Skip to content

Chocolate™ CB1415025120OTWRecalls & reported problems

Medtronic, Inc. · PTA CB1415025120 CHOCOLATE 014 V05 · Class 2

All models of Chocolate (17)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00763000500146), received between Mar 30, 2026 and Mar 30, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Deformation Due to Compressive Stress” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Deformation Due to Compressive Stress1
  • Material Deformation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 30, 2026Deformation Due to Compressive Stress; Material Deformation

    IT WAS REPORTED THAT DURING TREATMENT OF A CALCIFIED LESION IN THE MID TO DISTAL PERONEAL ARTERY USING A CHOCOLATE PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY BALLOON CATHETER, THE CATHETER/DELIVERY SYSTEM WAS DEFORMED AND KINKED. MODERATE VESSEL TORTUOSITY AND CALCIFICATION WERE REPORTED. THE DEVICE WAS PREPPED ACCORDING TO INSTRUCTIONS FOR USE WITH NO ISSUES IDENTIFIED. NO EMBOLIC PROTECTION WAS USED, AND THE BALLOON WAS INFLATED WITH A SYRINGE. THERE WERE NO ISSUES NOTED WHEN REMOVING THE DEVICE FROM THE PACKAGING OR HOOP/TRAY, AND NO RESISTANCE WAS ENCOUNTERED WHEN ADVANCING THE DEVICE. THE CHOCOLATE BALLOON CATHETER WAS REPEATEDLY INFLATED THREE TIMES, AND UPON REMOVAL, A CATHETER FRACTURE (KINK) WAS DISCOVERED. THE PROCEDURE WAS COMPLETED, AND THE PATIENT OUTCOME WAS REPORTED AS ALIVE WITH NO INJURY. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT. THERE WAS DAMAGE TO THE NITINOL CAGE. A CATHETER FRACTURE WAS REPORTED BUT REMAINED ATTACHED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24730254 ↗

Other Catheter, angioplasty, peripheral, transluminal devices

All Catheter, angioplasty, peripheral, transluminal devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page