Cook G14255Recalls & reported problems
Cook Incorporated · Disposable Two-Part Trocar Needle · Class U
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00827002142558), received between Sep 18, 2023 and Sep 18, 2023 — classified as 1 injury.
The most frequently reported specific device problem is “Difficult to Remove” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Difficult to Remove1
- Material Separation1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 18, 2023Difficult to Remove; Material Separation; Difficult to Remove; Material Separation
IT WAS REPORTED THAT A HIWIRE NITINOL HYDROPHILIC WIRE GUIDE WAS DIFFICULT TO REMOVE FROM A DISPOSABLE TWO-PART TROCAR NEEDLE. THE WIRE GUIDE WAS PLACED UNDER X-RAY THROUGH THE SHEATH OF THE TROCAR NEEDLE DURING A LEFT SUPINE PERCUTANEOUS NEPHROLITHOTOMY PROCEDURE FOR AN UNKNOWN PATIENT. ACCESS TO THE KIDNEY WAS ACHIEVED, AND THE INNER TROCAR OF THE NEEDLE WAS REMOVED BEFORE PLACING THE WIRE GUIDE THROUGH THE OUTER SHEATH OF THE NEEDLE. NO RESISTANCE WAS REPORTED. THE WIRE WAS MANIPULATED IN ORDER TO PLACE THE WIRE DOWN THE URETER. HOWEVER, IN THIS PROCESS THE WIRE WOULD NOT MOVE ANY MORE. ATTEMPTED WITHDRAW OF THE WIRE GUIDE WAS UNSUCCESSFUL. THEREFORE, THEY ATTEMPTED TO PULL THE WIRE THROUGH VIA A RETROGRADE APPROACH USING ANOTHER MANUFACTURER'S DISPOSABLE URETEROSCOPE AND A COOK FLEXOR URETERAL ACCESS SHEATH. FURTHER ATTEMPTS TO WITHDRAW THE WIRE VIA A NEEDLE SHEATH REVEALED THE COATING HAD BEEN STRIPPED FROM THE WIRE LEAVING A BARE WIRE SECTION. DILATION WAS CONTINUED WITH FASCIAL DILATOR SETS FOLLOWED BY A NEPHROSTOMY BALLOON CATHETER. A DUAL LUMEN URETERAL ACCESS CATHETER WAS USED TO EXCHANGE THE WIRE FOR A NEW WIRE GUIDE. WHEN THE NEEDLE AND SHEATH WERE PUT BACK TOGETHER ON
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17770546 ↗
Other CATHETER, NEPHROSTOMY devices
- Cook G09501Cook Incorporated · CATHETER, NEPHROSTOMY280 reports
- Dawson Mueller G09705Cook Incorporated · CATHETER, NEPHROSTOMY2 deaths215 reports
- Cook G09497Cook Incorporated · CATHETER, NEPHROSTOMY129 reports
- Dawson Mueller G11020Cook Incorporated · CATHETER, NEPHROSTOMY100 reports
- Cook G09502Cook Incorporated · CATHETER, NEPHROSTOMY86 reports
- NephroMax Kit M0062101180Boston Scientific Corporation · CATHETER, NEPHROSTOMY1 recall25 reports
- NephroMax Kit M0062101600Boston Scientific Corporation · CATHETER, NEPHROSTOMY1 recall11 reports
- Dawson Mueller G13768Cook Incorporated · CATHETER, NEPHROSTOMY59 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.