EverCross™ AB35W08080135 (UDI 00763000766986)Recalls & reported problems
Medtronic, Inc. · PTA AB35W08080135 EVERCROSS 035 V10 · Class 2
All models of EverCross (17)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00763000766986), received between Feb 5, 2025 and Feb 5, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Burst Container or Vessel” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Burst Container or Vessel1
- Device Damaged by Another Device1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 5, 2025Burst Container or Vessel; Device Damaged by Another Device; Burst Container or Vessel; Device Damaged by Another Device
IT WAS REPORTED THAT DURING A PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY PROCEDURE USING THE EVERCROSS 035 BALLOONS, THE BALLOONS BURST DURING THE PROCEDURE AT A PRESSURE OF 8 ATMS ON THE FIRST INFLATION. THE PROCEDURE INVOLVED THE RIGHT PROXIMAL ILIAC ARTERY, WHICH WAS CALCIFIED WITH 80% STENOSIS AND A DIAMETER OF 8 MILLIMETERS. THE DEGREE OF TORTUOSITY WAS MINIMAL. A 6FR NON-MEDTRONIC SHEATH AND A 0.035" NON-MEDTRONIC GUIDEWIRE WERE USED. THE DEVICES WERE PASSED THROUGH A PREVIOUSLY DEPLOYED STENT WITHOUT ENCOUNTERING RESISTANCE. THE BALLOONS WERE INFLATED USING AN INFLATION DEVICE WITH A 50/50 CONTRAST FLUID. THE DEVICES WERE SAFELY REMOVED FROM THE PATIENT, AND THERE WERE NO INJURIES OR INTERVENTIONS ASSOCIATED WITH THE EVENT. THE PHYSICIAN BELIEVES THAT BOTH BALLOONS LIKELY GOT CAUGHT ON THE STRUT OF THE PREVIOUSLY IMPLANTED STENT. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21313209 ↗
Other Catheter, angioplasty, peripheral, transluminal devices
- Coyote™ ES H74939135152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal879 reports
- Coyote™ ES H74939135204010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal585 reports
- Coyote™ ES H74939135202010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal437 reports
- Coyote™ ES H74939135304010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal384 reports
- Coyote™ ES H74939135404010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal293 reports
- Coyote™ ES H74939134152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal279 reports
- Coyote™ H74939185202210Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal200 reports
- Coyote™ ES H74939135254010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal127 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.