GRAVITY 86TA2027Recalls & reported problems

Wright Medical Technology, Inc. · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00840420165947), received between Mar 29, 2022 and Mar 29, 2022 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Break2
  • Fracture2

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 29, 2022Break; Fracture; Break; Fracture

    IT WAS REPORTED THAT THE TIP OF THE WRIGHT MEDICAL TITANIUM GRAVITY SCREWDRIVER BROKE OFF IN THE SCREW ONCE IMPLANTED. THIS HAPPENED TWICE IN THE SAME CASE WITH TWO DIFFERENT ANCHORS. WITH THE FIRST ANCHOR, IT WAS RIGHT AS THE SCREW PORTION OF THE DEVICE WAS ADVANCED TO BE FLUSH WITH THE BONE. THERE WAS A SNAP AND IT WAS NOTED THAT THE SCREW DRIVER WAS BROKEN OFF IN THE CANNULATED PORTION OF THE SCREW. FOR THE SECOND ANCHOR, IT WAS ADVANCED FLUSH WITH THE BONE, HOWEVER THE SURGEON WANTED TO GIVE IT AN ADDITIONAL TURN TO FULLY SEAT IT. WHEN SHE RE-INSERTED THE SCREW DRIVER TO ADVANCE THE SCREW FURTHER, THE DRIVER AGAIN BROKE OFF IN THE CANNULATED PORTION OF THE SCREW.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13943696 ↗
  • MalfunctionMar 29, 2022Break; Fracture; Break; Fracture

    IT WAS REPORTED THAT THE TIP OF THE WRIGHT MEDICAL TITANIUM GRAVITY SCREWDRIVER BROKE OFF IN THE SCREW ONCE IMPLANTED. THIS HAPPENED TWICE IN THE SAME CASE WITH TWO DIFFERENT ANCHORS. WITH THE FIRST ANCHOR, IT WAS RIGHT AS THE SCREW PORTION OF THE DEVICE WAS ADVANCED TO BE FLUSH WITH THE BONE. THERE WAS A SNAP AND IT WAS NOTED THAT THE SCREW DRIVER WAS BROKEN OFF IN THE CANNULATED PORTION OF THE SCREW. FOR THE SECOND ANCHOR, IT WAS ADVANCED FLUSH WITH THE BONE, HOWEVER THE SURGEON WANTED TO GIVE IT AN ADDITIONAL TURN TO FULLY SEAT IT. WHEN SHE RE-INSERTED THE SCREW DRIVER TO ADVANCE THE SCREW FURTHER, THE DRIVER AGAIN BROKE OFF IN THE CANNULATED PORTION OF THE SCREW.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13943680 ↗

Other FASTENER, FIXATION, NONDEGRADABLE, SOFT TISSUE devices