Vaccess® VA8078Recalls & reported problems

Bard Peripheral Vascular, Inc. · Vaccess® PTA Dilatation Catheter 7 mm x 80 mm, 80 cm Catheter · Class 2

All models of Vaccess (25)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
14
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 14 adverse event reports that list this exact device (DI 00801741059933), received between Feb 26, 2018 and Jul 29, 2025 — classified as 1 injury, 13 malfunctions.

The most frequently reported specific device problem is “Material Rupture” (9 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Rupture9
  • Break4
  • Detachment of Device or Device Component2
  • Entrapment of Device2
  • Retraction Problem2
  • Device Markings/Labelling Problem1
  • Difficult to Remove1
  • Packaging Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions9
  • No Consequences Or Impact To Patient4
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available2

Recent adverse event reports

The 14 most recent of 14 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 29, 2025Break; Difficult to Remove; Material Rupture; Detachment of Device or Device Component; Break; Difficult to Remove; Material Rupture; Detachment of Device or Device Component

    A PATIENT UNDERWENT A PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) PROCEDURE USING THE VACCESS PTA BALLOON CATHETER FOR THROMBECTOMY. DURING THE PROCEDURE, THE BALLON BROKE AT 8 ATM. IT WAS FURTHER REPORTED THAT THE END OF THE BALLOON SEPARATED FROM THE OTHER END WHILE REMOVING. REPORTEDLY, IT WAS ABLE TO REMOVE THE SHEATH BY MAKING A SMALL INCISION AND PULLING THE BALLOON AND THE CATHETER OUT WITH QUITE A BIT OF FORCE. THE CURRENT STATUS OF THE PATIENT IS UNKNOWN.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; No Clinical Signs, Symptoms or Conditions

    MAUDE report 22640760 ↗
  • MalfunctionMay 7, 2025Material Rupture; Material Rupture

    ON (B)(6) 2025, A PATIENT UNDERWENT FOR A PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) PROCEDURE USING THE VACCESS PTA DILATATION CATHETER. DURING THE PROCEDURE, PTA BALLOON WAS ALLEGEDLY NOT INFLATED. IT WAS FURTHER REPORTED THAT THE BALLOON MUST HAVE A HOLE IN IT. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21974459 ↗
  • MalfunctionMar 14, 2025Entrapment of Device; Material Rupture; Entrapment of Device; Material Rupture

    IT WAS REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE, THE PTA BALLOON ALLEGEDLY COULD HAVE GOTTEN CAUGHT ON THE STENT CAUSING A TEAR OR A RIP AT 18 ATM. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21603497 ↗
  • MalfunctionJan 22, 2025Break; Break

    IT WAS REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE, THE PTA BALLOON DILATATION CATHETER ALLEGEDLY BROKE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21206332 ↗
  • MalfunctionApr 18, 2024Entrapment of Device; Material Rupture; Entrapment of Device; Material Rupture

    IT WAS REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE, THE PTA BALLOON ALLEGEDLY RUPTURED AT 2 ATM. IT WAS FURTHER REPORTED THAT THE BALLOON WAS POSSIBLY SNAGGED ON THE STENT. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19131591 ↗
  • MalfunctionJul 23, 2022Packaging Problem; Packaging Problem

    IT WAS REPORTED THAT PRIOR TO AN ANGIOPLASTY PROCEDURE, THE BOX THAT CONTAINED THE BALLOON WAS ALLEGEDLY FOUND BENT IN MULTIPLE SPOTS. THERE WAS NO PATIENT CONTACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15090272 ↗
  • MalfunctionNov 1, 2021Device Markings/Labelling Problem; Device Markings/Labelling Problem

    IT WAS REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE, THE PRODUCT WAS ALLEGEDLY MISLABELED. IT WAS FURTHER REPORTED THAT THE PROCEDURE WAS COMPLETED USING SAME DEVICE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12726217 ↗
  • InjuryAug 3, 2021Material Rupture; Detachment of Device or Device Component; Material Rupture; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE, THE PTA BALLOON ALLEGEDLY RUPTURED. IT WAS FURTHER REPORTED THAT THE BALLOON CAME OFF FROM THE CATHETER AND COULD NOT BE RETRIEVED. ADDITIONAL SURGERY WAS UNDERGONE TO REMOVE THE DEVICE. THE CURRENT STATUS OF THE PATIENT IS UNKNOWN.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 12264625 ↗
  • MalfunctionMar 4, 2021Break; Retraction Problem; Break; Retraction Problem

    IT WAS REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE, THE PTA BALLOON ALLEGEDLY RUPTURED STUCK IN THE SHEATH. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11408688 ↗
  • MalfunctionMar 1, 2021Material Rupture; Material Rupture

    IT WAS REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE IN THE PATIENT'S LEFT UPPER ARM FISTULA, THE PTA BALLOON ALLEGEDLY BUSTED AT 15ATM. IT WAS FURTHER REPORTED THAT ANOTHER DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11395172 ↗
  • MalfunctionOct 9, 2018Retraction Problem; Material Rupture; Retraction Problem; Material Rupture

    IT WAS REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE IN AN AV GRAFT, THE PTA BALLOON ALLEGEDLY RUPTURED, AND SEQUENTIALLY HAD ISSUES RETRACTING THROUGH THE SHEATH. THE BALLOON AND SHEATH WERE REMOVED TOGETHER AS ONE UNIT. ANOTHER DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7950148 ↗
  • MalfunctionAug 15, 2018Material Rupture; Material Rupture

    IT WAS REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE, THE PTA BALLOON ALLEGEDLY RUPTURED CIRCUMFERENTIALLY, AFTER AN ATTEMPT TO GAIN RETROGRADE ACCESS. NO FURTHER TREATMENT WAS NEEDED. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7784999 ↗
  • MalfunctionMar 30, 2018Break; Break

    IT WAS REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE OF A LEFT FOREARM FISTULA, A BREAK WAS ALLEGEDLY IDENTIFIED AT THE JOINT BETWEEN THE CATHETER SHAFT AND THE BALLOON. THE BALLOON WAS EXCHANGED OVER THE GUIDEWIRE FOR ANOTHER THAT WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7386110 ↗
  • MalfunctionFeb 26, 2018Material Rupture; Material Rupture

    IT WAS REPORTED THAT THE PTA BALLOON CATHETER ALLEGEDLY RUPTURED AT 4 ATM. THERE WAS NO REPORTED RETRACTION DIFFICULTY THROUGH THE SHEATH. REPORTEDLY, ANOTHER BALLOON CATHETER WAS EXCHANGED OVER THE GUIDEWIRE AND THE PROCEDURE WAS COMPLETED. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7298185 ↗

Other Catheter, angioplasty, peripheral, transluminal devices

All Catheter, angioplasty, peripheral, transluminal devices →