIS. THE VESSEL WAS LITTLE TORTUOUS. THE VESSEL DIAMETER AND LESION LENGTH WERE 7MM AND 30MM RESPECTIVELY. NO EMBOLIC PROTECTION WAS USED. A NON-MEDTRONIC INFLATION DEVICE WAS USED FOR BALLOON INFLATION. A 50/50 CONTRAST WAS USED AS INFLATION FLUID. THERE WAS NO DAMAGE NOTED TO PACKAGING. THERE WAS NO ISSUE NOTED WHEN REMOVING THE DEVICE FROM HOP/TRAY. THE DEVICE WAS PREPPED PER IFU WITH NO ISSUES IDENTIFIED. IT WAS REPORTED THAT DURING BALLOON INFLATION, BALLOON CIRCUMFERENTIAL/RADIAL BURST OCCURRED AT 8ATM. ALL FRAGMENTS OF THE BALLOON WERE RETRIEVED. BALLOON WAS PLACED ACROSS THE LESION AND DURING INFLATION RUPTURED. ALL PARTS OF THE BALLOON WERE REMOVED AND NO VESSEL INJURY WAS NOTED. THE DEVICE DID NOT PASS THROUGH A PREVIOUSLY DEPLOYED STENT. RESISTANCE WAS ENCOUNTERED WHEN ADVANCING THE DEVICE. NO INTERVENTION WAS NEEDED, AS ALL PARTS OF BALLOON WERE STILL OK BALLOON CATHETER. DEVICE WAS SAFELY REMOVED FROM PATIENT. TWO INFLATIONS WERE APPLIED TO
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12412627 ↗MalfunctionMar 26, 2021Burst Container or Vessel; Burst Container or Vessel
PHYSICIAN WAS ATTEMPTING TO USE EVERCROSS PTA BALLOON ALONG WITH A NON-MEDTRONIC 6FR SHEATH AND 0.014" NITREX GUIDEWIRE DURING PROCEDURE TO TREAT A MODERATELY CALCIFIED PLAQUE LESION IN THE LEFT PROXIMAL SUPERFICIAL FEMORAL ARTERY (SFA) WITH 75% STENOSIS. THE VESSEL IS NONE TORTUOUS. THE VESSEL DIAMETER AND LESION LENGTH ARE 7MM AND 30MM RESPECTIVELY. A NON-MEDTRONIC DEVICE WAS USED FOR INFLATION. A 60 SALINE/40 CONTRAST WAS USED FOR INFLATION FLUID. THERE WAS NO DAMAGE NOTED TO PACKAGING. THERE WAS NO ISSUE NOTED WHEN REMOVING DEVICE FROM HOOP/TRAY. THE DEVICE WAS PREPPED PER IFU WITH NO ISSUES IDENTIFIED. IT WAS REPORTED THAT DURING BALLOON INFLATION, THE BALLOON BURST AT 12ATM. ALL FRAGMENTS OF THE BALLOON WERE RETRIEVED. THE DEVICE PASSED THROUGH A PREVIOUSLY DEPLOYED STENT. PHYSICIAN WAS POST DILATING A STENT PLACED. THE BALLOON WAS INFLATED TO 12 ATM WHEN IT RUPTURED. THE BALLOON WAS THEN TAKEN OUT AND A 7 X 20 EVER CROSS BALLOON WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO VESSEL DAMAGE NOTED. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11575437 ↗InjurySep 2, 2020Burst Container or Vessel; Difficult to Remove; Detachment of Device or Device Component; Burst Container or Vessel; Difficult to Remove; Detachment of Device or Device Component
PHYSICIAN INTENDED TO USE AN EVERCROSS PTA BALLOON WITH A 6FR SHEATH AND 0.035 NON-MEDTRONIC GUIDEWIRE DURING TREATMENT OF A 30MM FISTULOGRAM IN THE PATIENT¿S MID RIGHT CEPHALIC VEIN. SLIGHT VESSEL TORTUOSITY IS REPORTED. VESSEL DIAMETER REPORTED AS 7MM. LESION EXHIBITED 50% STENOSIS. NO DAMAGE WAS NOTED TO THE DEVICE PACKAGING PRIOR TO USE. NO ISSUES WERE NOTED WHEN REMOVING THE DEVICE FROM THE PACKAGING. IFU WAS FOLLOWED AND THE DEVICE WAS PREPPED WITHOUT ISSUE. A NON-MEDTRONIC INFLATION DEVICE WAS USED WITH A 25% CONTRAST: 75% SALINE MIX. THE DEVICE WAS NOT PASSED THROUGH A PREVIOUSLY DEPLOYED STENT. NO RESISTANCE WAS NOTED DURING ADVANCEMENT OF THE DEVICE. IT IS REPORTED A CIRCUMFERENTIAL/RADIAL BALLOON BURST OCCURRED AT AN INFLATION PRESSURE OF 13ATM. ONE PRIOR INFLATION HAD BEEN APPLIED TO THE DEVICE. IT IS REPORTED DURING REMOVAL THE BALLOON BECAME STUCK AND A PART OF THE BALLOON AND TIP OF THE CATHETER BROKE OFF AND BECAME STUCK WHERE THE CEPHALIC VEIN BIFURCATES INTO THE CEPHALIC IMBECILIC. A TOURNIQUET WAS APPLIED TO THE UPPER ARM AND AN OPEN INCISION WAS MADE TO REMOVE THE PIECE A BALLOON AND CATHETER. THE PATIENT IS REPORTED TO BE DOING WELL AND NO OTHER INJURY WAS REPO
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10481548 ↗
Other Catheter, angioplasty, peripheral, transluminal devices
- Coyote™ ES H74939135152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal879 reports
- Coyote™ ES H74939135204010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal585 reports
- Coyote™ ES H74939135202010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal437 reports
- Coyote™ ES H74939135304010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal384 reports
- Coyote™ ES H74939135404010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal293 reports
- Coyote™ ES H74939134152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal279 reports
- Coyote™ H74939185202210Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal200 reports
- Coyote™ ES H74939135254010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal127 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.