Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00827002219823), received between Aug 10, 2025 and Aug 10, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Off-Label Use” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Off-Label Use1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 10, 2025Off-Label Use; Off-Label Use
OPERATOR HAD DIFFICULTY DEPLOYING STENT OVER WIRE GUIDE AND AS STENT WAS VERY STIFF AND WAS BUCKLING UNDER PRESSURE. I HAVE BEEN ADVISED BY THE DOCTOR THAT DURING A PROCEDURE ON (B)(6) 2025, THAT THE 10FR X 9MM ZIMMON STENT WAS TOO STIFF. WHEN TRYING TO STRAIGHTEN OVER STIFF GUIDEWIRE, THE STENT BUCKLES, AT RISK OF FRACTURE, RATHER THAN BEING MALLEABLE. A 7FR X 12MM ZIMMON BILIARY STENT WAS USED INSTEAD. COOK CELECT PLATINUM VENA CAVA SET FOR FEMORAL AND JUGULAR VEIN APPROACH. 1. DOES THE COMPLAINT RELATE TO DEVICE REPLACEMENT, DEVICE REMOVAL OR WAS IT AN OBSERVATION MADE PRIOR TO PATIENT CONTACT? DEVICE PLACEMENT. 2. WHAT WAS THE TARGET LOCATION FOR THE STENT? GALL BLADDER. 3. PLEASE DESCRIBE THE STORAGE CONDITIONS OF THE DEVICE PRIOR TO USE ESPECIALLY THOSE PERTAINING TO TEMPERATURE AND LIGHT EXPOSURE. AS PER IFU¿S. 4. WHAT IS THE REORDER NUMBER, DIAMETER AND LENGTH OF THE WIRE GUIDE THAT WAS USED WITH THIS DEVICE IN THIS PROCEDURE? TERUMO 0.0035 STIFF WIRE GUIDE. 5. WAS THE WIRE GUIDE LUBRICATED PRIOR TO USE? YES. 6. WAS THE WIRE GUIDE INSPECTED FOR DAMAGE PRIOR TO USE? YES. 7. WAS THE DEVICE AT THE CENTRE OF THE COMPLAINT INSPECTED FOR DAMAGE PRIOR TO USE? NO. 8. WERE PREVIOUS
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22768299 ↗
Other CATHETER, BILIARY, DIAGNOSTIC devices
- Hurricane™ RX M00545900Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls1 death705 reports
- MUSTANG™ H74939171060470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC384 reports
- CRE™ PRO M00558710Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC1 recall284 reports
- Hurricane™ RX M00545920Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls211 reports
- MUSTANG™ H74939171070470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC265 reports
- MUSTANG™ H74939171050470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC212 reports
- Hurricane™ RX M00545940Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls109 reports
- MUSTANG™ H74939171100470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC203 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page