Skip to content

EverCross™ AB35W10060080 (UDI 00763000767150)Recalls & reported problems

Medtronic, Inc. · PTA AB35W10060080 EVERCROSS 035 V10 · Class 2

All models of EverCross (17)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00763000767150), received between Feb 13, 2025 and Feb 13, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component1
  • Difficult to Remove1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 13, 2025Difficult to Remove; Detachment of Device or Device Component; Difficult to Remove; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING A PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY USING THE EVERCROSS 035 A BALLOON DILATATION DEVICE, THE BALLOON GOT STUCK OUTSIDE OF THE 7F SHEATH AND SUBSEQUENTLY RIPPED APART INTO THREE PIECES. THE PROCEDURE WAS BEING PERFORMED AT THE AV ACCESS SITE IN THE RIGHT PROXIMAL VEIN. A 7F SHEATH WAS USED. DEVICE PASSED THROUGH A PREVIOUSLY DEPLOYED STENT. SEVERE RESISTANCE ENCOUNTERED WHEN ADVANCING THE DEVICE. EXCESSIVE FORCE WAS NOT USED. AN INFLATION DEVICE WAS USED. 50/50 CONTRAST WAS USED. THE BALLOON DETACHED WITHIN THE VESSEL, CAUSING REMOVAL DIFFICULTIES. THE DETACHED COMPONENT WAS SUCCESSFULLY REMOVED WITHIN THE SHEATH, AND THE DEVICE WAS REMOVED IN TANDEM WITHOUT INJURY OR INTERVENTION. POST PROCEDURE THE BALLOON WAS DESTROYED. THE SURGERY EXPERIENCED A 15-MINUTE DELAY DUE TO THESE ISSUES. THE PROCEDURE WAS COMPLETED USING A NEW DEVICE. THERE WAS NO MEDICATION ADMINISTERED TO THE PATIENT OR ADDITIONAL INTERVENTION REQUIRED IN REMOVING THE DETACHED BALLOON. NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21374544 ↗

Other Catheter, angioplasty, peripheral, transluminal devices

All Catheter, angioplasty, peripheral, transluminal devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page