Miller G03421Recalls & reported problems
Cook Incorporated · Miller Double Mushroom Biliary Stent Set · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00827002034211), received between Apr 19, 2018 and Apr 19, 2018 — classified as 2 injuries.
The most frequently reported specific device problem is “Material Fragmentation” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Material Fragmentation1
- Material Separation1
Patient problems
- No Code Available2
- Cellulitis1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryApr 19, 2018Material Separation; Material Separation
IT WAS REPORTED A MILLER DOUBLE MUSHROOM BILIARY STENT SET WAS DIFFICULT TO REMOVE IN AN ANTEGRADE DIRECTION WHILE STENTING THE BILE DUCT DUE TO CHOLANGITIS STRICTURE OF THE COMMON BILE DUCT. A SECTION FOR THE DEVICE REMAINED IN THE PATIENT AND WAS REMOVED IN TO THE SMALL BOWEL TO PASS. AS REPORTED, THE PATIENT DID NOT REQUIRE AN ADDITIONAL PROCEDURE OR EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.
Patient problems: No Code Available
MAUDE report 7443743 ↗InjuryApr 19, 2018Material Fragmentation; Material Fragmentation
IT WAS REPORTED DURING A BILIARY STENT REMOVAL THROUGH A PERCUTANEOUS ACCESS PORT, THE MILLER DOUBLE MUSHROOM BILIARY STENT WAS STUCK IN THE BILIODIGESTIVE ANASTOMOSIS AND DIFFICULT TO REMOVE. A SMALL PART OF THE STENT REMAINED IN THE SUBCUTANEOUS TISSUE WHICH REQUIRED A SMALL SKIN INCISION BE MADE TO REMOVE THIS FRAGMENT. AS REPORTED, THE PATIENT DEVELOPED EXTENSIVE CELLULITIS IN THE ABDOMINAL REGION AND REQUIRED INTRAVENOUS ANTIBIOTICS FOR AN EXTENDED PERIOD OF TIME.
Patient problems: Cellulitis; No Code Available
MAUDE report 7442516 ↗
Other CATHETER, BILIARY, DIAGNOSTIC devices
- Hurricane™ RX M00545900Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls1 death705 reports
- MUSTANG™ H74939171060470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC384 reports
- CRE™ PRO M00558710Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC1 recall284 reports
- Hurricane™ RX M00545920Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls211 reports
- MUSTANG™ H74939171070470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC265 reports
- MUSTANG™ H74939171050470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC212 reports
- Hurricane™ RX M00545940Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls109 reports
- MUSTANG™ H74939171100470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC203 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page