Skip to content

NanoCross™ Elite AB14W050040150 (UDI 00763000758066)Recalls & reported problems

Medtronic, Inc. · PTA AB14W050040150 NANOCROSS 014 V06 · Class 2

All models of NanoCross Elite (31)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
1

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00763000758066), received between Nov 12, 2024 and Nov 12, 2024 — classified as 1 injury.

The most frequently reported specific device problem is “Deflation Problem” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Dec 10, 2024Class IIOpen, Classified

    There is the potential for in-vivo balloon deflation issues, including difficulty or inability to deflate the balloon in specific lots.

    Z-0904-2025 · Root cause: Process change control · Recall details · FDA record ↗

Most reported problems

Device problems

  • Deflation Problem1
  • Deformation Due to Compressive Stress1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 12, 2024Deflation Problem; Deformation Due to Compressive Stress; Deflation Problem; Deformation Due to Compressive Stress

    A NANOCROSS PTA BALLOON WAS BEING USED FOR TREATMENT OF THE SUPERFICIAL FEMORAL ARTERY. A 6FR NON MEDTRONIC SHEATH WAS USED AND A 0.014" SPIDER GUIDEWIRE. A 4MM SPIDER WAS USED FOR EMBOLIC PROTECTION. IT WAS REPORTED DEFLATION DIFFICULTIES OCCURRED AND A KINK WAS NOTED ON THE BALLOON CATHETER, PROXIMAL TO THE BALLOON. MULTIPLE DRAWS WITH NEGATIVE PRESSURE ON A 20CC SYRINGE WERE USED TO DEFLATE THE BALLOON. DEFLATION TOOK LONGER THAN 10 MINUTES. THE DEVICE WAS SAFELY REMOVED FROM THE PATIENT. ANOTHER MEDTRONIC DEVICE WAS USED TO COMPLETE THE CASE. NO ISSUES REPORTED WITH THIS DEVICE. NO HEALTH CONSEQUENCES OR IMPACT REPORTED FOR THIS PATIENT FOR THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20663075 ↗

Other Catheter, angioplasty, peripheral, transluminal devices

All Catheter, angioplasty, peripheral, transluminal devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page