EverCross™ AB35W08040135 (UDI 00821684062050)Recalls & reported problems
Ev3, Inc · PTA AB35W08040135 EVERCROSS 035 V05 · Class 2
All models of EverCross (114)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00821684062050), received between Aug 14, 2018 and Feb 27, 2020 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Burst Container or Vessel” (2 reports).
1 other recall cover devices cleared under the same FDA submission (K103322); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Burst Container or Vessel2
- Detachment of Device or Device Component1
- Difficult to Remove1
Patient problems
- No Consequences Or Impact To Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryFeb 27, 2020Burst Container or Vessel; Difficult to Remove; Detachment of Device or Device Component; Burst Container or Vessel; Difficult to Remove; Detachment of Device or Device Component
PHYSICIAN USED AN EVERCROSS PTA BALLOON OVER A NON-MEDTRONIC WIRE DURING TREATMENT OF THE PATIENT¿S LEFT ILIAC ARTERY. ACCESS WAS FROM THE LEFT UPPER LIMB. INFLATION WAS PERFORMED BELOW RBP TO A MAXIMUM OF 13 ATM. DURING BALLOON INFLATION, THE BALLOON IS REPORTED TO HAVE BURST. DURING REMOVAL OF THE BALLOON WHEN IT REACHED THE END OF THE SHEATH IT SNAPPED, RESULTING IN APPROXIMATELY 80% OF THE BALLOON REMAINING TRAPPED IN THE ARTERY. UNSUCCESSFUL ATTEMPTS WERE MADE WITH A SNARE TO REMOVE THE DETACHED PORTION. THE PROCEDURE WAS ABANDONED, AND THE PATIENT WAS TAKEN TO VASCULAR THEATRE FOR SURGICAL REMOVAL. NO PATIENT INJURY REPORTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9762531 ↗MalfunctionAug 14, 2018Burst Container or Vessel; Burst Container or Vessel
THE PHYSICIAN WAS ATTEMPTING TO USE AN EVERCROSS BALLOON DILATION CATHETER TO TREAT A MODERATELY CALCIFIED MID RIGHT COMMON ILIAC ARTERY. THE VESSEL HAD LITTLE TORTUOSITY AND THE LESION HAD RESULTED IN 90% STENOSIS. THE DEVICE WAS PREPPED WITH NO ISSUES IDENTIFIED. THERE WAS NO RESISTANCE ENCOUNTERED ADVANCING THE DEVICE AND IT DID NOT PASS THROUGH A PREVIOUSLY DEPLOYED STENT. DURING THE FIRST BALLOON INFLATION AT 7ATM THE BALLOON BURST. THE PROCEDURE USED A NON-MDT INFLATION DEVICE. THERE WERE NO BALLOON FRAGMENTS. ALL OF DEVICE WAS WITHDRAWN FROM THE PATIENT WITHOUT INTERVENTION. THE ARTERY WAS STENTED WITH A 10X40 PROTEGE, AND POST DILATED WITH A COMPETITIVE BALLOON TO COMPLETE THE PROCEDURE. THE USE OF THE PROTEGE WAS PLANNED. NO PATIENT INJURY WAS REPORTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7780070 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K103322. One submission often covers many models, so check the product and lot details in each record.
- Z-1489-2014 · Apr 9, 2014 · Terminatedev3 EverCross 0.035" OTW PTA Dilatation Catheter, 6mm x 120mm x 135cm, REF: AB35W06120135. and ev3 EverCross 0.035" OTW PTA Dilatation Catheter, 6mm x 40mm x, 80cm REF: AB35W
Other Catheter, angioplasty, peripheral, transluminal devices
- Coyote™ ES H74939135152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal879 reports
- Coyote™ ES H74939135204010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal585 reports
- Coyote™ ES H74939135202010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal437 reports
- Coyote™ ES H74939135304010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal384 reports
- Coyote™ ES H74939135404010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal293 reports
- Coyote™ ES H74939134152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal279 reports
- Coyote™ H74939185202210Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal200 reports
- Coyote™ ES H74939135254010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal127 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page